Research on Water Spectral Differences Based on Field Object
Spectrometer and Water Spectrometer |
CAO Xiao-yi1, CUI Jian-yong1*, DONG Wen2, XU Ming-ming1, WAN Jian-hua1 |
1. College of Oceanography and Space Informatics, China University of Petroleum (East China), Oingdao 266580, China
2. Academy of Aerospace Information Innovation, Chinese Academy of Sciences, Beijing 100094, China
|
|
|
Abstract In-site measured water spectral data is the basis of remote sensing inversion. Field object spectrometers are usually used to measure water spectral data. However, the usability of field object spectrometers for water measurements is difficult to evaluate. This article uses the data from the water measurement experiments of the field object spectrometer and the water spectrometer to conduct a difference analysis in terms of noise immunity, measurement results, external environment affecting the two types of instruments, and water quality parameter inversion. Before comparing the differences between the two types of spectrometers for water spectrum measurement, a comparison of the anti-noise capabilities of the two instruments found that the water spectrometer has a stronger anti-noise ability, so the data of the water spectrometer is used as a reference standard for analysis. First of all, regarding the difference in solar irradiance, the correlation coefficient of the solar irradiance measured by the two types of instruments varies in the range of 0.5~0.75, and there is a correlation between the solar irradiance of the two instruments; Secondly, by comparing the changes in skylight radiance at the five wavelengths of 361, 411, 461, 511, and 561 nm, we found that the range of changes in solar radiance obtained by the water spectrometer is smaller. The data acquisition is more stable than the field object spectrometer. By comparing the changes in the total radiance of the sea surface at different times, it is found that there are differences in the radiance obtained by the water spectrometer at different times, and the two change curves are different. The signal-to-noise ratio of the field object spectrometer decreases when the sunlight is weak, resulting in drastic fluctuations in the observed values of each band. The calculated reflectivity difference is obvious before 10 am and after 4 pm. Finally, the comparison shows that the external environment under different wind speed conditions impacts the air-water interface reflectance during the processing of the two instruments. The data needs to be corrected according to the value of the air-water interface reflectance corresponding to the wind speed so that the remote sensing reflectance obtained can be more precise. After the spectrometer obtains the water reflection spectrum curve, it is usually used for quantitative inversion of water quality parameters. To compare and analyze the impact of the observation results of the two spectrometers on the inversion accuracy of water quality parameters, this paper uses the water reflection spectrum curves observed by the two instruments to estimate the suspended matter concentration. The inversion is compared with the experimental test results of water samples collected at the corresponding locations. It is found that the two results are quite different. The accuracy of the water spectrometer is higher than that of the field object spectrometer. In addition, the two instruments could not be mixed, making the result error even greater. Through the processing and analysis of data obtained by two spectrometers and the inversion of water quality parameters, this article provides suggestions for water measurement using field object spectrometers to obtain more accurate and reliable water spectrum curves.
|
Received: 2023-12-12
Accepted: 2024-06-21
|
|
Corresponding Authors:
CUI Jian-yong
E-mail: cui_jianyong@upc.edu.cn
|
|
[1] WU Tai-xia, YAN Lei, XIANG Yun, et al(吴太夏, 晏 磊, 相 云, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2010,30(2): 448.
[2] LI Tong-ji, CHEN Qing-lian, ZHU Jian-hua(李铜基, 陈清莲, 朱建华). Marine Science Bulletin(海洋通报), 2002, 21(6): 9.
[3] Mobley C D. Applied Optics, 1999, 38(36): 7442.
[4] Toole D A, Siegel D A, Menzies D W, et al. Applied Optics, 2000, 39(3): 456.
[5] Doxaran D,Froidefond J M,Castaing P. International Journal of Remote Sensing, 2002, 23(23):5079.
[6] YANG Meng-yi, JIANG Xue-zhong, HE Qing(杨孟毅, 蒋雪中, 何 青). Infrared(红外), 2017, 38(12): 6.
[7] YANG Meng-yi, ZENG Jian, ZHANG Bo-hu, et al(杨孟毅, 曾 剑, 张伯虎, 等). Remote Sensing Information(遥感信息), 2018, 33(5): 21.
[8] Mueller J L, Fargion G S. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3, Volume 1. NASA/TM-2002-210004/Rev 3-Vol 1. 2002.
[9] LIANG Wen-dong, ZHOU Yao-qi, SUN Qi, et al(梁文栋, 周瑶琪, 孙 棋, 等). Marine Geology Frontiers(海洋地质前沿), 2015, 31(12): 27.
[10] TANG Jun-wu, TIAN Guo-liang, WANG Xiao-yong, et al(唐军武, 田国良, 汪小勇, 等). National Remote Sensing Bulletin(遥感学报), 2004,8(1): 37.
[11] LIU Si-feng, CAI Hua, YANG Ying-jie, et al(刘思峰, 蔡 华, 杨英杰, 等). Systems Engineering-Theory & Practice(系统工程理论与实践), 2013, 33(8): 2041.
[12] YAN Guang-jian, JIANG Hai-lan, YAN Kai, et al(阎广建, 姜海兰, 闫 凯, 等). National Remote Sensing Bulletin(遥感学报), 2021, 25(1): 83.
[13] Gordon H R, Brown O B, Evans R H, et al. Journal of Geophysical Research,1988,93(D9):10909.
[14] Ruddick K G, De Cauwer V, Park Y J, et al. Limnology and Oceanography, 2006, 51(2):1167.
