Neural Network Filtering Method for Carbon Dioxide Gas Detection in TDLAS |
ZHAO Yu-ying1, WANG Le2, HUANG Tian-he1, SONG Yu-xiao3, BI Wen-hao1, LI Wen-xuan1, JIANG Chen-yu1, 4* |
1. School of Medical Information Engineering, Shandong University of Traditional Chinese Medicine, Jinan 250355, China
2. Physical Education Department, Shandong University of Traditional Chinese Medicine, Jinan 250355, China
3. Jinan Guoke Medical Technology Development Co., Ltd., Jinan 250001, China
4. Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
|
|
|
Abstract Carbon dioxide (CO2) gas detection has important research significance in various fields, such as environmental monitoring, agricultural production, and microbial detection. Tunable diode laser absorption spectroscopy(TDLAS/WMS) based on wavelength modulation detection systems has become an important means of precision gas detection due to its significant advantages of high sensitivity, low cost, non-invasiveness, and real-time monitoring. However, the system is susceptible to interference from various environmental noises, significantly impacting gas detection accuracy and stability. The commonly used traditional time-frequency analysis algorithm cannot effectively filter out the low-frequency signal noise coupled with the absorption signal, which will interfere with the subsequent gas concentration retrieval task. With their powerful feature mapping capabilities, deep learning algorithms can project signals into a new feature space, learn the distribution of spectral signal background structures, and thus overcome the limitations of time-frequency domain filtering algorithms. Therefore, a deep learning-based TDLAS carbon dioxide gas detection filtering algorithm (TGDF) is proposed to reduce the influence of full-frequency noise in the gas detection system and improve the accuracy of gas measurements. The TGDF takes a fully connected neural network as the infrastructure and adds sampling blocks to remove noise in the feature domain; in addition, the singular value decomposition is introduced to further adjust the harmonic signals. The model is trained, tested, and tuned by simulating different concentrations of CO2 absorption spectra with noise under experimental conditions, and the model performance is tested on the experimental dataset. In the simulation experiments, the average signal-to-noise ratio of the TGDF-filtered spectra increased by a factor of 3.05 from 7.34 dB to 22.41 dB. It kept the lowest noise residuals in the frequency domain. In real experiments, there is a good linear relationship between the second harmonic amplitude and preset concentrations of CO2 (R2=0.998); the average absolute error (MAE) of five CO2 detections is divided into 0.27%, 0.20%, 0.23%, 0.28% and 0.32%. Compared with the commonly used filtering algorithms such as EMD, SG, Wavelet transform, and MLP neural networks in these two datasets, the TGDF showed the best performance in suppressing systematic noises of different frequencies and phases. The results fully proved that TGDF could effectively reduce the systematic noise of each frequency band in the harmonic signal of gas detection and improve the accuracy and stability of TDLAS CO2 concentration detection, which provides a feasible technical means for high-sensitivity measurement of CO2 and other trace gases.
|
Received: 2024-08-09
Accepted: 2024-12-10
|
|
Corresponding Authors:
JIANG Chen-yu
E-mail: jiangcy@sibet.ac.cn
|
|
[1] DAI Tong-xin, WANG Biao, LIAN Hou-quan, et al(戴童欣, 王 彪, 连厚泉, 等). Laser Journal(激光杂志), 2021, 42(4): 41.
[2] JIN Jiang-tie, LI Yang, LI Rong-jun, et al(金奖铁, 李 扬, 李荣俊, 等). Plant Physiology Journal(植物生理学报), 2019, 55(5): 558.
[3] Fodor N, Challinor A, Droutsas I, et al. Plant and Cell Physiology, 2017, 58(11): 1833.
[4] Shao Jie, Xiang Jindong, Axner O, et al. Applied Optics, 2016, 55(9): 2339.
[5] Sun Jing, Song Yuxiao, Shi Dongxin, et al. Processes, 2022, 10(8): 1450.
[6] Fu Bo, Zhang Chenghong, Lü Wenhao, et al. Applied Spectroscopy Reviews, 2022, 57(2): 112.
[7] LI Jin-yi, LI Lian-hui, ZHAO Shuo, et al(李金义,李连辉, 赵 烁, 等). Laser & Optoelectronics Progress(激光与光电子学进展), 2022, 59(13): 65.
[8] LIU Zhao-hai, AN Xin-chen, TAO Zhi, et al(刘兆海, 安昕辰, 陶 治, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2024, 44(2): 359.
[9] Lins B, Zinn P, Engelbrecht R, et al. Applied Physics B: Lasers and Optics, 2010, 100(2): 367.
[10] Li Jingsong, Yu Benli, Zhao Weixiong, et al. Applied Spectroscopy Reviews, 2014, 49(8): 666.
[11] TIAN Chuan, ZOU Li-chang, RUAN Bin, et al(田 川,邹丽昌,阮 斌,等). Chinese Journal of Quantum Electronics(量子电子学报), 2021, 38(5): 661.
[12] Zhang Guosheng, Hao He, Wang Yichen, et al. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2021, 263: 120187.
[13] FENG Shi-ling, CUI Qi, GUO Xin-qian, et al(冯仕凌,崔 琪,郭心骞,等). Journal of Atmospheric and Environmental Optics(大气与环境光学学报), 2022, 17(3): 328.
[14] Li Chuanliang, Guo Xinqian, Ji Wenhai, et al. Optical and Quantum Electronics, 2018, 50: 275.
