光谱学与光谱分析 |
|
|
|
|
|
The Research of Oxygen Measurement by TDLAS Based on Levenberg-Marquardt Nonlinear Fitting |
YAN Jie, ZHAI Chang, WANG Xiao-niu, HUANG Wen-ping |
Anhui WAYEE Science and Technology Ltd., Hefei 230088, China |
|
|
Abstract Oxygen concentration is an important monitoring parameter in industrial process. Wavelength modulation spectroscopy of tunable diode laser absorption spectroscopy (TDLAS)was used to measure concentration of oxygen gas in industrial process by online monitoring. In this paper, we use the characteristic absorption peak of Oxygen at 760 nm to measure the oxygen concentration. Because of the strong coherence of laser, the detection sensitivity of TDLAS is severely restricted by optical interference noise. Especially at low concentrations, there is larger error by extraction signal in the absorption peak waveform because of the background fluctuation caused by optical interference. In response to this situation, Levenberg-Marquardt nonlinear fitting algorithm was proposed, and the use of the absorption line-derivative form of Lorenz line to fit the second harmonic signal and to extract the peak amplitude. On the other hand, Levenberg-Marquardt nonlinear fitting method needs a large amount of calculation. In order to develop the TDLAS analyzer can achieve real-time monitoring of the site, we use the C28 series of DSQ for data processing which support floating-point arithmetic, and the instrument achieve real-time monitoring capabilities in industrial process. Experimental results show that the algorithm can effectively extract the absorption peak characteristic value of the 2nd harmonic signal and overcome the background noise, The ratio of calculated by algorithm to actual oxygen concentration is nearly 1.01,the linear error of the concentration measurement is 1.18%.
|
Received: 2014-04-28
Accepted: 2014-08-25
|
|
Corresponding Authors:
YAN Jie
E-mail: yanj@mail.ustc.edu.cn
|
|
[1] Zappe H P, Hess M, Moser M, et al. Applied Optics, 2000, 39(15): 2475. [2] Awtry A R, Fisher B T, Moffatt R A, et al. Proceedings of the Combustion Institute, 2007, 31: 799. [3] Schlosser H E, Wolfrum J, Ebert V, et al. Proceedings of the Combustion Institute, 2002, 29: 353. [4] Verma R, Neethu S, Kamble S S, et al. Sensing Technology (ICST), 2012 Sixth International Conference on. IEEE, 2012. 130. [5] Neethu S, Verma R, Kamble S S, et al. Sensors and Actuators B: Chemical, 2014, 192: 70. [6] ZHANG Zhi-rong, WU Bian, XIA Hua, et al(张志荣,吴 边,夏 滑,等). Acta Physica Sinica(物理学报),2013,62(23): 2342041. [7] HE Jun-feng, KAN Rui-feng, XU Zhen-yu, et al(何俊峰,阚瑞峰,许振宇, 等). Acta Optica Sinica(光学学报),2014, 34(4): 04300036.
|
[1] |
ZHANG Le-wen1, 2, WANG Qian-jin1, 3, SUN Peng-shuai1, PANG Tao1, WU Bian1, XIA Hua1, ZHANG Zhi-rong1, 3, 4, 5*. Analysis of Interference Factors and Study of Temperature Correction Method in Gas Detection by Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 767-773. |
[2] |
SHAO Guo-dong1, LI Zheng-hui1, GUO Song-jie1, ZOU Li-chang1, DENG Yao1, LU Zhi-min1, 2, 3, YAO Shun-chun1, 2, 3*. Research on Gas Concentration Measurement Method Based on Gradient Descent Method to Fit Spectral Absorption Signal Directly[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3256-3261. |
[3] |
XIAO Hu-ying1, YANG Fan1, XIANG Liu1, HU Xue-jiao2*. Jet Vacuum Enhanced Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(10): 2993-2997. |
[4] |
LI Zheng-hui1,3, YAO Shun-chun1,3*, LU Wei-ye2, ZHU Xiao-rui1,3, ZOU Li-chang1,3, LI Yue-sheng2, LU Zhi-min1,3. Study on Temperature Correction Method of CO2 Measurement by TDLAS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(07): 2048-2053. |
[5] |
LI Meng, GUO Jin-jia*, YE Wang-quan, LI Nan, ZHANG Zhi-hao, ZHENG Rong-er. Study on TDLAS System with a Miniature Multi-Pass Cavity for CO2 Measurements[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(03): 697-701. |
[6] |
WANG Zhe1, WANG Yan1, ZHANG Rui2, ZHAO Xue-hong1*, LIU Qiao-jun2, LI Cong-rong2 . A Singular Value Decomposition Method for Tunable Diode Laser Absorption Spectroscopy System to Remove Systematic Noises[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(10): 3369-3376. |
[7] |
QI Ru-bin1, HE Shu-kai1, LI Xin-tian1, WANG Xian-zhong2 . Simulation of TDLAS Direct Absorption Based on HITRAN Database [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(01): 172-177. |
[8] |
CAI Ting-dong1, 2, GAO Guang-zhen1, WANG Min-rui1, WANG Gui-shi2, GAO Xiao-ming2 . Measurements of CO2 Concentration at High Temperature and Pressure Environments Using Tunable Diode Laser Absorption Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(07): 1769-1773. |
[9] |
LI Han, LIU Jian-guo, HE Ya-bai, HE Jun-feng, YAO Lu, XU Zhen-yu, CHEN Jiu-ying, YUAN Song, KAN Rui-feng* . Simulation and Analysis of Second-Harmonic Signal Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(04): 881-885. |
[10] |
GAO Nan1, DU Zhen-hui1*, TANG Miao2, YANG Jie-wen1, YANG Chun-mei1, WANG Yan1. System Parameters Selection and Optimization of Tunable Diode Laser Absorption Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30(12): 3174-3178. |
[11] |
ZHANG Shuai, DONG Feng-zhong*, ZHANG Zhi-rong,WANG Yu, KAN Rui-feng,ZHANG Yu-jun,LIU Jian-guo, LIU Wen-qing. Monitoring of Oxygen Concentration Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(10): 2593-2596. |
[12] |
TU Xing-hua, LIU Wen-qing, ZHANG Yu-jun, DONG Feng-zhong, WANG Min, WANG Tie-dong, WANG Xiao-mei, LIU Jian-guo. Second-Harmonic Detection with Tunable Diode Laser Absorption Spectroscopy of CO and CO2 at 1.58 μm[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26(07): 1190-1194. |
[13] |
KAN Rui-feng, LIU Wen-qing, ZHANG Yu-jun, LIU Jian-guo, WANG Min, GAO Shan-hu, CHEN Jun . Concentration Calibration Method of Ambient Trace-Gas Monitoring with Tunable Diode Laser Absorption Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26(03): 392-395. |
|
|
|
|