[15] PAN Ying-yang, GUO Qiao-zhen, FU Ying(潘应阳, 国巧真, 付 盈). Environmental Monitoring in China(中国环境监测), 2018, 34(3): 148.
[16] HAN Xiu-zhen, WU Zhao-yang, ZHENG Wei, et al(韩秀珍, 吴朝阳, 郑 伟,等). Journal of Applied Meteorological Science(应用气象学报), 2010, 21(6): 724.
[17] Hou Y K, Zhang A B, Lv R L, et al. Environmental Science and Pollution Research International, 2022, 29(42): 63640.
|
[1] |
LIN Fang1, 2, LIU Wen-qing1, 2*, WANG Yu3, CHANG Zhen2, ZHANG Quan2, SI Fu-qi2. Dark Current Analysis and Processing Method of Environment
Monitoring Instrument Nadir and Limb[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2025, 45(03): 789-797. |
[2] |
WANG Jia-qi1, 2, JI Tuo4, CHANG Liang1, 2, 3*. Accuracy Analysis of Simultaneous Wavelength Calibration for
LiJET Spectrograph[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2025, 45(02): 456-462. |
[3] |
LI Hao-ran1, 2, ZENG Yi1*, ZHU Lei1, DOU Ke1, LIU Zhi-hong1, 3, CHANG Zhen1, JIANG Yu1, SI Fu-qi1. Measurement of Photolysis Rate of Trace Gases Based on Self-Developed Spectrometers[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2025, 45(01): 15-23. |
[4] |
WANG Shuo1, 2, XIE Zhen-kun1, 2, WEI Zhi-peng1*. DMD-Based Hadamard Transform Near-Infrared Spectrometer Design and Implementation of Fast Processing System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2025, 45(01): 133-138. |
[5] |
WANG Xin-qiang1, 3, WANG Zhen1, 3, QIN Shan1, 3, XIONG Wei2, 4, WANG Fang-yuan1, 3, YE Song1, 3, NIE Kun1, 3*. Research on the Correction of Spatial Heterodyne Interference Data Based on Principal Component Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(12): 3333-3338. |
[6] |
GAI Qiao-na, LOU Xiao-ping, LÜ Sheng-yu-jie, MU Tao-tao*. Improved Segmental Polynomial Fitting Algorithm for Two-Dimensional Spectral Restoration[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(09): 2594-2599. |
[7] |
SHEN Yong-cai1, NIU Yu-fan1, KONG De-feng2, YE Yang2*, ZHANG Shou-biao3, LI Da-chuang1, TAN Ming-sheng2, HUANG Yan-qing4, ZHAO Zhi-hao5, ZI Peng-fei3, ZHANG Xiao-hui5, WEN Fei3. Development and Performance Test of a Seya-Namioka Vacuum
Ultraviolet Spectroscopy System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(08): 2158-2165. |
[8] |
WANG Cong1, 2, Mara Camaiti3, LIU Dai-yun4, TIE Fu-de2, 5, CAO Yi-jian5, 6*. Recent Advances in the Application of the Field-Portable Hyperspectral Radiometer to Characterize Materials Concerning Cultural Heritage[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(05): 1218-1226. |
[9] |
WU Jing-yi1, ZHOU Zhe-hai1*, ZHAO Shuang1, MIN Kun-long2, LI Hui-yu1. High-Resolution Near-Infrared Micro-Spectrometer With Dual Gratings and a Cylindrical Lens[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(04): 1144-1150. |
[10] |
LI Wen-kai1, 2, ZHOU Liang1*, LIU Zhao-hui1, CUI Kai1, LIU Kai1, LI Zhi-guo1,XIE Mei-lin1. Temperature Measurement Method for Small Target Medium-Wave
Infrared Spectral Radiation Based on Distance Correction[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(04): 1158-1164. |
[11] |
WANG Mao-cheng1, LI Gan1, CHENG Hao2, JIANG Wei1, CHEN Guang1, LI Hai-bo1*. Double-Wavelength NIR Raman Spectroscopy and the Application on
Corrosion Products[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(03): 756-761. |
[12] |
LIU Bi-wang1, LU Rong-rong2, CAO Yue2, WANG Xiu-wen3, ZHAO Huan4, HAO Miao3, MA Xiao-xia3, MA Yan-miao2, WANG Yong-hui2. FTIR Study on the Effect of DangGuiTongFengFang on Hyperuricemia Nephropathy in Mice[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(03): 800-806. |
[13] |
ZHANG Xiao-li1, WANG Yu1, 2*, XI Liang2, ZHOU Hai-jin2, CHANG Zhen2, SI Fu-qi2. Application Research of Airborne Optical Fiber Imaging Differential
Absorption Spectrometer in Measuring Regional Air Pollution[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(02): 310-317. |
[14] |
LI Xin-quan1, 2,ZHANG Jun-qiang1, 3*,WU Cong-jun1,MA Jian1, 2,LU Tian-jiao1, 2,YANG Bin3. Optical Design of Airborne Large Field of View Wide Band Polarization Spectral Imaging System Based on PSIM[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 250-257. |
[15] |
FAN Ping-ping,LI Xue-ying,QIU Hui-min,HOU Guang-li,LIU Yan*. Spectral Analysis of Organic Carbon in Sediments of the Yellow Sea and Bohai Sea by Different Spectrometers[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 52-55. |
|
|
|
|