光谱学与光谱分析 |
|
|
|
|
|
Spectrofluorometric Detection of Protein with a Novel Hydrophilic Cyanine Dye |
LIN Xu-cong, GUO Liang-qia, LIN Yan-xia, XIE Zeng-hong* |
Chemistry and Engineering College of Fuzhou University, Fuzhou 350002, China |
|
|
Abstract A sensitive fluorescence quantitative determination for bovine serum albumin (BSA) or human serum albumin (HSA) has been developed by using a new hydrophilic cyanine dye 1,1’-sulfonopropyl-3,3,3’,3’-tetramethylindolium-5,5’-disulfonic potassium (STDP) as a fluorescence probe. Using BSA as a representative protein, characteristics of the fluorescence reaction of STDP with protein were investigated. Effects of the concentration of the hydrophilic cyanine dye, pH value of the buffer solution, and ion-intensity of NaCl were also studied as well as the ratio of ethanol. In the citrate-HCl buffer solution, the fluorescence emission wavelength of BSA-STDP system was 562 nm with the maximum excitation wavelength of 548 nm, and the Stokes displacement was 14 nm. With the pH ranging from 1.0 to 2.0, the fluorescence was increasing and up to the maximum at pH 2.0. However, in the pH range of 3.0-5.0,the interaction of BSA and STDP was weakened due to the decrease in positive charge on the BSA chain, which resulted in an observable decrease of the enhancement of the fluorescence intensity. At the optimum pH of 2.0, electrostatic interactions of positive charges of the BSA chain and negative charges on the sulfonic groups of STDP were carried out. The interactions of the indole group of STDP and some active groups of BSA (viz. amido, carboxyl or sulfhydryl) were also achieved, and resulted in the combination of indole group of cyanine dye into the chain of BSA. So the hydrophobic effect and the protection provided by the skeleton chain of BSA were both improved to prevent the fluorescent energy of STDP from losing in the solution, which caused a notable fluorescence increase with an observable shift to the longer emission wavelength. Furthermore, with the augmentation of BSA, the α-helix structure of BSA molecular turned from the unwrapped state to the enfolded state, in favor of restraining free-oscillation of fluorescence probe in the solution and maintaining a high energy transfer efficiency. Such a fact fueled a highly enhancement of the fluorescence too. Besides, effects of the concentration of cyanine dye on the determination of BSA were also investigated. The fluorescence intensity (ΔF) was enhanced with the increase in the quantity of STDP and gained the peak at 1.00 μmol·L-1. However, when STDP ranged from 1.50 to 5.00 μmol·L-1,some negative congregate effects on the nature of cyanine dye might happen and resulted in a too high fluorescence background. A rapid decrease of the fluorescence intensity was observed. The effects of ion-intensity of NaCl and ethanol on the fluorescence of BSA-STDP system were obvious. Though the fluorescence still remained high at the level of NaCl of 0.025mol·L-1,a rapid decrease happen at the level of NaCl from 0.05 to 0.15 mol·L-1. With the addition of ethanol, the dissolvation capacity of both STDP and BSA was improved and their interactions were accelerated. An increasing fluorescence with the augment of ethanol was obtained and the maximum was achieved with the ratio of ethanol at 10%. Influences of coexistent substances such as amino acid, metal ions such as Cu2+, Na+, Ca2+, Mg2+, Al3+ and Fe3+ were also investigated. Most substances had no notable influences on the determination of BSA except Fe3+ and Cu2+ions. Under the optimum conditions, the fluorescence of STDP was enhanced markedly with the addition of the BSA or HSA protein. Good calibration curves of the proteins were obtained in the range of 0.20-15.00 μg·mL-1 for BSA and 0.20-12.00 μg·mL-1 for HSA with detection limits (3σ/K) of 0.01μg·mL-1. Applied to simulant BSA samples, this method was adaptable. And the results were satisfied with good recoveries ranging from 94.5% to 103.3% at the revels of 4.00, 6.00 and 8.00μg·mL-1 respectively.
