|
|
|
|
|
|
Mid-IR Laser Absorption Diagnosis on Flow Characteristics for Mars
Entry |
ZENG Hui, WEN Peng, YANG Guo-ming, ZHU Xing-ying, OU Dong-bin |
Beijing Key Laboratory of Arc Plasma Application Equipment, China Academy of Aerospace Aerodynamics, Beijing 100074, China
|
|
|
Abstract The Mars exploration mission is important to the national deep space exploration project. The successful landing of “Tianwen” on Mars in 2021 is a big step forward in China's space exploration and research on Mars. The Martian atmosphere is mainly dominated by carbon dioxide, and the surface pressure is much lower than the Earth's. Due to the differences in atmospheric composition and entry orbit, the thermal environment of Mars entry vehicles is very different from that of Earth space vehicles. The entry process involves a non-air high-speed flow, leading to serious aerothermal heating problems. The arc-heated wind tunnels are used to simulate the aerothermal heating environment for Mars entry, which is a key step in validating the thermal protection system design for Mars exploration. The -high-temperature flow simulated by the arc-heated wind tunnel includes a dominated CO2 dissociation reaction, and dissociation species such as CO interact with the thermal materials of the Mars entry vehicles, which would cause a catalytic effect and significantly affect the aerothermal environment. In this paper, the mid-infrared quantum cascade laser absorption spectroscopy is carried out for in-situ and quantitative measurements of the flow characteristics of ground-based simulation for Mars entry in the arc-heated facility. The in-situ diagnosis in the arc-heated facility utilizes the spectral line of CO with a central wavelength of 2 212.625 cm-1 (ν″=0, R(19)) near 4.5 μm, to achieve a high signal-to-noise ratio measurement of the ground-based flow field. A single-line direct absorption spectroscopy obtains the static temperature and CO mole fraction of free stream in the arc-heated wind tunnel. Under a typical condition for Mar entry, the static temperature and CO mole fraction of freestream remain stable throughout the operation, showing good stability in the arc-heated flow field. Six repeated experiments show that the static temperature and CO mole fraction are in the range of (1 757±69) K and (0.189±0.027) respectively, with fluctuation of less than or equal to 3.9% in flow temperature and fluctuation of less than or equal to 14.3% in CO concentration, demonstrating great repeatability for the ground-based simulated flow field. The developed mid-infrared laser absorption spectroscopy diagnostic technology in the arc-heated wind tunnel can provide refined measurement capabilities for research of the aerothermal environment and ablation-catalytic properties of the thermal protection materials of the Mars entry vehicles.
|
Received: 2022-02-18
Accepted: 2023-11-21
|
|
|
[1] OUYANG Zi-yuan, XIAO Fu-gen(欧阳自远, 肖福根). Spacecraft Environment Engineering(航天器环境工程), 2011, 28(3): 205.
[2] OUYANG Zi-yuan, XIAO Fu-gen(欧阳自远, 肖福根). Spacecraft Environment Engineering(航天器环境工程), 2012, 29(6): 591.
[3] YU Deng-yun, SUN Ze-zhou, MENG Lin-zhi, et al(于登云, 孙泽洲, 孟林智, 等). Journal of Deep Space Exploration(深空探测学报), 2016,3(2): 108.
[4] GENG Yan, ZHOU Ji-shi, LI Sha, et al(耿 言, 周继时, 李 莎, 等). Journal of Deep Space Exploration(深空探测学报), 2018, 5(5): 399.
[5] TANG Wei, YANG Xiao-feng, GUI Ye-wei, et al(唐 伟, 杨肖峰, 桂业伟, 等). Journal of Astronautics(宇航学报), 2017, 38(3): 230.
[6] Wang X, Yan C, Zheng W, et al. Acta Astronautica, 2016, 128: 217.
[7] Bugel M, Reynier P, Smith A. International Journal of Aerospace Engineering, 2011, 2011: 1.
[8] Hermann T, Löhle S, Zander F, et al. Journal of Quantitative Spectroscopy and Radiative Transfer, 2017, 201: 216.
[9] Liu C, Xu L. Applied Spectroscopy Reviews, 2019, 54(1): 1.
[10] Meyers J M, Fletcher D. Journal of Thermophysics and Heat Transfer, 2011, 25(2): 193.
[11] Pannier E, Laux C O. Journal of Thermophysics and Heat Transfer, 2019, 33(4): 1127.
[12] Jelloian C C, Bendana F A, Wei C, et al. Journal of Thermophysics and Heat Transfer, 2022, 36(2): 266.
[13] Welzel S, Hempel F, Hübner M, et al. Sensors, 2010, 10(7): 6861.
