Simulation and Experimental Measurement of Cryogenic Radiometer Cavity With Different Structures |
LIU Hong-bo, SHI Xue-shun, ZHUANG Xin-gang, ZHANG Peng-ju, LIU Chang-ming, WANG Heng-fei |
The 41st Institute of China Electronic Technology Group Corporation,Qingdao 266555, China
|
|
|
Abstract At present, the highest international benchmark for optical radiation power is cryogenic radiometer, and it can detect radiation covering the vacuum ultraviolet to terahertz spectrum (115 nm~THz). Using the optical and electric alternative principle with the vacuum, low temperature and superconducting technology, it traced the radiation power to the electrical parameters with the high precision measurement, realized super wide spectrum of optical radiation absolute power measurement, the uncertainty reached 10-5. In the field of national defence military, and optical radiation measurement, photoelectric payload, quantitative remote sensing, high spectral imaging and optical radiation quantity traceability, and others have an irreplaceable role. As the core device of radiation absorption, the cavity of the cryogenic radiometer has a flat spectral absorption with an ultra-high absorption ratio of over 0.999. The absorptance is one of the main factors affecting the high accuracy measurement of the cryogenic radiometer. The scholars at home and abroad have carried out a large number of studies with the theoretical and simulation for the different cavities. However, the experimental measurement and comparison of absorption rates of the cavity with different structural parameters have not been reported. Therefore, to realize the requirement of the wide spectrum and high precision measurement of the radiometer, the research work of developing the cavity suitable for the radiometer has been carried out. We developed four different structures. The wall was 0.1 mm thickness with high conductivity oxygen-free copper (OFHC), the inner surface electroplated nickel-phosphorus (NiP) black coating. The Monte Carlo tracing algorithm was used to simulate the absorptivity of the cavity of four structures. The absorptivity of the cavity was measured by the alternative method, and the measuring device was set up, which was composed of the high stable light source and integrating ball system. By switching the standard whiteboard and the cavity, the absorption rate of the cavity was measured, and the influencing factors of the absorption rate were analyzed. By comparing the simulation and the experimental results, the rationality of the simulation parameter setting is verified. The experimental results show that: (1) comparing the simulation and the experimental result shows, the measurement method and result are verified; (2) the cryogenic radiometer cavity has achieved 0.999 962±0.000 005@632.8 nm; (3) the absorption of the cylindrical cavity with the inclined bottom is better than that of the conical cavity; (4)By designing the screw structure to increase the cavity surface area and the conical aperture to compare with the diaphragm structure, the absorptivity is not significantly increased.
|
Received: 2021-01-05
Accepted: 2021-02-24
|
|
|
[1] Hoyt C C, Foukal P V. Metrologia, 1991, 28(3): 163.
[2] Houston J M, Cromer C L, Hardis J E, et al. Metrologia, 1993, 30(4): 285.
[3] LIU Chang-ming, SHI Xue-shun, et al(刘长明,史学舜,等). Acta Photonica Sinica(光子学报), 2016, 45(9): 0912002.
[4] Alexander V Prokhorov, Leonard M Hanssen,et al. Metrologia,2004, 41: 421.
[5] López M, Hofer H, Kück S, et al. Metrologia,2005, 42(5): 400.
[6] Fang Qianqian, Fang Wei, et al. Metrologia,2012, 49(4):572.
[7] YI Xiao-long, YANG Zhen-ling, et al(衣小龙, 杨振玲, 等). Optics and Precision Engineering(光学精密工程),2015, 23(10): 2733.
[8] Houston J M,Rice J P. Metrologia, 2006, 43: 31.
[9] Fox N P, Haycocks P R, Martin J E, et al. Metrologia, 1995, 32(6): 581.
[10] ZHUANG Xin-gang,LIU Hong-bo, ZHANG Peng-ju, et al(庄新港, 刘红博, 张鹏举,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2019, 39(7):2018.