|
Received: 2006-12-05
Accepted: 2007-02-18
|
|
Corresponding Authors:
XIE Zeng-hong
E-mail: zhxie@fzu.edu.cn
|
|
Cite this article: |
LIN Xu-cong,GUO Liang-qia,LIN Yan-xia, et al. Spectrofluorometric Detection of Protein with a Novel Hydrophilic Cyanine Dye[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(09): 1775-1779.
|
|
|
|
URL: |
https://www.gpxygpfx.com/EN/Y2007/V27/I09/1775 |
[1] CAO Shu-xia, ZHAO Yu-fen (曹书霞,赵玉芬). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2004, 24(10):1197. [2] LIU Dian-mei, LI Shu-ting, ZHAO Shu-lin(刘典梅, 李舒婷, 赵书林). Chinese Journal of Analytical Chemistry(分析化学), 2004, 32(2): 187. [3] HUANG Jian-hua, MA Hong-min, SUN Shu-ting, et al(黄建华, 马洪敏, 孙舒婷, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2006, 26(10):1899. [4] Glunde K, Foss C A, Takagit, et al. Bioconjugate Chem.,2005,16(4):843. [5] SHI Yan, ZHENG Wei-wan, WU Xiao-xing, et al(石 燕, 郑为完, 吴晓星, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2006, 26(9):1653. [6] LI Yong-xin,ZHAO Dan-hua,ZHUO Shu-juan, et al(李永新, 赵丹华, 卓淑娟, 等). Chinese Journal of Analytical Chemistry(分析化学),2003,31(5):638. [7] SUN Wei,HAN Jun-ying,JIAO Kui(孙 伟, 韩军英, 焦 奎). Journal of Analytical Science(分析科学学报),2006,22(2):145. [8] LIN Xu-cong,XIE Zeng-hong,GUO Liang-qia,et al(林旭聪, 谢增鸿, 郭良洽, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2004,24(10):1230. [9] LIU Zhi-gang,ZHU Jian-qi,HUANG Hai-zhen,et al(刘志刚, 朱健琦, 黄海珍, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2006,26(5):879. [10] DONG Yuan-xing, GAO Yu-xi, CHEN Chun-ying, et al(董元兴, 高愈希, 陈春英, 等). Chinese Journal of Analytical Chemistry(分析化学), 2006, 34(4):443. [11] CHEN Zhen-zhen,ZHANG Ning,ZHANG Wen-shen, et al(陈蓁蓁, 张 宁, 张文申, 等). Chinese Journal of Analytical Chemistry(分析化学),2006,34(9):1341. [12] YU Ying, ZHOU Zhen-tao(俞 英, 周震涛). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2005, 25(4):628. [13] Fábio A Schaberlea, Vladimir A Kuzmin, Iouri E Borissevitch. Biochimica et Biophysica Acta, 2003, 1621: 183. [14] Yu T, Ogul’chansky, Yu M, et al. Spectrochimica Acta Part A, 2001, 57:1525. [15] Wellington Pham, Lai Wen-Fu, Ralph Weissleder, et al. Bioconjugate Chem., 2003, 14: 1048. [16] Funovics M, Weissleder R, Tung C H. Anal. Bioanal. Chem.,2003,377(6):956. [17] Yarmoluk S M, Yu M Losytskyy, Yashchuk V M. Journal of Photochemistry and Photobiology B: Biology, 2002, 67: 57. [18] ZHENG Hong,CHEN Xiao-lan,HU Ming-hui,et al. Analytica Chemica Acta,2002,461:235. [19] YE Y,Bloch S,Kao J,et al. Bioconjugate Chem.,2005,16(1):51. |
[1] |
CHU Bing-quan1, 2, LI Cheng-feng1, DING Li3, GUO Zheng-yan1, WANG Shi-yu1, SUN Wei-jie1, JIN Wei-yi1, HE Yong2*. Nondestructive and Rapid Determination of Carbohydrate and Protein in T. obliquus Based on Hyperspectral Imaging Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3732-3741. |
[2] |
CHENG Hong1, YAN Ding-ce1*, WU Li-qing2, XU Jun3. Spectral Magnitude Uncertainty in Measurement of Protein Circular
Dichroism Spectra—An Empirical Study on Cytochrome C[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(10): 3105-3110. |
[3] |
ZHANG Peng1, 3, YANG Yi-fan1, WANG Hui1, TU Zong-cai1, 2, SHA Xiao-mei2, HU Yue-ming1*. A Review of Structural Characterization and Detection Methods of Glycated Proteins in Food Systems[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2667-2673. |
