光谱学与光谱分析 |
|
|
|
|
|
Deviation of Mass Peak Position in Time-of-Flight Mass Spectrum |
ZHANG Shu-dong, XU Ming-kun, KONG Xiang-he |
College of Physics and Engineering, Qufu Normal University, Qufu 273165, China |
|
|
Abstract Time-of-flight (TOF) mass spectrometer is widely used in many research areas including the study of dynamics of laser ionization/dissociation molecular clusters. A new phenomenon was observed when we used YAG 355 nm laser to ionize water/methanol mixture molecular beam and detect the ions with time-of-flight mass spectrometer: the peak positions of mass ions shift when changing the laser delay time to the molecular beam and keeping other conditions unchanged. The flight time shortens to a minimum value when the laser ionizes the middle part of the molecular beam, while the ions intensity reaches the maximum. The peak shift does not mean a new mass number ion appearing through mass spectra identification. The reason is deduced to be the voltage fluctuation on the extract electrode of TOF when ions pass through the grating electrode and part of them are being absorbed. The numerical simulation of charge-particle movement in electrical field also supports the deduction, and is consistent with the experimental results.
|
Received: 2006-01-26
Accepted: 2006-04-28
|
|
Corresponding Authors:
ZHANG Shu-dong
E-mail: zhangsd2@126.com
|
|
Cite this article: |
ZHANG Shu-dong,XU Ming-kun,KONG Xiang-he. Deviation of Mass Peak Position in Time-of-Flight Mass Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(04): 799-802.
|
|
|
|
URL: |
https://www.gpxygpfx.com/EN/Y2007/V27/I04/799 |
[1] Roy Johnston. Atomic and Molecular Clusters. London: Taylor & Francis, 2002. [2] Roger Campargue. Atomic and Molecular Beams. New York: Springer, 2001. [3] Jan Posthumus. Molecules and Clusters in Intense Laser Fields. Cambridge: Cambridge University Press,2001. [4] Burlingame A L, Steven A C. Mass Spectrometry in the Biological Sciences. Humana Press,1995. [5] XIA Bing-le, LIU Qing-liang, XU Xiao-long, et al(夏炳乐, 刘清亮, 徐小龙, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2003, 23(2): 29. [6] Kamp R M, Papadopoulou T C, Liebold B W. Protein Structure Analysis: Preparation, Characterization, and Microsequencing. New York: Springer, 1997. [7] Becker J S, Dietze H J. Int. J. Mass Spectr.,2003, 228: 127. [8] Wiley W C, Mclaren I H. Rev. Sci. Instrum.,1955, 26: 1150. [9] ZHANG Fu-yi, LIU Hong, LIN Cui(张福义, 刘 虹, 林 沝). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2000, 20(2): 237. [10] ZHANG Shu-dong, NIU Dong-mei, ZHANG Xian-yi,et al(张树东, 牛冬梅, 张先燚, 等). Acta Chimica Sinica(化学学报), 62(5): 480. [11] LI Chun-ming, DAI Song-tao, DONG Guo-xuan, et al(李春明, 戴松涛, 董国轩, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 1997, 17(1): 23.
