Analysis of Interference Factors and Study of Temperature Correction Method in Gas Detection by Laser Absorption Spectroscopy |
ZHANG Le-wen1, 2, WANG Qian-jin1, 3, SUN Peng-shuai1, PANG Tao1, WU Bian1, XIA Hua1, ZHANG Zhi-rong1, 3, 4, 5* |
1. Anhui Provincial Key Laboratory of Photonic Devices and Materials, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
2. University of Science and Technology of China, Hefei 230026, China
3. School of Environment Science and Optoelectronic Technology, University of Science and Technology of China, Hefei 230026, China
4. Key Laboratory of Environmental Optics & Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
5. Advanced Laser Technology Laboratory of Anhui Province, National University of Defense Technology, Hefei 230037, China
|
|
|
Abstract Tunable diode laser absorption spectroscopy (TDLAS) is a non-invasive spectral detection technology with high selectivity, high response and high resolution. According to the principle of molecular spectral absorption, the change in target gas temperature will affect the change of molecular absorption line strength and then affect the accuracy of gas concentration inversion. In order to improve the accuracy and authenticity of gas concentration measurements in high-temperature atmospheres, carbon monoxide (CO), a common gas in industrial processes, was selected as the target gas. Experiments were designed to detect the gas spectra in multiple temperature regions (from 14 to 1 100 ℃) based on wavelength modulation technique, compared with spectral parameters in the HITRAN database, and the results were calibrated and analyzed. At the same time, the influence of different materials of sapphire window pieces was analyzed in terms of parameters such as the linearity of the detection signal. A cooling gradient measurement was selected as the temperature control sequence for the high-temperature experiment by analysing the data from the temperature rise and fall experiments. Through the high-temperature experiment with a standard concentration of CO, it was found that the second harmonic (2f) amplitude and absorption line intensity had a consistent decreasing trend with increasing temperature, by the theoretical equation of variation law. After analysis, the corrected 2f amplitude and temperature show a non-correlation and a correction for the effect of temperature on spectral detection is achieved. The shortcomings of the correction formula and the proposed improvement method are remedied, and the accuracy of the 2f amplitude correction at variable temperatures is verified. This study provides a reference for the practical application of spectral detection technology in the measurement process of high-temperature environments, especially for the dynamic evaluation of combustion efficiency in high-precision industrial furnaces, which is of great importance.
|
Received: 2022-01-26
Accepted: 2022-05-11
|
|
Corresponding Authors:
ZHANG Zhi-rong
E-mail: zhangzr@aiofm.ac.cn
|
|
[1] LIU Wen-qing, WANG Xing-ping, MA Guo-sheng, et al(刘文清, 王兴平, 马国盛, 等). Acta Optica Sinica(光学学报), 2021, 41(1): 434.
[2] Fu Bo, Zhang Chenghong, Lü Wenhao, et al. Applied Spectroscopy Reviews, 2022, 57(2): 112.
[3] KAN Rui-feng, XIA Hui-hui, XU Zhen-yu, et al(阚瑞峰, 夏晖晖, 许振宇, 等). Chinese Journal of Lasers(中国激光), 2018, 45(9): 67.
[4] Sepman A, Ögren Y, Gullberg M, et al. Applied Physics B: Lasers and Optics, 2016, 122(29): 12.
[5] Sur R, Sun K, Jeffries J B, et al. Applied Physics B: Lasers and Optics, 2014, 116(1): 33.
[6] ZHANG Bu-qiang, XU Zhen-yu, LIU Jian-guo, et al(张步强, 许振宇, 刘建国, 等). Chinese Journal of Lasers(中国激光), 2019, 46(7): 300.
[7] Xia Jinbao, Zhu Feng, Zhang Sasa, et al. Optics and Lasers in Engineering, 2019, 117: 21.
[8] Liu Ningwu, Xu Linguang, Zhou Sheng, et al. ACS Sensors, 2020, 5(11): 3607.
[9] Bolshov M A, Kuritsyn Y A, Romanovskii Y V. Spectrochimica Acta Part B: Atomic Spectroscopy, 2015, 106: 45.
[10] Chao Xing, Jeffries J B, Hanson R K. Proceedings of the Combustion Institute, 2013, 34(2): 3583.
[11] HUANG An, XU Zhen-yu, XIA Hui-hui, et al(黄 安, 许振宇, 夏晖晖, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2021, 41(4): 1144.
[12] Sepman Alexey, Ögren Yngve, Qu Zhechao, et al. Proceedings of the Combustion Institute, 2017, 36(3): 4541.
[13] Raza Mohsin, Ma Liuhao, Yao Shunchun, et al. Fuel, 2021, 305: 121591.
[14] Nevrl Václav, Dostál Michal, Klečka Vít, et al. Fuel, 2020, 263: 116652.
[15] Peng Zhimin, Du Yanjun, Ding Yanjun. Sensors (Basel), 2020, 20(3): 681.