[4] |
CHEN Rui1, WANG Xue1, 2*, WANG Zi-wen1, QU Hao1, MA Tie-min1, CHEN Zheng-guang1, GAO Rui3. Wavelength Selection Method of Near-Infrared Spectrum Based on
Random Forest Feature Importance and Interval Partial
Least Square Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1043-1050. |
[5] |
LIAN Xiao-qin1, 2, CHEN Qun1, 2, TANG Shen-miao1, 2, WU Jing-zhu1, 2, WU Ye-lan1, 2, GAO Chao1, 2. Quantitative Analysis Method of Key Nutrients in Lanzhou Lily Based on NIR and SOM-RBF[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(07): 2025-2032. |
[6] |
LIU Mei-chen, XUE He-ru*, LIU Jiang-ping, DAI Rong-rong, HU Peng-wei, HUANG Qing, JIANG Xin-hua. Hyperspectral Analysis of Milk Protein Content Using SVM Optimized by Sparrow Search Algorithm[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(05): 1601-1606. |
[7] |
CHEN Hua-zhou1,2, XU Li-li3, QIAO Han-li1,2, HONG Shao-yong4*. Latent Variable Machine Learning Methods Applied for NIR Quantitative Analysis of Coffee[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1441-1445. |
[8] |
FAN Nai-yun, LIU Gui-shan*, ZHANG Jing-jing, ZHANG Chong, YUAN Rui-rui, BAN Jing-jing. Hyperspectral Model Optimization for Protein of Tan Mutton Based on Box-Behnken[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(03): 918-923. |
[9] |
WANG Cheng-ke, ZHANG Ze-xiang, HUANG Xiao-wei*, ZOU Xiao-bo*, LI Zhi-huang, SHI Ji-yong. Detection of Component Content Changes During Tofu Formation Based on Hyperspectral Imaging Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(11): 3549-3555. |
[10] |
ZHU Li-wei1, ZHOU Yan1, CAI Fang1, DENG Jiao1, HUANG Juan1, ZHANG Xiao-na1, ZHANG Jin-ge2, CHEN Qing-fu1*. Quantitative Analysis of Perennial Buckwheat Leaves Protein and GABA Using Near Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(08): 2421-2426. |
[11] |
LÜ Fei, ZHANG Jing, CHEN Xin-lu, LIU Jian-hua, DING Yu-ting*. Spectroscopic Method Combined with Molecular Dynamics Simulation to Study the Action Mechanism of Ozone on Myoglobin Structure[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(10): 3115-3121. |
[12] |
XU Kun1,2,3, WANG Ju-lin1,2,3*. Micro-Destructive and Rapid Chemical Identification of the Protein Binders in Colors Layers of Paintings by ATR-FTIR and Principal Component Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(07): 2299-2306. |
[13] |
JIANG Lu-lu1, WEI Xuan2, XIE Chuan-qi3*, HE Yong4*. Non-Destructive Determination of Growth Quality Indicators of Spirulina sp. Using Vis/NIR Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(08): 2493-2497. |
[14] |
CHEN Lei1, 2, LIU Mao-mao2, ZHANG Yong-jun2*, WANG Ya-xin2, HAN Xiao-xia3, ZHAO Bing3. Indirect Protein Detection by Versatile SERS Sensors[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3094-3098. |
[15] |
WANG Hao1, 2, HUANG Yan2, LIU Zhi-tong2, GAO Zhen-hua2, SUN Da-rui2, TAO Ye2*. Development of Dynamic Synchrotron Radiation Circular Dichroism Spectroscopy Using Continuous-Flow Probe with Microfluidic Mixer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2110-2114. |
|
|
|
|