Application and Progress of Residual Magnetometry Based on Electron Paramagnetic Resonance Spectroscopy |
ZHANG Quan-zhe1, ZOU Sheng1, ZHANG Hong1, 2* |
1. School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
2. Beijing Academy of Quantum Information Sciences, Beijing 100193, China
|
|
|
Abstract Electron paramagnetic resonance, which is similar to nuclear magnetic resonance, is a method based on the paramagnetism and Zeeman splitting of electron magnetic moments in an external magnetic field. It is associated with unpaired electrons inside matter and external magnetic fields. Extremely weak magnetic fields are generally defined as those on the order of nT or less. Currently, scientific research is often conducted in extremely weak magnetic environments, such as basic physics research, biomagnetism of the heart and brain, etc. Therefore, stable and reliable magnetic shielding is often used to create the required environment. Magnetic shielding includes passive magnetic shielding and active magnetic compensation. Passive magnetic shielding refers to using a magnetic shielding chamber to shield the external magnetic field, which often has a certain amount of residual magnetic field inside. To facilitate further active magnetic compensation, it is necessary to detect the residual magnetic field inside shielding. At present, the means of measuring the residual magnetic field in the shielding room are mainly divided into commercial magnetometer measurement and in-situ measurement. The commercial magnetometer measurement method is simple, with low accuracy and high noise, and it is not conducive to miniaturization. With low noise, in-situ measurements are the main method of study now. Since the outermost layer of the alkali metal atom contains an unpaired electron, it becomes an ideal sample for electron paramagnetic resonance experiments. With the development of laser and optical pumping, it has been realized to probe the electron paramagnetic resonance spectrum of alkali metal atoms by Faraday rotation. The in-situ measurement of residual magnetic fields by related electron paramagnetic resonance spectrum of alkali metal vapor is profitable and precise and has great promise for application. Usually, the electron paramagnetic resonance-based residual magnetometry system includes the residual magnetic environment and sample module, the optical probe module, the signal modulation module, the environmental monitoring module, and the data acquisition and procession module, with the core being the optical probe module, which determines the sensitivity of the magnetic field measurement. This paper briefly describes the principle of the electron paramagnetic resonance technique, introduces typical magnetometers based on this technique and current developments with a focus on optically-pumped magnetometers, and outlines the residual magnetometry system based on electron paramagnetic resonance spectroscopy, each component module and the current development of related technologies in recent years.
|
Received: 2022-06-24
Accepted: 2022-10-31
|
|
Corresponding Authors:
ZHANG Hong
E-mail: zhanghong@baqis.ac.cn
|
|
[1] LI Da-ming, HUANG Ming-zhe (李大明, 黄明哲) . Physics(物理), 1992,(5): 293.
[2] Breschi E, Knowles P, Weis A, et al. Applied Physics Letters, 2014, 104(2): 023501.
[3] Schultze V, Schillig B, Ijsselsteijn R, et al. Sensors, 2017, 17(3): 561.
[4] Oelsner G, Ijsselsteijn R, Scholtes T, et al. Physical Review Applied, 2022, 17(2): 024034.
[5] Bison G, Wynands R, Weis A. Applied Physics B, 2003, 76(3): 325.
[6] Groeger S, Bison G, Schenker J L, et al. The European Physical Journal D-Atomic, Molecular, Optical and Plasma Physics, 2006, 38(2): 239.
[7] Vershovskii A K. Technical Physics Letters, 2011, 37(2): 140.
[8] Ranjbaran M, Tehranchi M M, Hamidi S M, et al. Journal of Magnetism and Magnetic Materials, 2017, 441: 718.
[9] Soheilian A, Ranjbaran M, Tehranchi M M. Scientific Reports, 2020, 10(1): 1294.
[10] Vershovskiǐ A K, Pazgalev A S. Technical Physics, 2006, 51(7): 924.
[11] Grujic Z D, Koss P A, Bison G, et al. The European Physical Journal D, 2015, 69(5): 135.
[12] Vershovskii A K, Dmitriev S P, Pazgalev A S. Technical Physics, 2013, 58(10): 1481.
[13] Alem O, Sander T H, Mhaskar R, et al. Physics in Medicine & Biology, 2015, 60(12): 4797.
