Impact of the Spectra of LED Sources on the Light Adaptation in Tunnel Exit |
DONG Li-li, QIN Ge*, CHEN Yang, SHANG Xiong-fei, XU Wen-hai |
Information Science and Technology College, Dalian Maritime University, Dalian 116026, China |
|
|
Abstract With the development of China’s economy, the development of highway tunnel construction is also rapidly. In the early stage of engineering design to ensure the safety of traffic in the tunnel, the power and location of the tunnel lighting sources all depend on the maximum outside luminance value and vehicle speed value through out the year. Although such a design considers safety, but it blindly increases the luminance of the tunnel illumination and it can not alleviate the problem of visual adaptation. However, with the application of LED in tunnels, the impact of LED sources spectra gradually attracted people’s attention. Moreover, the investigation found that the traffic accident rate of the highway tunnel in the exit section is relatively high. The main reason is that the luminance difference between the inside and outside of the tunnel is large, and the light adaptation time is long when the driver leavesthe tunnel exit. In order to study the impact of LED sources spectra on the light adaptation in tunnel exit, and to provide a basis for the selection of light source in tunnel exit, the LED source was characterized by a wide spectrum double-peak pattern. In the long wavelength range, the spectral content is different. The light adaptation is mainly related to two factors: the change of pupil area and photochemical reaction of the photopigment. LED light sources with different color temperatures have different spectral characteristics. The spectrum affects the time of light adaptation by affecting the synthesis of photopigment. The experiment selected 7 color temperature LED light sources used in the field of highway tunnel. The color temperatures are: 3 000, 3 500, 4 000, 4 500, 5 000, 5 700 and 6 500 K. Thirty observers were chosen for the experiment. All observers had normal visual corrected visual acuity. None of the observers had night blindness, color blindness or other diseases affecting night vision functions. The experiment was carried out in a simulated tunnel with a height of 2.8 m, length of 9 m and width of 5 m. Three photopic luminance levels for the experimental LEDs (4, 8 and 12 cd·m-2), three illumination angles (15°, 20° and 25°) and two mounting heights (2.0, 2.4 m) were applied. In total, 126 lighting conditions were evaluated in the experiment. The results show that the higher luminance of the tunnel exit section, the shorter light adaptation times. When the luminance is the same, as the correlated color temperature increases, the light adaptation times decrease. The installation angle and height of the lamps have little effect on the sources spectra. Changing the installation height and angle can not effectively reduce the light adaptation time. This paper provides data and theoretical support for the selection of the color temperature in the exit section by analyzing the spectrum of LED sources with different color temperatures.
|
Received: 2019-03-08
Accepted: 2019-07-19
|
|
Corresponding Authors:
QIN Ge
E-mail: 18137297653@163.com
|
|
[1] XIAO Yao, DU Zhi-gang, TAO Peng-peng, et al(肖 尧, 杜志刚, 陶鹏鹏, 等). Journal of Wuhan University of Technology(武汉理工大学学报), 2015,(3): 573.
[2] DU Zhi-gang, HUANG Fa-ming, YAN Xin-ping, et al(杜志刚, 黄发明, 严新平, 等). Journal of Highway and Transportation Research and Development(公路交通科技), 2013, 30(5): 98.
[3] YAN Ying, YE Fei, WANG Xiao-fei, et al(阎 莹, 叶 飞, 王晓飞, 等). Journal of South China University of Technology·Natural Science Edition(华南理工大学学报), 2016, 44(12): 89.
[4] DENG Min, DAI Yan-ming(邓 敏, 代言明). Journal of Chongqing University(重庆大学学报), 2016, 39(2): 140.
[5] Rea M S, Radetsky L C, Bullough J D. Lighting Research and Technology, 2011, 43(1): 7.
[6] Bullough J D, Radetsky L C, Besenecker U C, et al. Leukos the Journal of the Illuminating Engineering Society of North America, 2014, 10(1): 3.
[7] LU Yu-hong, WANG Yu-rong, JIN Shang-zhong, et al(鲁玉红, 王毓蓉, 金尚忠, 等). Chinese Journal of Luminescence(发光学报), 2013, 34(8): 1061.
[8] Jin H, Jin S, Chen L, et al. IEEE Photo. J., 2015, 7(6): Art No. 1601309.
[9] RAO Feng, XU An-cheng, ZHU Xi-fang(饶 丰, 徐安成, 朱锡芳). Chinese Journal of Luminescence(发光学报), 2016, 37(2): 250.
[10] RAO Feng, ZHU Xi-fang, XU An-cheng, et al(饶 丰, 朱锡芳, 徐安成, 等). Acta Photonica Sinica(光子学报), 2015, 44(4): 199.