[15] Zhang Tianyu, Kang Jiawen, Meng Dezhuang, et al. Sensors, 2018, 18(12): 4295.
[16] Sun Jiachen, Chang Jun, Wei Yubin, et al. Analytical Chemistry, 2022, 94(41): 14290.
[17] Wang Senyuan, Yang Shicheng, Zhu Shouzheng, et al. Optics Express, 2024, 32(7): 11849.
[18] Luo Qiwu, Zhou Jian, Li Weichuang, et al. IEEE Sensors Journal, 2022, 22(3): 2419.
[19] Zhao Peng, Ding Dan, Li Kaitai, et al. Optics Communications, 2024, 567: 130327.
|
[1] |
HUANG Wen-biao1, 2, XIA Hua2*, WANG Qian-jin1, 2, SUN Peng-shuai2, PANG Tao2, WU Bian2, ZHANG Zhi-rong1, 2, 3, 4*. Research on Measurement Method of δ 13C and δ 18O Isotopes Abundance in Exhaled Gas Based on the BP Neural Network Model[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(10): 2761-2767. |
[2] |
FANG Xiao-meng, WANG Hua-lai, XU Hui, HUANG Meng-qiang, LIU Xiang*. Identification and Detection of Multi-Component Trace Gases Based on Near-Infrared TDLAS Technology Based on SVM[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(10): 2909-2915. |
[3] |
LIANG Wen-ke, WEI Guang-fen, WANG Ming-hao. Research on Methane Detection Error Caused by Lorentzian Profile Approximation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1683-1689. |
[4] |
DU Bao-lu, LI Meng, GUO Jin-jia*, ZHANG Zhi-hao, YE Wang-quan, ZHENG Rong-er. The Experimental Research on In-Situ Detection for Dissolved CO2 in
Seawater Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1264-1269. |
[5] |
MA Li1, 2, FAN Xin-li1, 2, ZHANG Shuo1, 2, WANG Wei-feng1, 2, WEI Gao-ming1, 2. Research on CH4 Gas Detection and Temperature Correction Based on TDLAS Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(11): 3632-3638. |
[6] |
WANG Guo-shui1, GUO Ao2, LIU Xiao-nan1, FENG Lei1, CHANG Peng-hao1, ZHANG Li-ming1, LIU Long1, YANG Xiao-tao1*. Simulation and Influencing Factors Analysis of Gas Detection System Based on TDLAS Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3262-3268. |
[7] |
LU Yi-bing1, 2, LIU Wen-qing1, 2, ZHANG Yu-jun1, 2*, ZHANG Kai1, 2, HE Ying1, 2, YOU Kun1, 2, LI Xiao-yi1, LIU Guo-hua1, 2, TANG Qi-xing1, 2, FAN Bo-qiang1, 2, YU Dong-qi1, 2, LI Meng-qi1, 2. An Adaptive Hierarchical Savitzky-Golay Spectral Filtering Algorithm and Its Application[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(09): 2657-2663. |
[8] |
ZHU Gao-feng1, 2, HU Xin1, ZHU Hong-qiu1*, HU En-ze1, ZHU Jian-ping3. The Multi-Beam Interference Suppression for Measuring Penicillin Vial’s Oxygen Concentration Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(02): 372-376. |
[9] |
LI Chuan-liang1*, JIANG Li-jun1, SHAO Li-gang1, GUO Xin-qian1, QIU Xuan-bing1, WEI Ji-lin1, GAO Rui1, WANG Gao2. The Detection of CO Based on TDLAS Combined with Balanced Difference Detection Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3165-3169. |
[10] |
NIE Wei1, 2, YE Qing-hao3, XU Zhen-yu1, ZHANG Guang-le1, XIA Hui-hui1, 2, KAN Rui-feng1* . Study on the Method of Voigt Profiles Two Wings Fitting Non-Uniform Flow Field Absorbance [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(03): 816-821. |
[11] |
CHEN Jiu-ying1, LIU Jian-guo1*, HE Jun-feng2, HE Ya-bai1, ZHANG Guang-le1, XU Zhen-yu1, GANG Qiang3, WANG Liao3, YAO Lu1, YUAN Song1, RUAN Jun1, DAI Yun-hai1, KAN Rui-feng1 . Study of High Temperature Water Vapor Concentration Measurement Method Based on Absorption Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(12): 3174-3177. |
[12] |
SONG Jun-ling, HONG Yan-ji, WANG Guang-yu, PAN Hu . Measurement of Nonuniform Temperature and Concentration Distribution by Absorption Spectroscopy Based on Least-Square Fitting [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(08): 2047-2050. |
[13] |
LOU Nan-zheng, LI Ning*, WENG Chun-sheng. In Situ Temperature Measurement by Absorption Spectroscopy Based on Time Division Multiplexing Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(05): 1329-1333. |
[14] |
TIAN Yong-zhi1,2, LIU Jian-guo1*, ZHANG Yu-jun1, LU Yi-huai1, HE Ying1 . On Using Tunable Diode Laser Absorption Spectroscopy to Determine Gas Fluxes over Cropland [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(04): 1072-1076. |
[15] |
GAO Wei1, 2, CAO Zhen-song1, 2, YUAN Yi-qian1, 2, GAO Xiao-ming1, 2* . Design of a Controllable Low Temperature Cell and Application[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(03): 858-861. |
|
|
|
|