[14] Gordon I E, Rothman L S, Hargreaves R J, et al. Journal of Quantitative Spectroscopy and Radiative Transfer, 2022, 277: 107949.
|
[1] |
LIU Han-yang1, XING Cheng-zhi3*, JI Xiang-guang4, LIN Ji-nan3, ZHAO Chun-hui3, WEI Shao-cong2, ZHANG Cheng-xin2, LIU Hao-ran5, TAN Wei3, LIU Cheng2. Taking Juehua Island as a Typical Example to Explore the Vertical
Distribution Characteristics and Potential Sources of Air Pollutants[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 760-766. |
[2] |
ZHANG Le-wen1, 2, WANG Qian-jin1, 3, SUN Peng-shuai1, PANG Tao1, WU Bian1, XIA Hua1, ZHANG Zhi-rong1, 3, 4, 5*. Analysis of Interference Factors and Study of Temperature Correction Method in Gas Detection by Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 767-773. |
[3] |
HONG Guang-lie1, LIANG Xin-dong1, 2, LIU Hao1*, ZHANG Hua-ping1, 2, SHU Rong1, 2. Detection of CO2 Average Concentration in Atmospheric Path by CW Modulated Differential Absorption Lidar[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3653-3658. |
[4] |
WAN Liu-jie1, 2, ZHEN Chao3, QIU Zong-jia1, LI Kang1, MA Feng-xiang3, HAN Dong1, 2, ZHANG Guo-qiang1, 2*. Research of High Precision Photoacoustic Second Harmonic Detection Technology Based on FFT Filter[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 2996-3001. |
[5] |
ZHANG Yan1, 2, ZHOU Shi-sheng2*, CAO Cong-jun2, REN Peng-gang2. An Absorbance-Based Prediction Method of Spot Color Formula for PET Film[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(02): 415-420. |
[6] |
ZHOU Sheng1, 2, HAN Yan-ling1, LI Bin-cheng1, 3*. Calibration Method of Pressure Gauges Based on Cavity Ring-Down Spectroscopy Technique[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(04): 1031-1035. |
[7] |
XIAN Lei-yong1, LI You-liang1, HE Jiu-ning1, ZHANG Chang-hua1*, LI Ping1, LI Xiang-yuan2 . Measurement of Soot Yield from the Pyrolysis of Toluene at High Temperatures by Laser Extinction Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(11): 3481-3484. |
[8] |
LI Zhi1, 2, LIAN Fei-yu1, 2. Research on Scattering in the THz Quantitative Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(06): 1666-1669. |
[9] |
ZHANG Tian-yao1,2, ZHANG Zhao-hui1,2*, ZHAO Xiao-yan1,2, ZHANG Han1,2, YAN Fang1,2, QIAN Ping3 . Terahertz Absorption Spectra Simulation of Glutamine Based on Quantum-Chemical Calculation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(08): 2073-2077. |
[10] |
WEI Wei1, 2, ZHU Yong2, LIN Cheng2, TIAN Li2, XU Zu-wen2, NONG Jin-peng2 . Study on the Absorption Spectrum Properties of Flexible Black Silicon Doped with Sulfur and Fluorine Based on First-Principles [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(04): 910-914. |
[11] |
SU Hai-xia, ZHANG Zhao-hui, ZHAO Xiao-yan*, LI Zhi, YAN Fang, ZHANG Han . The Lambert-Beer’s Law Characterization of Formal Analysis in Terahertz Spectrum Quantitative Testing[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(12): 3180-3186. |
[12] |
WU Bin1, 2, SHI Xue-shun1, 2, SUN Qing3, DENG Yu-qiang3, WANG Heng-fei2, CHEN Kun-feng2 . Frequency Correction in Terahertz Absorption Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(09): 2343-2347. |
[13] |
SU Hai-xia, ZHANG Zhao-hui*, ZHAO Xiao-yan, LI Zhi, YAN Fang, ZHANG Han . Intrinsic Section and Its Interception Model for Temporal Pulse of THz-TDS [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(04): 921-925. |
[14] |
WANG Yang, XIE Pin-hua*, LI Ang, XU Jin, ZENG Yi, SI Fu-qi, WU Feng-cheng . Retrieval of NO2 Total Vertical Columns by Direct-Sun Differential Optical Absorption Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(04): 893-897. |
[15] |
LI Zhi, ZHANG Zhao-hui*, ZHAO Xiao-yan, SU Hai-xia, YAN Fang. Extracting THz Absorption Coefficient Spectrum Based on Accurate Determination of Sample Thickness[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(04): 1043-1046. |
|
|
|
|