[14] Zhang H, Zou S, Chen X. IEEE Transactions on Magnetics, 2016, 52(10): 4002906.
[15] Zhang H, Zou S, Chen X Y. The European Physical Journal D, 2016, 70(10): 203.
[16] Zhang H, Zou S, Chen X, et al. Optics Express, 2016, 24(15): 17234.
[17] Zhang H, Zou S, Quan W, et al. IEEE Transactions on Instrumentation and Measurement, 2019, 69(6): 3191.
[18] Zou S, Zhang H, Chen X, et al. Measurement, 2022, 187: 110338.
[19] Li J, Quan W, Zhou B, et al. IEEE Sensors Journal, 2018, 18(20): 8198.
[20] Lubkin G B. Physics Today, 1970, 23(6): 56.
[21] Kelha V, Pukki J, Peltonen R, et al. IEEE Transactions on Magnetics, 1982, 18(1): 260.
[22] Sasada I, Nakashima Y. Journal of Applied Physics, 2008, 103(7): 07E932.
[23] Masuzawa M, Tsuchiya K, Terashima A. IEEE Transactions on Applied Superconductivity, 2014, 24(3): 3500104.
[24] Gu C, Chen S, Pang T, et al. Applied Physics Letters, 2017, 110(19): 193505.
[25] Scholtes T, Schultze V, Ijsselsteijn R, et al. Physical Review A, 2011, 84(4): 043416.
[26] Alexandrov E B. Physica Scripta, 2003, 2003(T105): 27.
[27] Gan Q, Shang J, Ji Y, et al. Review of Scientific Instruments, 2017, 88(11): 115009.
[28] Ito Y, Ohnishi H, Kamada K, et al. AIP Advances, 2012, 2(3): 032127.
[29] Korth H, Strohbehn K, Tejada F, et al. Journal of Geophysical Research: Space Physics, 2016, 121(8): 7870.
[30] Groeger S, Pazgalev A S, Weis A. Applied Physics B, 2005, 80(6): 645.
[31] Jia Y, Liu Z, Chai Z, et al. IEEE Transactions on Instrumentation and Measurement, 2021, 70: 7005409.
[32] Pradhan S, Behera R. Sensors and Actuators A: Physical, 2019, 290: 48.
[33] Nardelli N V, Perry A R, Krzyzewski S P, et al. EPJ Quantum Technology, 2020, 7(1): 11.
[34] Hu Y, Hu Z, Liu X, et al. Applied Optics, 2017, 56(21): 5927.
[35] Bell W E, Bloom A L, Lynch J. Review of Scientific Instruments, 1961, 32(6): 688.
[36] Schwindt P D D, Knappe S, Shah V, et al. Applied Physics Letters, 2004, 85(26): 6409.
[37] Nieradko L, Gorecki C, Douahi A, et al. Journal of Micro/Nanolithography, MEMS, and MOEMS, 2008, 7(3): 033013.
[38] Ban K, Hirai Y, Tsujimoto K, et al. Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films, 2016, 34(6): 061601.
[39] Li Z, Wakai R T, Walker T G. Applied Physics Letters, 2006, 89(13): 134105.
[40] Wang J, Fan W, Yin K, et al. Physical Review A, 2020, 101(5): 053427.
[41] Johnson C, Schwindt P D D. 2010 IEEE International Frequency Control Symposium. IEEE, 2010: 371.
[42] Kornack T W, Smullin S J, Lee S K, et al. Applied Physics Letters, 2007, 90(22): 223501.
[43] Shah V, Romalis M V. Physical Review A, 2009, 80(1): 013416.
[44] Preusser J, Knappe S, Kitching J, et al. 2009 IEEE International Frequency Control Symposium Joint with the 22nd European Frequency and Time forum. IEEE, 2009: 1180.
[45] Ledbetter M P, Savukov I M, Acosta V M, et al. Physical Review A, 2008, 77(3): 033408.
[46] Fu M, Huang J, Ruan J, et al. 2020 35th Youth Academic Annual Conference of Chinese Association of Automation (YAC). IEEE, 2020: 28.