|
[1] |
WANG Cai-ling1,ZHANG Jing1,WANG Hong-wei2*, SONG Xiao-nan1, JI Tong3. A Hyperspectral Image Classification Model Based on Band Clustering and Multi-Scale Structure Feature Fusion[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 258-265. |
[2] |
TIAN Fu-chao1, CHEN Lei2*, PEI Huan2, BAI Jie-qi1, ZENG Wen2. Study of Factors Influencing the Length of Argon Plasma Jets at
Atmospheric Pressure With Needle Ring Electrodes[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3682-3689. |
[3] |
WANG Ling-juan, OU Quan-hong, YAN Hao, TANG Jun-qi*. Preparation and Catalytic Properties of Gold Nanoflowers[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3747-3752. |
[4] |
ZHENG Ni-na1, 2*, XIE Pin-hua1, QIN Min1, DUAN Jun1. Research on the Influence of Lamp Structure of the Combined LED Broadband Light Source on Differential Optical Absorption Spectrum
Retrieval and Its Removing Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3339-3346. |
[5] |
WAN Huang-xu1, 2, LIU Ji-qiang1*, HAN Xi-qiu1, 2, LIANG Jin-long2, ZHOU Ya-dong1, FAN Wei-jia1, WANG Ye-jian1, QIU Zhong-yan1, MENG Fan-wei3. Ultrastructure and Mineral Composition of Bathymodiolus Shell From Wocan-1 Hydrothermal Vent, Northwest Indian Ocean[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3497-3503. |
[6] |
GUO Jing-fang, LIU Li-li*, CHENG Wei-wei, XU Bao-cheng, ZHANG Xiao-dan, YU Ying. Effect of Interaction Between Catechin and Glycosylated Porcine
Hemoglobin on Its Structural and Functional Properties[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3615-3621. |
[7] |
CHENG Hong1, YAN Ding-ce1*, WU Li-qing2, XU Jun3. Spectral Magnitude Uncertainty in Measurement of Protein Circular
Dichroism Spectra—An Empirical Study on Cytochrome C[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(10): 3105-3110. |
[8] |
ZHANG Peng1, 3, YANG Yi-fan1, WANG Hui1, TU Zong-cai1, 2, SHA Xiao-mei2, HU Yue-ming1*. A Review of Structural Characterization and Detection Methods of Glycated Proteins in Food Systems[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2667-2673. |
[9] |
TIAN Ze-qi1, WANG Zhi-yong1, YAO Jian-guo1, GUO Xu1, LI Hong-dou1, GUO Wen-mu1, SHI Zhi-xiang2, ZHAO Cun-liang1, LIU Bang-jun1*. Quantitative FTIR Characterization of Chemical Structures of Highly Metamorphic Coals in a Magma Contact Zone[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2747-2754. |
[10] |
LIU Guo-peng1, YOU Jing-lin1*, WANG Jian1, GONG Xiao-ye1, ZHAO Yu-fan1, ZHANG Qing-li2, WAN Song-ming2. Application of Aerodynamic Levitator Laser Heating Technique: Microstructures of MgTi2O5 Crystal and Melt by in-situ Superhigh Temperature Raman Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(08): 2507-2513. |
[11] |
TIAN Si-di1, WANG Zhen1, DU Yan-jun2, DING Yan-jun1, PENG Zhi-min1*. High Precision Measurement of Spectroscopic Parameters of CO at 2.3 μm Based on Wavelength Modulation-Direct Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(07): 2246-2251. |
[12] |
WANG Jie1, 2, 3, LIU Wen-qing1, 2, 4, ZHANG Tian-shu1, XIA Jian-dong5, DENG Wei5, HU Wen-jie5. Collaborative Observation of Vertical Structures of Ozone and Aerosol in a Dust Episode Based on Lidar[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(07): 2258-2265. |
[13] |
HU Shuang1, LIU Cui-mei2*, XU Lin3, JIA Wei2, HUA Zhen-dong2. Rapid Qualitative Analysis of Synthetic Cathinones by Raman
Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1821-1828. |
[14] |
WANG Mei-ling1, 2, 3, 4, LI Fei1, 2, 3, 4*, WANG Xu-yang1, 2, 3, 4, ZHU Han-yu1, 2, 3, 4, QIAO Meng-dan1, 2, 3, 4, YUAN Jun-sheng1, 2, 3, 4*. Study on the Structure of K2SO4 Aqueous Solutions by X-Ray Scattering and Raman Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1838-1845. |
[15] |
ZONG Zhi-fang1, 2, 3, LONG Hong-ming1*, Yilin Gui3*, ZHANG Hao1, 2, DONG Wei2, ZHOU Xiao-hui2, JI Yi-long1. Microstructure Characteristics of Nano Solid Waste High Sulfur Cement Based on XRD and FTIR[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1974-1980. |
|
|
|
|