|
|
|
|
|
|
A Method Quickly to Measure the Size of the Confocal Volume of Confocal X-Ray Instrument |
SUN Xue-peng1, 2, ZHANG Xiao-yun1, 2, SHAO Shang-kun1, 2, WANG Ya-bing1, 2, LI Hui-quan1, 2, SUN Tian-xi1, 2* |
1. Laboratory of Beam Technology of Ministry of Education, College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875, China
2. Beijing Radiation Center, Beijing 100875, China |
|
|
Abstract Confocal X-ray fluorescence is a directly non-destructive analysis technique with spatial resolution, widely used in materials, biology, mineral sample analysis, archaeology, evidence traceability and other fields. The confocal X-ray fluorescence spectrometer work is based on a polycapillary X-ray lens. A polycapillary focusing X-ray lens (PFXRL) attached to the X-ray tube is used to focus the divergent X-ray from the X-ray tube to the output focal spot with dozens of micron diameter and high power density gain. A polycapillary parallel X-ray lens (PPXRL) with an input focal spot placed on the front of the silicon drift detector is used to receive the fluorescence signal from the specific region. The overlap region of the output focal spot of the PFXRL and the input focal spot of the PPXRL in the confocal X-ray fluorescence spectrometer is called probe volume. Only the sample in the probe volume can be detected. The spatial information of the sample can be obtained by the relative movement of the probe volume and sample point by point. The size of the probe volume determines the spatial resolution of the confocal X-ray fluorescence spectrometer. Thus, it is significant to measure the size of the probe volume. The shape of the probe volume is similar to an ellipsoid. The size of the probe volume can be expressed as the horizontal resolution X, Y and the depth resolution Z, as showni n Fig.1. The detail size of the probe volume of the confocal X-ray instrument is commonly measured by the metal wire ormetal film using the knife scanning method. To precisely measure the probe volume size, the diameter of the metal wire prefer small than the probe volume size. It is difficult to place the metal wire close to the probe volume because the probe volume size and mental wire diameter are dozens of microns. According to obtain the changing curve of the probe volume size and the energy of the incident X-ray beam, various metal wires were used, which is a waste of time. The metal film is suitable for measuring the depth resolution of the probe volume (Z). However, it is difficult for the metal film to measure the horizontal resolution of the probe volume (X, Y). To solve the problem mentioned above, a special sample of series metal wires stick on paper was used to measure the size of the confocal volume of the confocal X-ray instrument. To adjusting the special sample close to the probe volume, the probe volume can be placed in the plane of the paper. With the assistance of the digital camera, the metal wire can be rapidly placed close to the probe volume. After putting the metal wire close to the probe volume, two-dimensional scanning is performed along with two directions of the probe volume with the help of the motorized translation stage. The changing curve of the probe volume and incident X-ray energy was obtained by processing the data obtained from the two-dimensional scanning. In this study, the probe volume size of the confocal X-ray instrument in our laboratory was measured by the method proposed above.
|
Received: 2020-10-23
Accepted: 2021-03-03
|
|
Corresponding Authors:
SUN Tian-xi
E-mail: stxbeijing@163.com
|
|
[1] Kanngießer B,et al. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2003, 211(2): 259.
[2] Mihucz V G, et al. Food Chemistry, 2010, 121(1): 290.
[3] Peng S, et al. Analytical Chemistry, 2014, 86(1): 362.
[4] PENG Song, LIU Zhi-guo, SUN Tian-xi, et al(彭 松, 刘志国, 孙天希, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2013, 33(8): 2223.
[5] Torre-Fdez I, et al. Analytical and Bioanalytical Chemistry, 2018, 410(28): 7477.
[6] Mazel V, et al. Talanta, 2011, 85(1): 556.
[7] Gibson W M, Kumakhov M A. Proceedings of SPIE, 1993, 1736: 172.
[8] Woll A R, Mass J, Bisulca C, et al. Applied Physics A, 2006, 83(2): 235.
[9] Sun T, et al. Spectrochimica Acta Part B: Atomic Spectroscopy, 2008, 63(1): 76.
[10] Hampai D, et al. Optics Letters, 2008, 33(23): 2743.
[11] Silversmit G, et al. Analytical Chemistry, 2011, 83(16): 6294.
[12] Liu H, et al. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013, 723: 1.
[13] Sun T, MacDonald C A. Journal of Applied Physics, 2013, 113(5): 053104.
[14] Li F, Liu Z, Sun T. Food Chemistry, 2016, 210: 435.
[15] Sun W, et al. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014, 764: 1.
[16] Mantouvalou I, Malzer W, Kanngießer B. Spectrochimica Acta Part B: Atomic Spectroscopy, 2012, 77: 9.
[17] Lin X, et al. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2008, 266(11): 2638.