|
[1] |
ZHU Yu-qi1, 2, ZHANG Xin2, DU Pan-pan2, LIU Shu1, ZHANG Gui-xin1, 2, GUAN Song-lei2*, ZHENG Zhong1*. Infrared Spectroscopy and X-Ray Spectroscopy Combined With
Inductively Coupled Plasma Mass Spectrometry for Quality
Control of Mongolian Medicine Yu Grain Soil[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(10): 3163-3169. |
[2] |
JIN Xu-guang1, 2, WANG Jin-zhuan1, 2*, LI Bei1, 2, QUE Wan-ting1, 2, WANG Liang1, 2, ZHANG Fan1, 2, ZHANG Chi1, ZHOU Jun-gui1, FU Rong-jin1. Quantification of Au in Gold Ornaments Obtained by Different Electroformed Process[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2755-2760. |
[3] |
ZHANG Hao-yu1, FU Biao1*, WANG Jiao1, MA Xiao-ling2, LUO Guang-qian1, YAO Hong1. Determination of Trace Rare Earth Elements in Coal Ash by Inductively Coupled Plasma Tandem Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(07): 2074-2081. |
[4] |
LIN Jing-tao, XIN Chen-xing, LI Yan*. Spectral Characteristics of “Trapiche-Like Sapphire” From ChangLe, Shandong Province[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1199-1204. |
[5] |
ZHANG Yan1, 2, WANG Hui-le1, LIU Zhong2, ZHAO Hui-fang1, YU Ying-ying1, LI Jing1, TONG Xin1. Spectral Analysis of Liquefaction Residue From Corn Stalk Polyhydric
Alcohols Liquefaction at Ambient Pressure[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 911-916. |
[6] |
YANG Guo-wu1, HOU Yan-xia1, SUN Xiao-fei2, JIA Yun-hai1*, LI Xiao-jia1. Evaluation of Long-Term Stability for Non-Standard Method and
Application in Trace Element Analysis of Pure Nickel by Glow
Discharge Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 867-876. |
[7] |
GUO Xiao-hua1, ZHAO Peng1, WU Ya-qing1, TANG Xue-ping3, GENG Di2*, WENG Lian-jin2*. Application of XRF and ICP-MS in Elements Content Determinations of Tieguanyin of Anxi and Hua’an County, Fujian Province[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(10): 3124-3129. |
[8] |
CAI Song-tao1, XIE Hua-lin2, HUANG Jian-hua3*. Analysis of Heavy Metal Cd in Cereal-Based Complementary Foods for
Infants and Young Children by Inductively Coupled Plasma Tandem
Mass Spectrometry (ICP-MS/MS)[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(09): 2818-2823. |
[9] |
ZHANG Fei1, 5,HUA Xia2*,YUAN Jia-ying3,YOU Fan1,YE Ren-cai4,DING Li4, ZHAO Jian-mei4. Determination of Thallium in Blood of Occupational Exposed Population by Inductively Coupled Plasma Mass Spectrometry With High Matrix Introduction[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(09): 2870-2874. |
[10] |
BAI Feng-yuan1, 2, ZHAO Dong-mei1, 2, CAI Ren-jun1, 2, SONG Su-fei1, 2, LIU Tao1, 2*, XU Qiu-ling1, 2*. Serum Metabolomics Study of CCI Model Rats Based on UHPLC-QE-MS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(08): 2528-2531. |
[11] |
ZHANG Yan1, WANG Hui-le1, ZHAO Hui-fang1, LI Jing1, TONG Xin1, LIU Zhong2. Optimization of Corn Stalk Liquefaction Conditions Under Atmospheric Pressure and Analysis of Biofuel[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(08): 2551-2556. |
[12] |
ZHANG Xuan1, 2, 3, WANG Chang-hua1, 2, HU Fang-fei1, 2, MO Shu-min1, 2, LI Ji-dong1, 2, 3*. Determination of Nb and Re in High Purity Tungsten by Precipitation Separation-Inductively Coupled Plasma Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(07): 2169-2174. |
[13] |
ZHU Zhao-zhou1*, YANG Xin-xin1, LI Jun1, HE Hui-jun2, ZHANG Zi-jing1, YAN Wen-rui1. Determination of Rare Earth Elements in High-Salt Water by ICP-MS
After Pre-Concentration Using a Chelating Resin[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(06): 1862-1866. |
[14] |
LU Qi-peng1, WANG Dong-min2*, SONG Yuan1*, DING Hai-quan3, GAO Hong-zhi3. Effect of Wavelength Drift on PLSR Calibration Model of Near-Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 405-409. |
[15] |
GONG Ge-lian1, 2, YOU Li-bing3, LI Cong-ying4, FANG Xiao-dong3, SUN Wei-dong4, 5, 6. Advances in Equipment for Deep Ultra-Violet Excimer Laser Ablation Coupled Plasma Mass and Optical Emission Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 555-560. |
|
|
|
|