光谱学与光谱分析 |
|
|
|
|
|
In-Situ Instrument for Rapid Detection of Nitrates and Nitrites in Water |
LI Cai1, GUI Jing-chuan1, 2, SUN Ling-yan1, 2, CAO Wen-xi1, SUN Zhao-hua1, YANG Yue-zhong1 |
1. State Key Laboratory of Tropical Oceanography South China Sea Institute of Oceanology, Chinese Academy of Sciences, Guangzhou 510301, China 2. University of Chinese Academy of Sciences, Beijing 100049, China |
|
|
Abstract A new in-situ instrument to simultaneously and rapidly detect the nitrates and nitrites of water is presented based on the sequential injection analysis (SIA) and spectrophotometer. The optimal time and injection speed for incomplete chemical color reaction of nitrite with reagent and deoxidization efficiency of cadmium column on changing nitrate to nitrite were studied and selected to obtain the rapid detection speed (the detection time for a sample can be as short as 5 mins for nitrates and 4 min for nitrites) of nitrates and nitrites in situ. In this instrument, the liquid-core waveguide (LCW) was adopted to replace the quartz cuvette as the colorimetric cell to obtain a relatively low detection limit(nmol·L-1) and very small sample consumption, and all water sample was filtered before sample injection and measurement. These measures make this in-situ detection instrument have the advantages of complete automation, very quick detection speed, low weight and power consumption, and good versatility and extensibility. Only by replacing the reagent or LCW, it also can be used to measure the trace element of water or other nutrition elements such as phosphate, silicate etc, in different sea areas in profile or fixed-point.
|
Received: 2012-11-02
Accepted: 2013-02-26
|
|
Corresponding Authors:
LI Cai
E-mail: liclaire@scsio.ac.cn
|
|
[1] Jonathan P Zehr, Raphael M Kudela, Annu. Rev. Mar. Sci. 2011. 3: 197. [2] Liu Chao, Kang Jiancheng, Wang Guodong, et al. Energy Procedia, 2012, 16: 1193. [3] Frank A. Whitney, J. Oceanogr., 2011, 67: 481. [4] Curtis Deutsch, Thomas Weber, Annu. Rev. Mar. Sci., 2011, 4: 113. [5] Thomas S. Weber Curtis Deutsch. Nature, 2011, 467: 550. [6] Anne Daniel, Roger Kérouel, Alain Aminot. Marine Chemistry, 2012, 128(12): 57. [7] Suhaimi Suratman, Keith Weston, Naomi Greenwood, et al. Coastal and Shelf Science, 2010, 87(4): 631. [8] Vuillemin R, Le Roux D, Dorval P, et al K. Deep-Sea Research, 2009, 56: 1391. [9] Katerina Mervartová, Miroslav Poláasek, José Martínez Calatayud. Journal of Pharmaceutical and Biomedical Analysis, 2007, 45(3): 367. [10] Fernando Maya, José Manuel Estela, Víctor Cerdà. Anal. Bioanal. Chem., 2009, 394:1577. [11] LI Cai, SUN Zhao-hua, CAO Wen-xi, et al(李 彩, 孙兆华, 曹文熙, 等). Optical Technique, 2009, 35(4): 579. |
[1] |
LI Wen, CHEN Yin-yin*, LUO Xue-ke, HE Na. Research on Testing NH3-N and COD in Water Quality Based on
Continuous Spectroscopy Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(01): 254-259. |
[2] |
DU Bao-lu, LI Meng, GUO Jin-jia*, ZHANG Zhi-hao, YE Wang-quan, ZHENG Rong-er. The Experimental Research on In-Situ Detection for Dissolved CO2 in
Seawater Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1264-1269. |
[3] |
LI Wen, CHENG Li*, WANG Li-min, XU Ming-gang, ZHANG Peng. Study on New Method of Online Detection of Total Alkalinity of Trace In-Situ Water Quality[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1477-1482. |
[4] |
LI Wen, WANG Li-min*, CHENG Li, CHEN Hai-qi. Sequential Injection-Continuous Spectroscopy Based Multi-Parameter Method for Water Quality Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(02): 612-617. |
[5] |
YANG Ze-ming1, 2, LI Cai1*, LU Gui-xin1, CAO Wen-xi1. A Study of Fast Detection of Nitrite in Seawater Based on Sequential Injection Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(02): 589-595. |
[6] |
WU Xin1,2, LI Guang-lin1*, WEN Zhi-yu3. Study and Determination the Concentration of CNO-Ion of the QPQ with the Sequential Injection Spectrophotometric Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(06): 1824-1828. |
[7] |
ZHANG Fang-kun, LIU Tao*, GUAN Run-duo. In-situ ATR-FTIR Measurement of Solution Concentration Based on Temperature-Related Spectra Difference Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3011-3015. |
[8] |
WANG Bin1,4, ZHENG Cheng-bin2, WANG Jun-wei3, FENG Li1, LI Shao-bo1, DAN De-zhong1, LENG Geng1* . Determination of Trace Amounts of Mercury in Sediments by Sequential Injection Cold Vapor Atomic Fluorescence Spectrometry Coupled with Microwave-Assisted Digestion[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(04): 1106-1110. |
[9] |
DUAN Ti-yu1,2,SUN Qiang1,ZHENG Hai-fei1* . Applications of Moissanite Anvil Cell for Raman Spectroscopy under High-Temperature and High-Pressure [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(06): 902-905. |
[10] |
CHEN Xu-wei, FAN Shi-hua*, WANG Shi-li. Determination of Sulfur Dioxide in Air by Sequential Injection Spectrophotometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(05): 761-764. |
[11] |
WANG Ai-jun, FAN Jing*, FENG Su-ling,CUI Feng-ling . Spectral Study and Determination of Metoclopramide and Procaine Hydrochloride by Sequential Injection Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(03): 432-435. |
[12] |
WANG Yang, FAN Shi-hua*. Determination of Nitrite in Water Samples by Sequential Injection Analysis with Chemiluminescence Detection on Chip Flow Cell [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(02): 184-187. |
[13] |
WANG Chen-yi1,2, ZHANG Cai-hua1, BI Shu-ping1*, ZHANG Zhen-chao3, YANG Wei-hua3 . Assay of Three Kinds of Aluminum Fractions (Ala, Alb and Alc) in Polynuclear Aluminum Solutions by Al-Ferron Timed Spectrophotometry and Demarcation of Their Time Limits[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(02): 252-256. |
[14] |
FAN Shi-hua, WANG Shi-li, FAN Xiao-feng, WANG Fu-ren, FANG Zhao-lun . Studies on Sequential Injection Spectrophotometric System Using A Reflective Flow Cell for Process Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24(03): 368-371. |
|
|
|
|