Development of a Homemade Chopper and Its Application to
Photoacoustic Spectroscopy for CO2 Measurement |
PENG Jie1, 2, WANG Rui-feng1, CAO Yuan1*, MEI Jiao-xu1, WANG Gui-shi1, LIU Kun1, GAO Xiao-ming1, 2, CHENG Gang3 |
1. Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
2. University of Science and Technology of China, Hefei 230026, China
3. State Key Laboratory of Ming Response and Disaster Prevention and Control in Deep Coal Mines (Anhui University of Science and Technology), Huainan 232001, China
|
|
|
Abstract In photoacoustic spectroscopy, periodic modulation of light sources is one of the necessary conditions for generating photoacoustic signals. The modulation can only be realized using mechanical choppers for some light sources, such as infrared radiation sources applied in broadband photoacoustic spectroscopy. However, a commercial chopper is unsuitable for miniaturized photoacoustic spectroscopy instruments due to its large size and high cost. In this paper, we carried out the design and development of a homemade chopper and its application to carbon dioxide (CO2) detection by photoacoustic spectroscopy. The chopper control circuit was designed based on the STM32 microcontroller technology, and a comparison experiment between the homemade chopper and the commercial chopper was conducted. The experimental results showed that the photoacoustic signals produced by both had a good consistency, verifying the feasibility and reliability of the homemade chopper, which can satisfy the application requirements of photoacoustic spectroscopy. Then, the research of photoacoustic spectroscopy for measuring CO2 was carried out based on the homemade chopper, and the effect of humidity on the CO2 photoacoustic signal was analyzed. It has been shown that water vapor significantly accelerates the molecular relaxation rate of CO2, thus improving the amplitude of the photoacoustic signal of CO2. The Allan deviation result showed that the detection sensitivity for CO2 of the photoacoustic spectroscopy system was found to be 5 μL·L-1 at an average time of 200 s. Compared with the CO2 before humidification, the minimum detection limit of CO2 was improved by a factor of 2.4 after humidification. The homemade chopper is characterized by easy integration and has reference or application value for developing high-sensitivity photoacoustic spectroscopy instruments.
|
Received: 2023-10-16
Accepted: 2024-01-25
|
|
Corresponding Authors:
CAO Yuan
E-mail: caoyuan@aiofm.ac.cn
|
|
[1] Lang B, Breitegger P, Brunnhofer G, et al. Applied Physics B, 2020, 126(4): 64.
[2] Cao Y, Liu K, Wang R, et al. Sensors and Actuators B: Chemical, 2023, 388: 133805.
[3] Ma Y, HuY, Qiao S, et al. Photoacoustics, 2022, 25: 100329.
[4] Menduni G, Zifarelli A, Kniazeva E, et al. Sensors and Acutuators B: Chemical, 2023, 375: 132953.
[5] Dumitras D. C, Petrus M, Bratu A M, et al. Molecules, 2020, 25(7): 1728.
[6] Yin X, Dong L, Wu H, et al. Sensors and Actuators B: Chemical, 2017, 247: 329.
[7] Liu K, Yi H, Kosterev A A, et al. Review of Scientific Instruments, 2010, 81(10): 103103.
[8] Moser H, Lendl B. Applied Physics B, 2016, 122(4): 83.
[9] Liu K, Cao Y, Wang G, et al. Sensors and Actuators B: Chemical, 2018, 277: 571.
[10] Bruhns H, Marianovich A, Wolff M. International Journal of Thermophysics, 2014, 35(12): 2292.
[11] Cao Y, Liu Q, Wang R, et al. Photoacoustics, 2021, 21: 100229.
[12] Liu K, Mei J, Zhang W. Sensors and Actuators B: Chemical, 2017, 251: 632.
[13] Cao Y, Wang R, Peng J, et al. Photoacoustics, 2021, 24: 100303.
[14] Qiao S, Ma P, Tsepelin V, et al. Optics Letters, 2023, 48(2): 419.
[15] Lang Z, Qiao S, Ma Y. Light: Advanced Manufacturing, 2023, 4: 23.
[16] Borri S, Patimisco P, Sampaolo A, et al. Applied Physics Letters, 2013, 103(2): 021105.
[17] Selvaraj R, Vasa N J, Nagendra S M S. Analytical Chemistry, 2019, 91(22): 14239.
[18] Chen K, Liu S, Zhang B, et al. Optics and Lasers in Engineering, 2020, 124: 105844.
[19] Liu L, Mandelis A, Huan H, et al. Vibrational Spectroscopy, 2016, 87: 94.
