Research on Long Optical Path and Resonant Carbon Dioxide Gas
Photoacoustic Sensor |
LI Zhen-gang1, 2, SI Gan-shang1, 2, NING Zhi-qiang1, 2, LIU Jia-xiang1, FANG Yong-hua1, 2*, CHENG Zhen1, 2, SI Bei-bei1, 2, YANG Chang-ping1, 2 |
1. Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
2. University of Science and Technology of China, Hefei 230026, China
|
|
|
Abstract Carbon dioxide (CO2) is the raw material of plant photosynthesis and greenhouse gas. Its excessive emission will affect the ecological environment of animals and plants. Under the background of carbon peaking and carbon neutrality, it is of great significance to develop high-sensitivity CO2 detection devices. In order to monitor the change of CO2 concentration in the atmospheric environment, a long optical path and resonant CO2 gas photoacoustic sensor was designed, and a photoacoustic detection setup was built. Adistributed feedback laser (DFB) with a central wavelength of 2 004 nm was used as the excitation light source. The laser entered into a spherical absorption cell made of diffuse reflective material, and multiple reflections occurred in the cell to increase the absorption path of the gas. To reduce the thermal noise generated by the absorption of light energy by the absorption cell, the outside of the cell was wrapped by two aluminum hemispheres with high thermal conductivity. An acoustic tube was coupled with the absorption cell. When the tube worked in the first-order longitudinal resonance mode, the photoacoustic signal was amplified and reached the maximum at the end of the tube. The CO2 relaxation rate was greatly accelerated, and the thermal, acoustic conversion efficiency was improved by saturated humidifying the sample, which further amplified the photoacoustic signal. The photoacoustic signal produced by the humidified sample was about 2.1 times that of the dry sample. The photoacoustic detection setup was calibrated with a series of wet CO2 samples, and the results showed a good linear relationship between photoacoustic signals and concentrations. On this basis, the accuracy and stability of the setup were verified through the detection experiment of standard gas. Allan variance was used to evaluate the detection sensitivity of the setup under long-time operation. When the average time was 865 s, the detection sensitivity was ~0.35×10-6. Compared with the traditional T-type photoacoustic cell, the optical path was increased by~20 times, and the photoacoustic signal was amplified by ~6 times. The setup was used to detect CO2 in the outdoor environment for 10 hours, and the average concentration of outdoor CO2 was ~381×10-6. In conclusion, due to the combination of a long optical path, acoustic resonance and humidified samples, the photoacoustic signal of CO2 was effectively increased, which provided a relevant reference for the design of gas photoacoustic sensor and detection setup.
|
Received: 2021-11-23
Accepted: 2022-03-28
|
|
Corresponding Authors:
FANG Yong-hua
E-mail: yhfang@aiofm.ac.cn
|
|
[1] CHEN Ke, YUAN Shuai, GONG Zhen-feng, et al(陈 珂,袁 帅,宫振峰,等). Acta Optica Sinica(光学学报), 2018, 38(3): 0328015.
[2] CHEN Ying, GAO Guang-zhen, CAI Ting-dong(陈 颖,高光珍,蔡廷栋). Chinese Journal of Lasers(中国激光), 2017, 44(5): 0511001.
[3] Mustafa A, Lougou B G, Shuai Y, et al. Journal of Energy Chemistry, 2020, 49: 96.
[4] LI Ming-xing, CHEN Bing, RUAN Jun, et al(李明星,陈 兵,阮 俊,等). Optics and Precision Engineering(光学精密工程), 2020, 28(7): 1424.
[5] Huber J, Weber C, Eberhardt A, et al. Procedia Engineering, 2016, 168: 3.
[6] ZHANG Jian-feng, PAN Sun-qiang, LIN Xiao-lu, et al(张建锋,潘孙强,林晓露,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2016, 36(1): 1.
[7] Liu K, Mei J, Zhang W, et al. Sensors and Actuators B: Chemical, 2017, 251: 632.
[8] Qiao S, Qu Y, Ma Y, et al. Sensors, 2019, 19(19): 4187.
[9] ZHANG Jia-wei, TAN Zhi-qiang, YANG Chun-mei, et al(张佳薇,谈志强,杨春梅,等). Forest Engineering(森林工程), 2021, 37(6): 62.
