Abstract In order to miniaturize an infrared spectrometer, we analyze the current optical design of miniature spectrometers and propose a method for designing a miniature infrared gratings spectrometer based on planar waveguide. Common miniature spectrometer uses miniature optical elements to reduce the size of system, whichalso shrinks the effective aperture. So the performance of spectrometer has dropped. Miniaturization principle of planar waveguide spectrometer is different from the principle of common miniature spectrometer. In planar waveguide spectrometer, the propagation of light is limited in a thin planar waveguide, which looks like the whole optical system is squashed flat. In the direction parallelto the planar waveguide, the light through the slit is collimated, dispersed and focused. And a spectral image is formed in the detector plane. This propagation of light is similar to the light in common miniature spectrometer. In thedirection perpendicular to the planar waveguide, light is multiple reflected by the upper and lower surfaces of the planar waveguide and propagates in the waveguide. So the size of corresponding optical element could be very small in thevertical direction, which can reduce the size of the optical system. And the performance of the spectrometer is still good. The design method of the planar waveguide spectrometer can be separated into two parts, Czerny-Turner structure design and planar waveguide structure design. First, by using aberration theory an aberration-corrected (spherical aberration, coma, focal curve) Czerny-Turner structure is obtained. The operation wavelength range and spectral resolution are also fixed. Then, by using geometrical optics theory a planar waveguide structure is designed for reducing the system size and correcting the astigmatism. The planar waveguide structure includes a planar waveguide and two cylindrical lenses. Finally, they are modeled together in optical design softwareand are optimized as a whole. An infrared planar waveguide spectrometer is designed using this method. The operation wavelength range is 8~12 μm, the numerical aperture is 0.22, and the linear array detector contains 64 elements. Byusing Zemax software, the design is optimized and analyzed. The results indicate that the size of the optical system is 130 mm×125 mm×20 mm and the spectral resolution of spectrometer is 80 nm, which satisfy the requirements of designindex. Thus it is this method that can be used for designing a miniature spectrometer without movable parts and sizes in the range of several cubic centimeters.
|
Received: 2014-03-12
Accepted: 2014-06-18
|
|
Corresponding Authors:
FANG Yong-hua
E-mail: yhfang@aiofm.ac.cn
|
|
[1] Kruzelecky R V, Ghosh A K. Proc. SPIE, 2001, 4205: 25. [2] Crocombe R A. Spectroscopy, 2008, 23(1): 38. [3] CHENG Liang(程 梁). Research and Application of Microspectrometers System(微型光谱仪系统的研究及其应用). Zhejiang: Zhejiang University, 2008. [4] JU Hui(鞠 挥). Study on Miniaturization of Spectrometer for Biochemical Use(用于生化分析的光谱仪微小型化的研究). Changchun: Changchun Institute of Optics, Fine Mechanics and Physics, 2000. [5] Daly J T, Johnson E A, Bodkin W A, et al. Proc. SPIE,2000, 3953: 70. [6] Chadha S, Henning P F, Weling A S, et al. Proc. SPIE, 2003, 5085: 75. [7] Kruzelecky R V, Haddad E, Wong B, et al. Miniature High-Performance Infrared Spectrometer for Space Applications,2004, 554: 203. [8] Moran-Iglesias C J, Last A, Mohr J. Proc. SPIE, 2005, 5962: 25. [9] Shafer A B, Megill L R, Droppleman L. JOSA, 1964, 54(7): 879. [10] Reader J. JOSA, 1969, 59(9): 1189. [11] XUE Qing-sheng, WANG Shu-rong, LU Feng-qin(薛庆生, 王淑荣,鲁凤芹). Acta Optica Sinica(光学学报), 2009, 29(1): 35. [12] LI Yang-yu, FANG Yong-hua, LIU Yang(李扬裕, 方勇华, 刘 洋). Journal of Atmospheric and Environmental Optics(大气与环境光学学报), 2012, 7(4): 315. [13] Lee K S, Thompson K P, Rolland J P. Optics Express, 2010, 18(22):23378. [14] ZHANG Yi-mo(张以谟). Applied Optics(应用光学). Beijing: Publishing House of Electronics Industry, 2010. 26, 55. |
