Study on Effective Wavelength Calibration Method of Multispectral Pyrometer |
LIANG Mei1, SUN Bo-jun1, SUN Xiao-gang1*, XIE Jun-yan2, YU Chen-tao1 |
1. School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150001, China
2. Xi’an Aerospace Power Institute of Measurement and Control Technology, Xi’an 710025, China |
|
|
Abstract For the problem that the effective wavelength cannot be obtained because the signal is too weak due to fiber coupling during wavelength calibration of optical fiber multi-spectral pyrometer, a new effective wavelength determination method is proposed based on the data of temperature calibration. Based on the Planck’s law, a new method for solving the wavelength is presented, combining with the calibration value ratios of different calibration temperature points. Compared with the traditional method of effective wavelength calibration, the new method proposed in this paper not only provides a new way to get the effective wavelength fast, but also avoids the complexity of the wavelength calibration process. Simulation and experiment were used in this paper to verify the feasibility and effectiveness of the new method. The simulation results showed that the new method which was feasible to get the effective wavelength had the anti-random error ability, and the relative error between the true temperature calculation value based on the effective wavelength and the actual value was less than 0.7%. The experimental results showed that the new method could get the effective wavelength of each channel, and further verify the effectiveness of the proposed method. The new method proposed in this paper can also be applied to other multi-spectral pyrometer, providing a theoretical basis for the development and application of the multi-spectral pyrometer.
|
Received: 2016-06-23
Accepted: 2016-10-10
|
|
Corresponding Authors:
SUN Xiao-gang
E-mail: sxg@hit.edu.cn
|
|
[1] Coates P. Metrologia,1981,17: 103.
[2] Khan M A, Allemand C, Eagar T W. Review of Scientific Instruments, 1991, 62: 392.
[3] Wang Y L, Luan M S, Yu T Y. Infrared Technology, 2009, 7: 8.
[4] Fu T, Liu J, Tang J, et al. Infrared Physics & Technology,2014,66: 49.
[5] Fu T, Duan M, Liu J, et al. Infrared Physics & Technology 2014,67: 590.
[6] Zhang Fucai, Sun Xiaogang, Xing Jian. Spectroscopy and Spectral Analysis,2016,36(5): 1598.
[7] Coppa P, Ruffino G, Spena A. High Temperatures. High Pressures,1988,20: 479.
[8] Coppa P, Jinmin D, Ruffino G. International Journal of Thermophysics,1993,14: 599.
[9] Sun X G, Yuan G B, Dai J M, et al. International Journal of Thermophysics,2005,26: 1255.
[10] SUN Xiao-gang, DAI Jing-min(孙晓刚, 戴景民). Journal of Infrared and Millineter Waves(红外与毫米波学报), 2003, 22: 141.
[11] Hattori S. Journal of the Society of Instrument and Control Engineers,1982,21: 1014. |
[1] |
XU Qiu-yi1, 3, 4, ZHU Wen-yue3, 4, CHEN Jie2, 3, 4, LIU Qiang3, 4 *, ZHENG Jian-jie3, 4, YANG Tao2, 3, 4, YANG Teng-fei2, 3, 4. Calibration Method of Aerosol Absorption Coefficient Based on
Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 88-94. |
[2] |
WANG Zhen-tao1, DAI Jing-min1*, YANG Sen2. Research on Multi-Spectral Thermal Imager Explosion Flame True
Temperature Field Measurment[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3885-3890. |
[3] |
WANG Yi-hong, ZHOU Bin*, ZHAO Rong, WANG Bu-bin. Calibration-Free Wavelength Modulation Spectroscopy for Gas Properties Measuring Basedon 2nd and 4th Harmonics[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(02): 368-373. |
[4] |
YANG Hua-dong1, 2, ZHU Hao1, 2, WANG Zi-chao1, 2, LIU Zhi-ang1, 2. Research on On-Line Monitoring Technology of Water Sediment
Concentration Based on Transmission Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(12): 3817-3822. |
[5] |
ZHAO Yu-hui,LIU Xiao-dong,ZHANG Lei,LIU Yong-hong. Research on Calibration Transfer Method Based on Joint Feature Subspace Distribution Alignment[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(11): 3411-3417. |
[6] |
ZHAO Yu-hui, LU Peng-cheng, LUO Yu-bo, SHAN Peng. NIR Calibration Transfer Method Based on Minimizing Mean Distribution Discrepancy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3051-3057. |
[7] |
WU Lu-yi, GAO Guang-zhen, LIU Xin, GAO Zhen-wei, ZHOU Xin, YU Xiong, CAI Ting-dong*. Study on the Calibration of Reflectivity of the Cavity Mirrors Used in Cavity Enhanced Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2945-2949. |
[8] |
WANG Yi-hui1, 2, HU Ren-zhi2*, XIE Pin-hua2, 3, 4*, WANG Feng-yang1, 2, ZHANG Guo-xian1, 2, LIN Chuan1, 2, LIU Xiao-yan5, WANG Yue2. The Study of Turbulent Calibration System of HOx Radical Detection[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(08): 2384-2390. |
[9] |
SU Wei1,2, WU Jia-yu1,2, WANG Xin-sheng1,2, XIE Zi-xuan1,2, ZHANG Ying1,2, TAO Wan-cheng1,2, JIN Tian1,2. Retrieving Corn Canopy Leaf Area Index Based on Sentinel-2 Image and PROSAIL Model Parameter Calibration[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(06): 1891-1897. |
[10] |
SUN Bo-jun, SUN Xiao-gang*, DAI Jing-min. Fast Inversion Method of Multispectral True Temperature[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1336-1342. |
[11] |
CHEN Hao1, 2, JU Yu3, HAN Li1, CHANG Yang3. Curve Fitting of TDLAS Gas Concentration Calibration Based on Relative Error Least Square Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1580-1585. |
[12] |
YANG Zong-ju1, DAI Jing-min1*, YANG Lin2, WANG Zheng-tao1. A Multi-Spectral Pyrometer for Measuring Cathode Temperature Field of Vacuum Arc Plasma Discharge[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(01): 60-64. |
[13] |
JU Yu1,CHEN Hao2, 3,HAN Li2,CHANG Yang1, ZHANG Xue-jian1. Based on TDLAS Technology Gas Concentration Calibration Algorithm for a Large Range[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3665-3669. |
[14] |
ZHANG Fu-cai1, 2, TANG Wei1, SUN Xiao-gang2*. Multispectral True Temperature Inversion Based on Multi-Objective Minimum Optimization Principle of Reference Temperature[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 3130-3135. |
[15] |
WANG Zi-ang, LI Gang, LIU Bing-qi, HUANG Fu-yu*, CHEN Yi-chao. Extrinsic Parameters Calibration of Ultra-Wide Angle Long-Wave Infrared Stereo Vision and Evaluation of Intrinsic and Extrinsic Parameters[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(09): 2670-2675. |
|
|
|
|