[47] XU Guo-wei, ZHANG Yan, JIANG Qi-yuan, et al(许国伟, 张 燚, 江奇渊, 等). Infrared and Laser Engineering(红外与激光工程), 2019, 48(S1): 21.
[48] WANG Yan-zhang, QIN Jia-nan, ZHANG Xue, et al(王言章, 秦佳男, 张 雪, 等). Journal of Jilin University(Engineering and Technology Edition)[吉林大学学报(工学版)], 2017, 47(2): 686.
[49] Xin H, Huang T, Liu X, et al. 2009 Third International Conference on Genetic and Evolutionary Computing. IEEE, 2009: 537.
[50] Jonsson B E. 2010 17th IEEE International Conference on Electronics, Circuits and Systems. IEEE, 2010: 766.
[51] Murmann B. 2008 IEEE Custom Integrated Circuits Conference. IEEE, 2008: 105.
[52] CHAI Bao-yu, LIN Xiao-peng, GUO Dong-hui(柴宝玉, 林晓鹏, 郭东辉). Journal of Xi'an Shiyou University(Natural Science Edition)[西安石油大学学报(自然科学版)], 2006,(3): 94.
[53] SUN Tong, LI Dong-mei(孙 彤, 李冬梅). Microelectronics(微电子学), 2007,(4): 523.
[54] Vardhini P A, Makkena M L. International Journal of Speech Technology, 2021, 24(2): 401.
[55] Aziz P M, Sorensen H V, vn der Spiegel J. IEEE signal processing magazine, 1996, 13(1): 61.
[56] YANG Hai-gang, SUN Jia-bin, WANG Wei(杨海钢, 孙嘉斌, 王 慰). Journal of Electronics & Information Technology(电子与信息学报), 2010, 32(3): 714.
[57] Yu S, Chen W, Li L, et al. 2006 IEEE Conference on Robotics, Automation and Mechatronics. IEEE, 2006: 778.
[58] Jung S, Kim S S. IEEE Transactions on Industrial Electronics, 2007, 54(1): 265. |
[1] |
SUN Kai-yue1, 2, CHEN Xiao-ming2, HAN Wen2*, HE Ming-yue1*, LU Tai-jin2. Study on Color Formation and Identification Characteristics of Blood Amber Produced by Irradiation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1459-1464. |
[2] |
YAN Xiao-xu1, YUE Su-wei1, 2*, SU Lü-man1, WANG Zhi-wen1. Gemological and Spectroscopic Characteristics of Natural White Sodalite With Tenebrescence[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(12): 3936-3941. |
[3] |
LI Chao-ying, HUANG Xian-kai, TU Qiu, WANG Wei-yang, ZHENG Xue-mei . Theoretical Investigation of the Electron Paramagnetic Resonance Parameters and Local Structures for Zinc Phosphate Glass Doped with VO2+[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(07): 1808-1811. |
[4] |
WU Xiao-xuan1,4,FENG Wen-lin2,3,ZHENG Wen-chen3,4. Studies of the g Factor and Optical Spectra for CaZrO3∶Mn4+ Crystal[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28(08): 1705-1707. |
[5] |
FENG Wen-lin1,3, WU Xiao-xuan2,3,4, ZHENG Wen-chen3,4. Investigation of Optical and EPR Spectra of ZnO∶V3+ Crystal[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(09): 1689-1691. |
[6] |
WU Xiao-xuan1, 2, 3,ZHENG Wen-chen2, 3,LIU Hong-gang2. Study on the Optical and EPR Spectra of CuAlS2∶Ni+[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(03): 417-419. |
[7] |
WU Xiao-xuan1, 2, 3,ZHENG Wen-chen2, 3 . Study on the Contribution of the Charge Transfer Excited States in Ba2MgGe2O7∶Cr4+ Crystal to g Factor [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(01): 8-11. |
[8] |
XU Chang-tan. Investigation of Electron Paramagnetic Resonance Spectrum in Ni2+:RbMgF3[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24(12): 1594-1596. |
[9] |
MENG Yu-fei1,PENG Ming-sheng1,CHEN Wen-xuan2. Spectroscopic Studies on Transition Metal Ions in Colored Diamonds[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24(07): 769-774. |
|
|
|
|