A Novel Compensation Method of Gas Absorption Spectrum Based on Time-Sharing Scanning Spectra and Double Gas Cell Switching |
REN Shuang-zan1, WANG Jing-wei2, GAO Liang-liang2, ZHU Hong-mei1, WU Hao1, LIU Jing1, TANG Xiao-jun2*, WANG Bin2 |
1. State Grid Shaanxi Electric Power Research Institute, Xi’an 710100, China
2. State Key Laboratory of Electrical Insulation &Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China |
|
|
Abstract Aiming at the interference caused by the gas in the air gap between the gas cell and the spectrometer, as well as the baseline drift and distortion in the application of Fourier infrared spectroscopy on-line analysis of dissolved gas in transformer oil, a new method of gas absorption spectrum compensation based on time-sharing scanning with two gas cell, was proposed. Based on the traditional single-gas cell measurement, a background gas cell is added that is the same as the structure, size, and other parameters of the measurement gas cell. The background gas cell is filled with nitrogen, and the measurement gas cell is filled with the sample gas to be measured. Besides, the controller is used to realize the switching control of the background gas cell and the measurement gas cell. However, the spectrum processed by the conventional absorbance calculation formula has unknown absorption peaks in the wavenumber range of 1 100 to 1 200 cm-1. There is a severe baseline drift phenomenon, which indicates that the calculation method is no longer suitable for double gas cells. Therefore, in order to eliminate the adverse effect of the inconsistency of the parameters between the two gas cells, especially the difference in the filter characteristics of the window, a new method for calculating the gas absorption absorbance spectrum based on the double gas cell time-division scanning is further proposed, which was proved to eliminate unknown absorption peak and baseline drift, and the drift value decrease from 0.3 to 0.005. Finally, a transformer oil sample was obtained at a substation in Shaanxi, and the corresponding gas samples were obtained after degassing treatment. Conventional single-cell scanning method (group 1), two-gas cell compensation method (group 2), and gas chromatography (group 3) were used for experiments. The results show that methane concentration in group 1 is always more significant than that in group 2. At the same time, the carbon dioxide concentration in group 1 is always greater than the carbon dioxide concentration in group 2. The obvious difference in such analysis results is most likely due to the influence of the air gap between the spectrometer and the gas cell. On the whole, compared with group 1, the analysis results of group 2 are closer to those of gas chromatography. In summary, the new gas absorption spectrum compensation method based on double gas cell switching time-sharing scanning proposed in this paper can effectively solve the problem of spectral baseline drift and distortion. In gas analysis, this method can eliminate the influence of interfereing gas between the gas cell and the spectrometer, and obtain more accurate analysis results.
|
Received: 2020-02-16
Accepted: 2020-06-08
|
|
Corresponding Authors:
TANG Xiao-jun
E-mail: xiaojun_tang@xjtu.edu.cn
|
|
[1] CONG Ri-li,ZHAO Ming-yu,ZHOU Yang(丛日立,赵明宇,周 洋). Electrical Measurement & Instrumentation(电测与仪表), 2019, 56(22): 84.
[2] International Electrotechnical Commission. IEC Std,60599 Guide to the Interpretation of Dissolved and Free Gases Analysis. Geneva:IEC Central Office,2007.
[3] ZHAO An-xin, TANG Xiao-jun, WANG Er-zhen, et al(赵安新,汤晓君,王尔珍,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2013, 33(9): 2407.
[4] Tang Xiaojun, Zhang Feng, Wang Wenjing, et al. Spectroscopy Letters, 2018, 51(3): 134.
[5] Zhao Anxin, Tang Xiaojun, Li Wendong, et al. Spectroscopy Letters, 2015,48(3): 274.
[6] Ni Z,Hu C,Feng F. Chinese Journal of Pharmaceutical Analysis,2008, 28: 824.
[7] Bertinetto C G,Vuorinen T. Applied Spectroscopy, 2014, 68: 155.
[8] Qian F,Wu Y,Hao P. Optics and Laser Technology, 2017, 96: 202.
[9] Lan Tiange,Fang Yonghua,Xiong Wei,et al. Chinese Optics Letters,2007, 5(10): 613.
[10] Zhang Zhimin, Chen Shan, Liang Yizeng. Analyst, 2010, 135(5): 1138.
[11] Peng Jiangtao, Peng Silong, Xie Qiong, et al. Analytica Chimica Acta , 2011, 690: 162.
[12] Sung-June Baek, Aaron Park, Young-Jin Ahn, et al. Analyst, 2015, 140: 250.