[11] Shi N, Dong L L, Qin L. Study on Lamp-Layout Scheme of Highway Tunnel Lighting Based on DIALux, International Conference on Energy and Environmental Protection, 2016.
[12] Dong Lili, Qin Li, Xu Weihai, et al. IEEE Photo. J., 2017, 9(6):Art No. 8201616. |
[1] |
ZHENG Hong-quan, DAI Jing-min*. Research Development of the Application of Photoacoustic Spectroscopy in Measurement of Trace Gas Concentration[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 1-14. |
[2] |
CHENG Jia-wei1, 2,LIU Xin-xing1, 2*,ZHANG Juan1, 2. Application of Infrared Spectroscopy in Exploration of Mineral Deposits: A Review[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 15-21. |
[3] |
FAN Ping-ping,LI Xue-ying,QIU Hui-min,HOU Guang-li,LIU Yan*. Spectral Analysis of Organic Carbon in Sediments of the Yellow Sea and Bohai Sea by Different Spectrometers[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 52-55. |
[4] |
LI Jie, ZHOU Qu*, JIA Lu-fen, CUI Xiao-sen. Comparative Study on Detection Methods of Furfural in Transformer Oil Based on IR and Raman Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 125-133. |
[5] |
BAI Xi-lin1, 2, PENG Yue1, 2, ZHANG Xue-dong1, 2, GE Jing1, 2*. Ultrafast Dynamics of CdSe/ZnS Quantum Dots and Quantum
Dot-Acceptor Molecular Complexes[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 56-61. |
[6] |
XU Tian1, 2, LI Jing1, 2, LIU Zhen-hua1, 2*. Remote Sensing Inversion of Soil Manganese in Nanchuan District, Chongqing[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 69-75. |
[7] |
WANG Fang-yuan1, 2, HAN Sen1, 2, YE Song1, 2, YIN Shan1, 2, LI Shu1, 2, WANG Xin-qiang1, 2*. A DFT Method to Study the Structure and Raman Spectra of Lignin
Monomer and Dimer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 76-81. |
[8] |
LIU Zhen1*, LIU Li2*, FAN Shuo2, ZHAO An-ran2, LIU Si-lu2. Training Sample Selection for Spectral Reconstruction Based on Improved K-Means Clustering[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 29-35. |
[9] |
YANG Chao-pu1, 2, FANG Wen-qing3*, WU Qing-feng3, LI Chun1, LI Xiao-long1. Study on Changes of Blue Light Hazard and Circadian Effect of AMOLED With Age Based on Spectral Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 36-43. |
[10] |
GAO Feng1, 2, XING Ya-ge3, 4, LUO Hua-ping1, 2, ZHANG Yuan-hua3, 4, GUO Ling3, 4*. Nondestructive Identification of Apricot Varieties Based on Visible/Near Infrared Spectroscopy and Chemometrics Methods[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 44-51. |
[11] |
ZHENG Pei-chao, YIN Yi-tong, WANG Jin-mei*, ZHOU Chun-yan, ZHANG Li, ZENG Jin-rui, LÜ Qiang. Study on the Method of Detecting Phosphate Ions in Water Based on
Ultraviolet Absorption Spectrum Combined With SPA-ELM Algorithm[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 82-87. |
[12] |
XU Qiu-yi1, 3, 4, ZHU Wen-yue3, 4, CHEN Jie2, 3, 4, LIU Qiang3, 4 *, ZHENG Jian-jie3, 4, YANG Tao2, 3, 4, YANG Teng-fei2, 3, 4. Calibration Method of Aerosol Absorption Coefficient Based on
Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 88-94. |
[13] |
LI Xin-ting, ZHANG Feng, FENG Jie*. Convolutional Neural Network Combined With Improved Spectral
Processing Method for Potato Disease Detection[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 215-224. |
[14] |
XING Hai-bo1, ZHENG Bo-wen1, LI Xin-yue1, HUANG Bo-tao2, XIANG Xiao2, HU Xiao-jun1*. Colorimetric and SERS Dual-Channel Sensing Detection of Pyrene in
Water[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 95-102. |
[15] |
LEI Hong-jun1, YANG Guang1, PAN Hong-wei1*, WANG Yi-fei1, YI Jun2, WANG Ke-ke2, WANG Guo-hao2, TONG Wen-bin1, SHI Li-li1. Influence of Hydrochemical Ions on Three-Dimensional Fluorescence
Spectrum of Dissolved Organic Matter in the Water Environment
and the Proposed Classification Pretreatment Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 134-140. |
|
|
|
|