光谱学与光谱分析 |
|
|
|
|
|
A Novel Flow Injection Chemiluminescence Method with Ferricyanide and Luminol for the Determination of Ractopamine in Biological Samples |
FENG Ting, HU Yu-fei*, LI Gong-ke* |
School of Chemistry and Chemical Engineering,Sun Yat-sen University,Guangzhou 510275, China |
|
|
Abstract A novel chemiluminescence method coupled with flow injection technique for the determination of ractopamine was developed. It was based on the enhancement of the chemiluminescence by ractopamine derived from the chemiluminescence reaction between luminol and ferricyanide in sodium hydroxide medium. The linear calibration range of the chemiluminescence intensity with respect to the ractopamine concentration covers from 4.0×10-9~8.0×10-7 g·mL-1. The relative standard deviation for ractopamine is 5.6% (n=11), and the detection limit is 2.5×10-9 g·mL-1. The method was firstly applied to the determination of ractopamine in biological samples with satisfactory results. The recovery was between 69.3% and 101.3%.
|
Received: 2011-04-22
Accepted: 2011-08-18
|
|
Corresponding Authors:
HU Yu-fei, LI Gong-ke
E-mail: cesgkl@mail.sysu.edu.cn; huyufei@mail.sysu.edu.cn
|
|
[1] Kuiper H A, Noordam M Y, Van Dooren-Flipsen M M, et al. J. Anim. Sci.,1998, 76(1): 195. [2] KONG Ling-yong, PENG Hui-jian, HE Gen-shan, et al(孔令勇,彭会建,何根山,等). Guangdong Feed(广东饲料), 2006, 8(15): 31. [3] SUN Jian-wen, PENG Zhi-ni, WANG Qian, et al(孙建文,彭志妮,王 乾,等). Chinese Journal of Analysis Laboratory(分析试验室), 2008, 27(9): 90. [4] Xu Z G, Hu Y F, Hu Y L, et al. J. Chromatogr. A,2010, 1217(22): 3612. [5] Wang J P, Li X W, Zhang W, et al. Chromatographia,2006, 64(9): 613. [6] He L M, Su Y J, Zeng Z L, et al. Anim. Feed. Sci. Technol.,2007, 132(3-4): 316. [7] Peters R J B, Oosterink J E, Stolker A A M, et al. Anal. Bioanalytical Chem.,2010, 396(7): 2583. [8] Blanca J, Munoz P, Morgado M, et al. Anal. Chim. Acta,2005, 529(1-2): 199. [9] Li C, Wu Y L, Yang T, et al. J. Chromatogr. A,2010, 1217(50): 7873. [10] WU Ping-gu, YING Yong-fei, CHEN Hui-hua(吴平谷,应永飞,陈慧华). Chinese Journal of Analytical Chemistry(分析化学), 2007, 35(3): 330. [11] Petz M. Monatsh Chem.,2009, 140(8): 953. [12] Shen L, He P L. Electrochem. Commun.,2007, 9(4): 657. [13] Wang W, Zhang Y, Wang J, et al. Meat Sci.,2010, 85(2): 302. [14] Zhang M Z, Wang M Z, Chen Z L, et al. Anal. Bioanalytical Chem.,2009, 395(8): 2591. [15] GAO Yi-ming, WU Yan-tao, WANG Shou-li, et al(高以明,吴艳涛,王寿利,等). Chinese Journal of Animal Health Inspection(中国动物检疫), 2009, 26(12): 37.