[20] Bell A G. American Journal of Science, 1880, s3-20(118): 305.
[21] Wysocki G., Kosterev A A, Tittel F K. Applied Physics B, 2006, 85: 301.
|
[1] |
ZHANG Xiao-dong1, KANG Hong-dong1, LI Bing-hui2, ZHANG Shuo1*, HAN Lei1. Spectroscopic Differences in Different Solvent Pretreated Coals in the Presence of ScCO2 and Their Mechanisms[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(09): 2657-2666. |
[2] |
LI Rong-yi, ZHU Hai-long*. Temperature Measurement of Atmospheric-Pressure CO2 Microwave
Discharge With Optical Emission Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(03): 688-692. |
[3] |
LIU Zhao-hai1, AN Xin-chen1, 3, TAO Zhi1, 2, LIU Xiang1, 2*. Multicomponent Trace Gas Detecting and Identifying System Based on MEMS-FPI on-Chip Spectral Device[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(02): 359-366. |
[4] |
XU Qiu-yi1, 3, 4, ZHU Wen-yue3, 4, CHEN Jie2, 3, 4, LIU Qiang3, 4 *, ZHENG Jian-jie3, 4, YANG Tao2, 3, 4, YANG Teng-fei2, 3, 4. Calibration Method of Aerosol Absorption Coefficient Based on
Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 88-94. |
[5] |
ZHENG Hong-quan, DAI Jing-min*. Research Development of the Application of Photoacoustic Spectroscopy in Measurement of Trace Gas Concentration[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 1-14. |
[6] |
FU Wen-xiang, DONG Li-qiang, YANG Liu*. Research Progress on Detection of Chemical Warfare Agent Simulants and Toxic Gases by Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3653-3658. |
[7] |
CHENG Gang1, CAO Ya-nan1, TIAN Xing1, CAO Yuan2, LIU Kun2. Simulation of Airflow Performance and Parameter Optimization of
Photoacoustic Cell Based on Orthogonal Test[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3899-3905. |
[8] |
ZHU Hua-dong1, 2, 3, ZHANG Si-qi1, 2, 3, TANG Chun-jie1, 2, 3. Research and Application of On-Line Analysis of CO2 and H2S in Natural Gas Feed Gas by Laser Raman Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3551-3558. |
[9] |
CHEN Tu-nan1, 2, LI Kang1, QIU Zong-jia1, HAN Dong1, 2, ZHANG Guo-qiang1, 2*. Simulation Analysis and Experiment Verification of Insulating Material-Based Photoacoustic Cell[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2922-2927. |
[10] |
JIN Hua-wei1, 2, 3, WANG Hao-wei1, 2, LUO Ping1, 2, FANG Lei1, 2. Simulation Design and Performance Analysis of Two-Stage Buffer
Photoacoustic Cell[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(08): 2375-2380. |
[11] |
LI Zhen-gang1, 2, SI Gan-shang1, 2, NING Zhi-qiang1, 2, LIU Jia-xiang1, FANG Yong-hua1, 2*, CHENG Zhen1, 2, SI Bei-bei1, 2, YANG Chang-ping1, 2. Research on Long Optical Path and Resonant Carbon Dioxide Gas
Photoacoustic Sensor[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(01): 43-49. |
[12] |
ZHA Ling-ling1, 2, 3, WANG Wei2*, XIE Yu1, SHAN Chang-gong2, ZENG Xiang-yu2, SUN You-wen2, YIN Hao2, HU Qi-hou2. Observation of Variations of Ambient CO2 Using Portable FTIR
Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1036-1043. |
[13] |
SU Jing-ming1, 2, 3, ZHAO Min-jie1, ZHOU Hai-jin1, YANG Dong-shang1, 2, HONG Yan3, SI Fu-qi1*. On-Orbit Degradation Monitoring of Environmental Trace Gases Monitoring Instrument Based on Level 0 Data[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(03): 686-691. |
[14] |
FU Juan, MO Jia-mei, YU Yi-song, ZHANG Qing-zong, CHEN Xiao-li, CHEN Pei-li, ZHANG Shao-hong, SU Qiu-cheng*. Experimental Study on the Structure Characteristics of CO2 in Gas Hydrate by Solid-State Nuclear Magnetic Resonance and Raman Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 464-469. |
[15] |
WANG Qi, WANG Shi-chao, LIU Tai-yu, CHEN Zi-qiang. Research Progress of Multi-Component Gas Detection by Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(01): 1-8. |
|
|
|
|