光谱学与光谱分析 |
|
|
|
|
|
Analysis of Lorentzian Line Shape Function Broadened by Non-Sinusoidal Wavelength Modulation |
SUN You-qun, WANG Yun-tao*, RUAN Chi, XU Song-song |
State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China |
|
|
Abstract In the present work, the Fourier analysis of Lorentzian line shape broadened by non-sinusoidal wavelength modulation was investigated, in which the third order and above harmonic items were ignored. The analytical expression of n-order Fourier coefficient was brought out, where a variable K named harmonic distortion to characterize the ratio of the second harmonic to the first harmonic was introduced. Numerical simulations based on the cases of K>0.01 and K<0.01 were carried out, and the result shows: non-sinusoidal modulation has little effect compared with the sinusoidal modulation when K value is less than 0.01, however, if K value is about 0.1 or higher, the center of the Fourier amplitude curve would deviate from the origin of coordinates. With the increase in the harmonic distortion, the deviation of the curve grows, and high order harmonics are more sensitive to the non-sinusoidal modulation compared with the low order harmonics. In addition, when harmonic distortion cannot be ignored, for example K>0.01, the effect of different depths of modulation on the odd and even order harmonic amplitude curve is significant. And the numerical simulation shows there exists an optimum value of modulation depth which could minimize the impact of the harmonic distortion, and both large K value and small K value would cause a great error. The conclusion of this work could be applied in error analysis of wavelength modulation spectroscopy system. And the results are helpful to deepening understanding of WMS and would be the important reference for some kind of frequency stabilization technology in laser instrument.
|
Received: 2013-05-19
Accepted: 2013-08-24
|
|
Corresponding Authors:
WANG Yun-tao
E-mail: ytwang@opt.ac.cn
|
|
[1] Chao X, Jeffries J B, Hanson R K. Applied Physics B, 2012, 106(4): 987. [2] Gao G Z, Chen B X, Hu B. Measurement, 2013, 46(5): 1657. [3] Chao X, Jeffries J B, Hanson R K. Measurement Science and Technology, 2009, 20(11): 115201. [4] Hershberger W D. Journal of Applied Physics, 1948, 19(4): 411. [5] Arndt R. Journal of Applied Physics, 1965, 36: 2522. [6] Reid J, Labrie D. Applied Physics B, 1981, 26(3): 203. [7] Schmidt F M, Foltynowicz A, Gustafsson J, et al. Journal of Quantitative Spectroscopy and Radiative Transfer, 2005, 94(2): 225. [8] LU Jing, CAO Jia-nian, WANG Chun, et al(芦 婧, 曹家年, 王 淳, 等). Techniques of Automation and Applications(仪器仪表与检测技术), 2009, 28(3): 84. [9] Lins B, Zinn P, Engelbrecht R, et al. Applied Physics B, 2010, 100(2): 367. [10] Westberg J, Kluczynski P, Lundqvist S, et al. Journal of Quantitative Spectroscopy and Radiative Transfer, 2011, 112(9): 1443. [11] SUN Yan-guang, DONG Zuo-ren, CHEN Di-jun, et al(孙延光, 董作人, 陈迪俊, 等). Chinese Journal of Lasers(中国激光), 2013, 40(4): 0408002.
|
[1] |
LIANG Wen-ke, WEI Guang-fen, WANG Ming-hao. Research on Methane Detection Error Caused by Lorentzian Profile Approximation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1683-1689. |
[2] |
ZHANG Le-wen1, 2, WANG Qian-jin1, 3, SUN Peng-shuai1, PANG Tao1, WU Bian1, XIA Hua1, ZHANG Zhi-rong1, 3, 4, 5*. Analysis of Interference Factors and Study of Temperature Correction Method in Gas Detection by Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 767-773. |
[3] |
LIU Jiang-qing1, YU Chang-hui2, 3, GUO Yuan2, 3, LEI Sheng-bin1*, ZHANG Zhen2, 3*. Interaction Between Dipalmityl Phosphatidylcholine and Vitamin B2
Studied by Second Harmonic Spectroscopy and Brewster Angle
Microscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(05): 1484-1489. |
[4] |
WAN Liu-jie1, 2, ZHEN Chao3, QIU Zong-jia1, LI Kang1, MA Feng-xiang3, HAN Dong1, 2, ZHANG Guo-qiang1, 2*. Research of High Precision Photoacoustic Second Harmonic Detection Technology Based on FFT Filter[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 2996-3001. |
[5] |
XIE Ying-chao1,2, WANG Rui-feng1,2, CAO Yuan1,2, LIU Kun1*, GAO Xiao-ming1,2. Research on Detecting CO2 With Off-Beam Quartz-Enhanced Photoacoustic Spectroscopy at 2.004 μm[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(09): 2664-2669. |
[6] |
LI Jin-yi1, FAN Hong-qing1, TIAN Xin-li1, LI Hong-lian2, WU Zhi-chao1, SONG Li-mei1. Pressure Correction for Calibration-Free Measurement of Wavelength Modulation Spectroscopy in Atmospheric Environment[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(05): 1407-1412. |
[7] |
MEI Jiao-xu, WANG Lei*, TAN Tu, LIU Kun, WANG Gui-shi, GAO Xiao-ming. A New Method of DFB Laser Frequency Stabilization Based on the Characteristics of the Second Harmonic[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(10): 2989-2992. |
[8] |
SHAO Xin, TANG Hai-mei, WANG Feng, LI Yun-long, TAN Pan-long. Research on Closed Indoor Oxygen Concentration of Quasi-Continuous Laser Modulation Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(12): 3713-3717. |
[9] |
ZHU Gao-feng1, 2, HU Xin1, ZHU Hong-qiu1*, HU En-ze1, ZHU Jian-ping3. The Multi-Beam Interference Suppression for Measuring Penicillin Vial’s Oxygen Concentration Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(02): 372-376. |
[10] |
ZHU Gao-feng1,2, YANG Chun-hua1, ZHU Hong-qiu1*, GUI Wei-hua1. Oxygen Concentration Detection and Calibration Method Improvement in Pharmaceutical Vial Based on Wavelength Modulation Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3133-3137. |
[11] |
CUI Hai-bin1, YANG Ke1, 2, ZHANG Long1, WU Xiao-song1, LIU Yong1, WANG An1, LI Hui3, JI Min1* . Tunable Diode Laser Absorption Spectroscopy (TDLAS) Detection Signal Denoising Based on Gabor Transform [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(09): 2997-3002. |
[12] |
WANG Xiao-yu1, LI Lin1*, LIN Lu2, ZHANG Zhen2, LU Zhou2, LIU Ming-hua2, GUO Yuan2* . Chiral Transformation of PARC18 Assemblies on NaOH Solution Subphase [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(01): 47-50. |
[13] |
LIU Yang1, WU Jia-nan4, CHEN Mei-mei1, YANG Xin-hua2*, CHEN Chen3* . The Trace Methane Sensor Based on TDLAS-WMS [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(01): 279-282. |
[14] |
ZHAO Ying1, ZHAO Xue-hong1,2*, WANG Zhe1, ZHANG Rui1,3, WANG Yan1 . A New Method for Eliminating Background Signal Drift to Improve the Detection Precision in Continuous Harmonic Detection [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(11): 3224-3229. |
[15] |
SHAO Jie1, HAN Ye-xing1, GUO Jie1, WANG Li-ming1, HAN Ying1, YING Chao-fu1, WANG Yao2 . Research on Spectrum Technology Based on SG-DBR Laser [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(07): 1774-1779. |
|
|
|
|