[1] |
LI Xin-quan1, 2,ZHANG Jun-qiang1, 3*,WU Cong-jun1,MA Jian1, 2,LU Tian-jiao1, 2,YANG Bin3. Optical Design of Airborne Large Field of View Wide Band Polarization Spectral Imaging System Based on PSIM[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 250-257. |
[2] |
SHEN Chun-yang1, 2, CUI Ji-cheng1*, SUN Ci1, WANG Wei1, 2, CHEN Jian-jun1, 2, LI Xiao-tian1. A Detection System Design of Echelle Diffraction Efficiency and Stray Coefficient[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2603-2609. |
[3] |
ZHENG Zhi-zhong1,2, YANG Zhong1*, XIU Lian-cun2, DONG Jin-xin2, CHEN Chun-xia2, GAO Yang2, YU Zheng-kui2. Design of a SWIR Offner Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2267-2272. |
[4] |
PEI Lin-lin1, XIANGLI Bin1, 2, LIU Yang-yang2*, Lü Qun-bo2, SHAO Xiao-peng1 . The Snapshot Imaging Spectrometer with Image Replication Based on Wallaston Prism[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(12): 4105-4112. |
[5] |
LIU Yu-juan1, WANG Cheng-ming1, LIN Jun1*, CUI Ji-cheng2, ZHANG Tian-yu1*, ZHONG Zhi-cheng1* . Optimal Design of Light Folding Imaging Spectrometer Based on Dyson Concentric System [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(07): 2287-2290. |
[6] |
YANG Zeng-peng1, 2, TANG Yu-guo1, Bayanheshig1, CUI Ji-cheng1, YANG Jin1 . Research on Small-Type and High-Spectral-Resolution Grating Monochromator[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(01): 273-278. |
[7] |
LIU Yi-xuan1, 2, YAN Chang-xiang1* . Design of Dual-Beam Spectrometer in Spectrophotometer for Colorimetry [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(07): 2060-2064. |
[8] |
YAN Ling-wei . Study on the Advanced Czerny-Turner Imaging Spectrometer with High Resolution in Broadband [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(06): 1756-1760. |
[9] |
WU Cong-jun1,2, YAN Chang-xiang1*, LIU Wei1, DAI Hu1,2 . Sub-Field Imaging Spectrometer Design Based on Offner Structure [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(08): 2272-2276. |
[10] |
XUE Qing-sheng, WANG Shu-rong . Optimum Design of Imaging Spectrometer Based on Toroidal Uniform-Line-Spaced (TULS) Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(05): 1433-1437. |
[11] |
GAO Jing1,2, LU Qi-peng1*, PENG Zhong-qi1, DING Hai-quan1, GAO Hong-zhi1 . Design of High-Efficiency Double Compound Parabolic Concentrator System in Near Infrared Noninvasive Biochemical Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(05): 1406-1410. |
[12] |
FANG Yu1, 2, XIANGLI Bin3, YUAN Yan4, Lü Qun-bo3, ZHOU Jin-song3 . Design of the Airborne Prism Dispersive Imaging Spectrometer System Based on Offner Relay Configuration [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(03): 838-843. |
[13] |
NING Chun-li1, 2, QI Xiang-dong1, CHEN Shao-jie1, 2, Bayanheshig1, CUI Ji-cheng1, 2 . Optical Design and Performance Analysis of Light and Small Echelle Spectrograph[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(12): 3406-3410. |
[14] |
KOU Jie-ting1,2, Bayanheshig1*, TANG Yu-guo1, QI Xiang-dong1, YU Hong-zhu1 . Wavelength Calibration Research on the Automatic Grating Monochromator for Orthogonal Czerny-Turner Structure[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(04): 1127-1131. |
[15] |
LIU Zhuang1,2, GONG Yan1. Design of Optical System for Solar Extreme-Ultraviolet Imaging Spectrometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(03): 834-838. |
|
|
|
|