[18] Malzer W, Kanngieβer B. Spectrochimica Acta Part B: Atomic Spectroscopy, 2005, 60(9-10): 1334.
[19] Tsuji K, Nakano K. Journal of Analytical Atomic Spectrometry, 2011, 26(2): 305.
[20] Sun T, Ding X. Journal of Applied Physics, 2005, 97(12): 124904. |
[1] |
YANG Ya-fei1, 2, ZHANG Cai-xin1*, CHEN Hua1, ZHANG Wei-bin1, TIAN Yong1, ZHANG Ding-hua2, 3, HUANG Kui-dong2, 3*. Effective Atomic Number Measurement of Energetic Material Using
Photon Counting Spectral Computed Tomography[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(05): 1400-1406. |
[2] |
PAN Qiu-li1, SHAO Jin-fa1, LI Rong-wu2, CHENG Lin1*, WANG Rong1. Non-Destructive Analysis of Red and Green Porcelain in Qing Dynasty[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(03): 732-736. |
[3] |
HUANG Yu-ying1, 2, 3, ZHONG Xin-yu2, 3. Progress of Synchrotron Radiation X-Ray Fluorescence Spectrometry in China and Overseas[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 333-340. |
[4] |
WANG Ya-bing1,2, SHAO Shang-kun1,2, SUN Xue-peng1,2, ZHANG Xiao-yun1,2, LI Hui-quan1,2, SUN Tian-xi1,2*. Determination of Parameters of X-Ray Source Based on Tapered Glass Monocapillary X-Ray Condenser[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2812-2816. |
[5] |
SU Ao1, LI Pei-jun2*, LEI Ming-zhu3, LIU Qiang4, ZHANG Xin5. Identifying Gas-Washing and Water-Washing of Oil Reservoirs by Fluorescence and Infrared Spectra of Single Oil Inclusion[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(08): 2649-2656. |
[6] |
ZHOU Yue1, 2, YAN Ling-tong1, LI Li1, SUN He-yang1, FENG Xiang-qian1*. The Progress of the Application of X-Ray Spectroscopy in the Nondestructive Analysis of Relics[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1329-1335. |
[7] |
MIAO Xin-yang1,2,3, LIU Xue-cong1,3, CHEN Meng-xi3, CHEN Si-tong3, ZHANG Shan-zhe1, LU Wan-ting3, PENG Xue3, ZHAN Hong-lei2,3, ZHU Ming-da1, ZHAO Kun1,2,3*. Terahertz Spectral Characteristics of Rocks With Different Lithologies[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(04): 1314-1319. |
[8] |
LUO Li-qiang, SHEN Ya-ting. Advantages of X-Ray Spectrometry in Origin of Life, Earth Life on Earth and Global Climate Change[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(03): 665-674. |
[9] |
Moamen S. Refat1*, Amnah M. Alsuhaibani2, Mohamed Nagaty1. Infrared Spectroscopy and Morphological Assessments on the Nutritional Value of Prickly Pear Fruit[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(02): 648-653. |
[10] |
SHAO Shang-kun1, 2, SUN Xue-peng1, 2, DU Xiao-guang3, LI Yu-fei1, 2, WANG Ya-bing1, 2, ZHANG Xiao-yun1, 2, LIU Zhi-guo1, 2, SUN Tian-xi1, 2*. Identification of Pearl Based on X-Ray Transmission Imaging and Fluorescence Dual Mode[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3936-3940. |
[11] |
DING Ji-gang1, HAN Dong-hai1, LI Yong-yu1*, PENG Yan-kun1, WANG Qi1, HAN Xi2. Simultaneous Non-Destructive On-Line Detection of Potato Black-Heart Disease and Starch Content Based on Visible/Near Infrared Diffuse Transmission Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(06): 1909-1915. |
[12] |
CAI Shun-yan1, 2, ZHOU Jian-bin1*, TUO Xian-guo1, YU Jie1. Optimized Filter Selection for Measuring Copper and Molybdenum Contents by EDXRF[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(06): 1934-1939. |
[13] |
Soo Hyun Park1, 3, Youngki Hong2, Mubarakat Shuaibu1, Sangcheol Kim2, Won Suk Lee1*. Detection of Apple Marssonina Blotch with PLSR, PCA, and LDA Using Outdoor Hyperspectral Imaging[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(04): 1309-1314. |
[14] |
GE Tao1,3, CAI Chuan-chuan1, CHEN Ping3, MIN Fan-fei1, ZHANG Ming-xu1. The Characterization on Organic Sulfur Occurrence in Coking Coal and Mechanism of Microwave Actionon Thiophene[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(04): 1321-1327. |
[15] |
ZHAO Yao-xia, HAN Yan, CHEN Ping*. Blind Separation of Multi-Voltage Projection Sequence Based on Fundamental Effect Decomposition[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(09): 2763-2768. |
|
|
|
|