[16] ZHANG Zhi-rong, WU Bian, XIA Hua, et al(张志荣, 吴 边, 夏 滑, 等). Acta Physica Sinica(物理学报), 2013, 62(23): 183.
[17] Raza Mohsin, Ma Liuhao, Yao Chenyu, et al. Optics & Laser Technology, 2020, 130: 106344.
[18] Liu Ningwu, Xu Linguang, Zhou Sheng, et al. Analyst, 2021, 146: 3841.
[19] He Dong, Peng Zhimin, Ding Yanjun. Fuel, 2021, 284: 118980.
[20] Gordon I E, Rothman L S, Hill C, et al. Journal of Quantitative Spectroscopy and Radiative Transfer, 2017, 203: 3.
|
[1] |
LIANG Wen-ke, WEI Guang-fen, WANG Ming-hao. Research on Methane Detection Error Caused by Lorentzian Profile Approximation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1683-1689. |
[2] |
LOU Deng-cheng, RAO Wei*, SONG Jun-ling, WANG Kai, JIANG Ya-jing, GUO Jian-yu. Research of Carbon Monoxide Concentration Measurement in Combustion Field by Off-Axis Integrated Cavity Output Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(12): 3678-3684. |
[3] |
LIU Jiang-qing1, YU Chang-hui2, 3, GUO Yuan2, 3, LEI Sheng-bin1*, ZHANG Zhen2, 3*. Interaction Between Dipalmityl Phosphatidylcholine and Vitamin B2
Studied by Second Harmonic Spectroscopy and Brewster Angle
Microscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(05): 1484-1489. |
[4] |
WAN Liu-jie1, 2, ZHEN Chao3, QIU Zong-jia1, LI Kang1, MA Feng-xiang3, HAN Dong1, 2, ZHANG Guo-qiang1, 2*. Research of High Precision Photoacoustic Second Harmonic Detection Technology Based on FFT Filter[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 2996-3001. |
[5] |
XIE Ying-chao1,2, WANG Rui-feng1,2, CAO Yuan1,2, LIU Kun1*, GAO Xiao-ming1,2. Research on Detecting CO2 With Off-Beam Quartz-Enhanced Photoacoustic Spectroscopy at 2.004 μm[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(09): 2664-2669. |
[6] |
LI Jin-yi1, FAN Hong-qing1, TIAN Xin-li1, LI Hong-lian2, WU Zhi-chao1, SONG Li-mei1. Pressure Correction for Calibration-Free Measurement of Wavelength Modulation Spectroscopy in Atmospheric Environment[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(05): 1407-1412. |
[7] |
XIAO Hu-ying1, YANG Fan1, XIANG Liu1, HU Xue-jiao2*. Jet Vacuum Enhanced Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(10): 2993-2997. |
[8] |
MEI Jiao-xu, WANG Lei*, TAN Tu, LIU Kun, WANG Gui-shi, GAO Xiao-ming. A New Method of DFB Laser Frequency Stabilization Based on the Characteristics of the Second Harmonic[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(10): 2989-2992. |
[9] |
SHAO Xin, TANG Hai-mei, WANG Feng, LI Yun-long, TAN Pan-long. Research on Closed Indoor Oxygen Concentration of Quasi-Continuous Laser Modulation Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(12): 3713-3717. |
[10] |
LI Zheng-hui1,3, YAO Shun-chun1,3*, LU Wei-ye2, ZHU Xiao-rui1,3, ZOU Li-chang1,3, LI Yue-sheng2, LU Zhi-min1,3. Study on Temperature Correction Method of CO2 Measurement by TDLAS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(07): 2048-2053. |
[11] |
XU Xing-wei1, 2, WANG Wei1*, LIU Cheng3, SHAN Chang-gong4, SUN You-wen1, HU Qi-hou1, TIAN Yuan1, HAN Xue-bing1, YANG Wei1. Observations of Total Columns of CO Based on Solar Absorption Spectra[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(05): 1329-1334. |
[12] |
ZHU Gao-feng1, 2, HU Xin1, ZHU Hong-qiu1*, HU En-ze1, ZHU Jian-ping3. The Multi-Beam Interference Suppression for Measuring Penicillin Vial’s Oxygen Concentration Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(02): 372-376. |
[13] |
ZHU Gao-feng1,2, YANG Chun-hua1, ZHU Hong-qiu1*, GUI Wei-hua1. Oxygen Concentration Detection and Calibration Method Improvement in Pharmaceutical Vial Based on Wavelength Modulation Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3133-3137. |
[14] |
CUI Hai-bin1, YANG Ke1, 2, ZHANG Long1, WU Xiao-song1, LIU Yong1, WANG An1, LI Hui3, JI Min1* . Tunable Diode Laser Absorption Spectroscopy (TDLAS) Detection Signal Denoising Based on Gabor Transform [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(09): 2997-3002. |
[15] |
LI Chun-guang1, DANG Jing-min1, CHEN Chen2*, WANG Yi-ding1*. Multi-Pass Absorption Spectroscopy for CO Detection Using a Quantum Cascaded Laser[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1308-1312. |
|
|
|
|