|
[1] |
ZHENG Pei-chao, ZHONG Chao, WANG Jin-mei*, LUO Yuan-jiang, LAI Chun-hong, WANG Xiao-fa, MAO Xue-feng. Evaluation of Flow Injection-Solution Cathode Glow Discharge With an Interference Filter Wheel for Spectral Discrimination[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(03): 842-847. |
[2] |
ZHOU Ying1, BAI Yong-hui1, SONG Xu-dong1*, YAO Min3, WANG Jiao-fei1, SU Wei-guang1, YU Guang-suo1,2*. Application of Chemiluminescence in Spectral Diagnosis: A Review[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(11): 3358-3364. |
[3] |
WU Sheng-yang1,2, HU Ren-zhi1,2*, XIE Pin-hua1,2, LI Zhi-yan1,2, LIU Xiao-yan3, LIN Chuan1,4, CHEN Hao1,2, WANG Feng-yang1,2, WANG Yi-hui1,5, JIN Hua-wei1,2. Real-Time Measurement of NOy (Total Reactive Nitrogen Oxide) by Cavity Ring Down Spectrometer (CRDS)[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(06): 1661-1667. |
[4] |
LIU Yao, TAN Jian-guo*, GAO Zheng-wang. College of Aerospace Science and Engineering, National University of Defense Technology, Changsha 410073, China[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(04): 1018-1022. |
[5] |
WANG Zhong-yuan1, ZHANG Hong-kang2*, NI Zhi-xin1, LIU Jing-qin1, CHEN Xin1, LI Sheng-yong1, YANG Qi-jin2, ZHANG Can1. FI-KR-FAAS Twice Gas Isolation Elution Method for the Determination of Trace Lead in Marine Biological Samples[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(11): 3578-3582. |
[6] |
CAO Xuan1,2, CHU Dong-zhi1,2, LIU Yan1,2*, MA Ran1,2, ZHANG Shu-wei1,2, WU Ning1,2, SHI Qian1,2, MA Hai-kuan1,2. An On-Line Microfluidic Analysis System for Seawater Chemical Oxygen Demand Using Ozone Chemiluminescence[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3698-3702. |
[7] |
AN Xue-jing, LUO Yun-jing*, ZHANG Chen-yang. Research on the Reaction Dynamics between Peroxynitrite and Tyrosine Catalyzed with Mimic Enzyme through Flow Injection Analyzer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(12): 4052-4057. |
[8] |
WANG Song-bai1, ZHANG Yan1, WEI Yan-li1, AN Wen-ting1, WANG Yu2*, SHUANG Shao-min1* . Fluoroimmunoassay and Magnetic Lateral Flow Immunoassay for the Detection of Ractopamine[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(11): 3100-3104. |
[9] |
ZHENG Zhi-yuan1, 2, 3, DU Yu-zhi1, 2, ZHANG Ming1, 2, 3, YU Ming-jie1, 2, 3, LI Cen1, 2, 3, YANG Hong-xia1, 2, ZHAO Jing1, 2, 3, XIA Zheng-hua1, 2, 3, WEI Li-xin1, 2*. Study on Content Determination of Lead and Arsenic in Four Traditional Tibetan Medicine Prescription Preparations by Wet Digestion Flow Injection-Hydride Generation-Atomic Absorption Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(04): 1037-1042. |
[10] |
ZHAO Jin-hui, YUAN Hai-chao, LIU Mu-hua*, XIAO Hai-bin, HONG Qian . Rapid Determination of Ractopamine Content in Pork by Using Three-Dimensional Synchronous Fluorescence Spectrum Coupled with APTLD[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(04): 1012-1016. |
[11] |
CAO Jun-tao1, WANG Hui1, CHEN Yong-hong2, LIU Yan-ming1* . Sensitive Determination of Hemoglobin in Human Blood and Serum by Flow Injection Coupled with Chemiluminescence Detection [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(01): 241-245. |
[12] |
CUI Jian1, 2, ZHAO Xue-hong1*, WANG Yan1, XIAO Ya-bing3, JIANG Xue-hui1, DAI Li1 . Research on Optimization of Mathematical Model of Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(01): 246-251. |
[13] |
WANG Yi-ru, LIU Hai-feng, ZHANG Hong-cai, LIU Guo-yan, CHAI Chun-yan* . Preparation and Characteristic Analysis of Ractopamine Molecularly Imprinted Polymers[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(10): 2629-2632. |
[14] |
DU Jun-jun1, WANG Hui1, REN Shu-wei2, ZHOU Min1, LIU Ying-ying1, LIU Yan-ming1* . Sensitive Determination of Bovine Serum Albumin by Flow-Injection Chemiluminescence [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(06): 1693-1696. |
[15] |
WANG Zhong-yuan1, ZHANG Hong-kang2*, FANG Hong-da1, SU Yao-dong3, Gauri S Mittal4 . FI-KR Non-Separated Method Coupled with FAAS for the Determination of Fe(Ⅱ) and Fe(Ⅲ) in Water [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(03): 817-820. |
|
|
|
|