On-Line Measurement of Converter Combustion Flame with Radiation Thermometry and AES |
WANG Yong-qing, CHEN Yan-ru, ZHAO Qi*, ZHOU Mu-chun, SHAO Yan-ming |
Nanjing University of Science and Technology, Nanjing 210094, China |
|
|
Abstract The end-point control of basic oxygen gurnace (BOF) consists of temperature control and element control. The flame of converter can reflect the decarburization rate and operation parameters of converter. The atomic emission spectra of alkali metals such as kalium and sodium exist in the boiler flames, the temperature of flame can be calculated with the spectral line inversion technique. Two-color method, three-color method and two-line method are used to calculate the flame temperature. The characteristic lines are extracted from the fitting baseline and the wavelet ridge line fitting baseline. Characteristic spectral lines are fitted with Gauss function and Lorenz function. The results show that the radiation thermometry is sensitive to the spectral lines, the reasonable band is necessary to measure the flame temperature effectively and accurately. Two-line method is limited by mathematical model of characteristic spectral line, transition probability of spectral line, degenerate degree of energy level, optical thickness of flame. High resolution spectrometer is necessary to measure the converter flame temperature.
|
Received: 2015-12-28
Accepted: 2016-04-09
|
|
Corresponding Authors:
ZHAO Qi
E-mail: zslzhaoqi@163.com
|
|
[1] LIN Teng-chang,ZHU Rong,ZENG Jia-qing(林腾昌,朱 荣,曾加庆). Journal of Iron and Steel Research(钢铁研究学报),2016,28(3):48.
[2] ZHANG Xiang-yu,LÜ Wei,ZHOU Huai-chun,et al(张向宇,吕 伟,周怀春,等). Journasl of Combustion Science and Technology(燃烧科学与技术),2014,20(2): 115.
[3] Rego-Barcena S,Mani R,Yang F,et al. Metallurgical and Materials Transactions B,2009,40(2):158.
[4] SANG Tao,HAO Xiao-jian(桑 涛,郝晓剑). Electro-Optic Technology Application(光电技术应用),2015,30(6): 14.
[5] James-Geddis P. Toronto:University of Toronto,2009.
[6] YU Wei-xiong,DAI Jing-ming,WANG Yong(于为雄,戴景民,王 勇). Infrared and Laser Engineering(红外与激光工程),2014,5: 1390.
[7] Snowper T,Zeltner D,Tree D R,et al. Applied Energy,2012,95(2):38.
[8] Zhang B,Yu H,Sun L,et al. Applied Spectroscopy,2013,67(9):1087.
[9] PENG Zhi-min,DING Yan-jun,ZHAI Xiao-dong(彭志敏,丁艳军,翟晓东). Acta Physica Sinica(物理学报),2011,60(10):454. |
[1] |
ZHANG Nan-nan1, 3, CHEN Xi-ya1,CHANG Xin-fang1, XING Jian1, GUO Jia-bo1, CUI Shuang-long1*, LIU Yi-tong2*, LIU Zhi-jun1. Distributed Design of Optical System for Multi-Spectral Temperature
Pyrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 230-233. |
[2] |
GAO Wei-ling, ZHANG Kai-hua*, XU Yan-fen, LIU Yu-fang*. Data Processing Method for Multi-Spectral Radiometric Thermometry Based on the Improved HPSOGA[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3659-3665. |
[3] |
WANG Wen-song1, PEI Chen-xi2, YANG Bin1*, WANG Zhi-xin2, QIANG Ke-jie2, WANG Ying1. Flame Temperature and Emissivity Distribution Measurement MethodBased on Multispectral Imaging Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3644-3652. |
[4] |
LIU Hong-wei1, FU Liang2*, CHEN Lin3. Analysis of Heavy Metal Elements in Palm Oil Using MP-AES Based on Extraction Induced by Emulsion Breaking[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(10): 3111-3116. |
[5] |
LIU Pan1, 2, 3, DU Mi-fang1*, LI Bin1, LI Jing-bin1, ZENG Lei1, LIU Guo-yuan1, ZHANG Xin-yao1, 4, ZHA Xiao-qin1, 4. Determination of Trace Tellurium Content in Aluminium Alloy by
Inductively Coupled Plasma-Atomic Emission Spectrometry Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(10): 3125-3131. |
[6] |
XING Jian, LIU Zhi-jun, HAN Bing, HAO Xiang-wei*. Multi-Spectral True Temperature Inversion Algorithm Based on
Generalized Inverse Matrix-Coordinate Rotation Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1936-1940. |
[7] |
HAO Jun1, WANG Yu2, LIU Cong2, WU Zan2, SHAO Peng2, ZU Wen-chuan2*. Application of Solution Cathode Glow Discharge-Atomic Emission Spectrometry for the Rapid Determination of Calcium in Milk[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(12): 3797-3801. |
[8] |
ZHENG Pei-chao, LUO Yuan-jiang, WANG Jin-mei*, HU Qiang, YANG Yang, MAO Xue-feng, LAI Chun-hong, FENG Chu-hui, HE Yu-tong. Determination of Strontium in Strontium-Rich Mineral Water Using Solution Cathode Glow Discharge-Atomic Emission Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(01): 272-276. |
[9] |
LI Ai-yang1, FU Liang2*. Study on the Analysis Total As in Bentonite With Microwave Plasma Atomic Emission Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(12): 3671-3675. |
[10] |
LIU Hong-wei1,3, FU Liang2*. Analysis of Metal Impurity Elements in Li4Ti5O12 Through Microwave Plasma Atomic Emission Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3021-3025. |
[11] |
LI Zheng-kai1, CHEN Lei1*, YANG Cong1, SONG Peng2, 3, ZENG Wen1, LIU Ai-guo1, PANG Jun-yi1. A Study on Emission Spectral Diagnosis of Ar/CH4 Plasma Jet[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1398-1403. |
[12] |
CHAI Xiao-li1, 2, 4, GAO Dan-dan1, 2, LI Hai-jun1, WANG Bo1, YANG Ke-li1,2, DONG Ya-ping1, 2*, LI Wu1, 3. Rapid Determination of Trace Iodine in Oilfield Brine Based on Oxidation-Atomic Emission Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1574-1579. |
[13] |
XING Jian1, MA Zhao2, BAI Yan1*. Multi Spectral Radiation External Penalty Function Inversion Algorithm for Flame Temperature Measurement of Biomass Boiler[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3761-3764. |
[14] |
LIU Wen-ke1, 2*, ZHANG Yu-bin2, ZHA Ling-yan2. Effect of LED Red and Blue Continuous Lighting before Harvest on Growth and Nutrient Absorption of Hydroponic Lettuce Cultivated under Different Nitrogen Forms and Light Qualities[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(07): 2215-2221. |
[15] |
XIAN Yi-heng1,2, LI Xin-tong1,2, ZHOU Xue-qi3, MA Jian1, LI Yan-xiang4, WEN Rui1,2. Study on Chemical Composition and Provenience Differentiation of Turquoises Excavated from Two Sites in Xinjing[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(03): 967-970. |
|
|
|
|