[13] WEI Zhi-gai, ZHAO Yi-yang, WANG Feng, et al(魏志改, 赵一阳, 王 凤,等). Preparation and Performance Characterization of KBr Polycrystalline Material(KBr多晶料制备及性能表征). Crystal Growth and Materials Branch of China Silicate Society(中国硅酸盐学会晶体生长与材料分会), 2015. |
[1] |
ZHU Hua-dong1, 2, 3, ZHANG Si-qi1, 2, 3, TANG Chun-jie1, 2, 3. Research and Application of On-Line Analysis of CO2 and H2S in Natural Gas Feed Gas by Laser Raman Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3551-3558. |
[2] |
ZHANG Hao-yu1, FU Biao1*, WANG Jiao1, MA Xiao-ling2, LUO Guang-qian1, YAO Hong1. Determination of Trace Rare Earth Elements in Coal Ash by Inductively Coupled Plasma Tandem Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(07): 2074-2081. |
[3] |
HU Bin1, 2, WANG Pei-fang1, 2*, ZHANG Nan-nan3, SHI Yue4, BAO Tian-li1, 2, JIN Qiu-tong1, 2. Effect of pH on Interaction Between Dissolved Organic Matter and Copper: Based on Spectral Features[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1628-1635. |
[4] |
HUANG Jian-lu1, 2,SHEN Tao1*, YANG Yang1, FAN Bo-xiong1. Research on the Selection of False Targets of Natural Objects in Laser
Angle Deception Jamming[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(09): 2963-2968. |
[5] |
LI Huan-tong1, 2, ZHU Zhi-rong1, 2, QIAO Jun-wei1, 2, LI Ning3, YAO Zheng3, HAN Wei1, 2. Molecular Representations of Jurassic-Aged Vitrinite-Rich and
Inertinite-Rich Coals in Northern Shannxi Province by
FTIR, XPS and 13C NMR[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(08): 2624-2630. |
[6] |
ZHENG Pei-chao, LIU Ran-ning, WANG Jin-mei, FENG Chu-hui, HE Yu-tong, WU Mei-ni, HE Yu-xin. Solution Cathode Glow Discharge-Atomic Emission Spectroscopy Coupled With Hydride Generation for Detecting Trace Mercury and Tin in Water[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1139-1143. |
[7] |
XUE Xin-xin, WANG Wen-bin, LUO Xue-hua, ZHANG Yong-fa, ZHAO Chun-mei. FTIR Spectroscopic Characterization of Material Composition in Leaf of Hevea Brasiliensis Seedlings Under Potassium and Magnesium Deficiency[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(01): 74-79. |
[8] |
LI Ai-yang1, FU Liang2*. Study on the Analysis Total As in Bentonite With Microwave Plasma Atomic Emission Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(12): 3671-3675. |
[9] |
ZHOU Peng, WANG Wei-chao, YANG Wei*, JI Rong-hua, LI Min-zan. Effect of Soil Particle Size on Prediction of Soil Total Nitrogen Using Discrete Wavelength NIR Spectral Data[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(12): 3682-3687. |
[10] |
LIU Hong-wei1,3, FU Liang2*. Analysis of Metal Impurity Elements in Li4Ti5O12 Through Microwave Plasma Atomic Emission Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3021-3025. |
[11] |
ZHOU Jing1,2, ZHANG Qing-qing1,2, JIANG Jin-guo2, NIE Qian2, BAI Zhong-chen1, 2*. Study on the Rapid Identification of Flavonoids in Chestnut Rose (Rosa Roxburghii Tratt) by FTIR[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3045-3050. |
[12] |
QIN Yun-hua1,2, GAO Lei3, LI Chao1, LONG Yu-jiao4, ZHU Ming4, CHEN Da2*. On-Line Spectral Analysis of Crotonaldehyde Content in Cigarette Mainstream Smoke[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(08): 2450-2454. |
[13] |
HAN Guang1, 3, WANG Xiao-yan1, CHEN Si-qi1, WANG Hui-quan1, 3, WANG Jin-hai1, 3, ZHAO Zhe2, 3*. Research Progress on Improving the Accuracy of Near Infrared Spectroscopy Detection of Human Blood and Other Complex Solution Components[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(07): 1993-1997. |
[14] |
LIAN Xiao-qin1, 2,LIU Yu1, 2,CHEN Yan-ming1, 2,HUANG Jing1, 2,GONG Yong-gang1, 2,HUO Liang-sheng1, 2. Research on Multi-Peak Spectral Line Separation Method Based on Adaptive Particle Swarm Optimization[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1452-1457. |
[15] |
CHEN Nan1, 2, WANG Yue1, 4, WANG Bo-yu1, 3, XIA Yang1, 2, 4, LIU Tao1, 4*. Research on Numerical Model of Nano-FTIR System Based on COMSOL[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(04): 1125-1130. |
|
|
|
|