[10] Rouxel J, Coutard J G, Gidon S, et al. Sensors and Actuators B: Chemical, 2016, 236: 1104.
[11] Chen K, Zhang B, Liu S, et al. Sensors and Actuators A: Physical, 2019, 290: 119.
|
[1] |
ZHENG Hong-quan, DAI Jing-min*. Research Development of the Application of Photoacoustic Spectroscopy in Measurement of Trace Gas Concentration[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 1-14. |
[2] |
XU Qiu-yi1, 3, 4, ZHU Wen-yue3, 4, CHEN Jie2, 3, 4, LIU Qiang3, 4 *, ZHENG Jian-jie3, 4, YANG Tao2, 3, 4, YANG Teng-fei2, 3, 4. Calibration Method of Aerosol Absorption Coefficient Based on
Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 88-94. |
[3] |
FU Wen-xiang, DONG Li-qiang, YANG Liu*. Research Progress on Detection of Chemical Warfare Agent Simulants and Toxic Gases by Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3653-3658. |
[4] |
CHENG Gang1, CAO Ya-nan1, TIAN Xing1, CAO Yuan2, LIU Kun2. Simulation of Airflow Performance and Parameter Optimization of
Photoacoustic Cell Based on Orthogonal Test[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3899-3905. |
[5] |
CHEN Tu-nan1, 2, LI Kang1, QIU Zong-jia1, HAN Dong1, 2, ZHANG Guo-qiang1, 2*. Simulation Analysis and Experiment Verification of Insulating Material-Based Photoacoustic Cell[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2922-2927. |
[6] |
JIN Hua-wei1, 2, 3, WANG Hao-wei1, 2, LUO Ping1, 2, FANG Lei1, 2. Simulation Design and Performance Analysis of Two-Stage Buffer
Photoacoustic Cell[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(08): 2375-2380. |
[7] |
WANG Qi, WANG Shi-chao, LIU Tai-yu, CHEN Zi-qiang. Research Progress of Multi-Component Gas Detection by Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(01): 1-8. |
[8] |
WANG Run-yu1, DONG Da-ming1,2, YE Song1*, JIAO Lei-zi1,2. Measurement of Volatile Compounds Released From Plastic Using[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3039-3044. |
[9] |
REN Zhong1, 2*, LIU Tao1, LIU Guo-dong1, 2. Classification and Identification of Real or Fake Blood Based on OPO Pulsed Laser Induced Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2734-2741. |
[10] |
WAN Liu-jie1, 2, ZHEN Chao3, QIU Zong-jia1, LI Kang1, MA Feng-xiang3, HAN Dong1, 2, ZHANG Guo-qiang1, 2*. Research of High Precision Photoacoustic Second Harmonic Detection Technology Based on FFT Filter[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 2996-3001. |
[11] |
CHEN Jie1, 2, 3, QIAN Xian-mei1, 3, LIU Qiang1, 3*, ZHENG Jian-jie1, 2, 3, ZHU Wen-yue1, 3, LI Xue-bin1, 3. Research on Optical Absorption Characteristics of Atmospheric Aerosols at 1 064 nm Wavelength[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 2989-2995. |
[12] |
XIE Ying-chao1,2, WANG Rui-feng1,2, CAO Yuan1,2, LIU Kun1*, GAO Xiao-ming1,2. Research on Detecting CO2 With Off-Beam Quartz-Enhanced Photoacoustic Spectroscopy at 2.004 μm[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(09): 2664-2669. |
[13] |
CHENG Gang1, CAO Ya-nan1, TIAN Xing1, CAO Yuan2, LIU Kun2*. Influence of Photoacoustic Cell Geometrical Shape on the Performance of Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(08): 2345-2351. |
[14] |
WANG Qiao-yun, YIN Xiang-yu, YANG Lei, XING Ling-yu. Geometrical Optimization of Resonant Ellipsoidal Photoacoustic Cell in Photoacoustic Spectroscopy System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(05): 1351-1355. |
[15] |
LIU Li-xian1, 2, 3, HUAN Hui-ting1, 2, Mandelis Andreas2, SHAO Xiao-peng1*. Multiple Dissolved Gas Analysis in Transformer Oil Based on Fourier Transform Infrared Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(03): 684-687. |
|
|
|
|