Study on Extraction Method of Terahertz Spectral Parameters of Rough Surface Samples |
YU Yang1, ZHANG Zhao-hui1, 2*, ZHAO Xiao-yan1, ZHANG Tian-yao1 |
1. School of Automation and Electrical Engineering, University of Science and Technology Beijing, Beijing 100083, China
2. Beijing Engineering Research Center of Industrial Spectrum Imaging, Beijing 100083, China
|
|
|
Abstract The spectral parameters of many substances within the terahertz band have fingerprint characteristics, which is the basis of the application of the terahertz technology in many fields such as security inspection. However, it is required that the upper and lower surfaces of samples should be parallel and smooth for the Duvillaret algorithm, which is commonly used to extract the optical parameters of materials in terahertz time-domain spectroscopy (THz-TDS). Moreover, surface roughness is inevitable, and laboratory sample preparation methods such as mold pressing can not be utilized to ensure the parallelism and smoothness of the surface in many potential practical applications, especially for solid samples. Therefore, a universal optical parameter extraction algorithm that is not easily affected by the surface roughness of samples is needed to increase the application ability of THz-TDS in different situations. In this paper, the optical path of the transmission of the terahertz wave through rough samples is analyzed, and a terahertz transmission model of rough samples, including roughness, refractive index and extinction coefficient parameters, is established. Under the condition of known roughness and average thickness, the applicability of the transmission model is verified by extracting the refractive index and absorption coefficient of rough samples with characteristic absorption peaks in the terahertz band. -----The α-Lactose and L-Histidine which have typical absorption features at terahertz frequencies are selected as experimental material. Pellets at the same concentration are prepared and further separated into the rough surface group and smooth surface group. The refractive index, as well as absorption coefficient, are calculated with both our proposed model and conventional Duvillaret algorithm. The comparison between the results is further analyzed for evaluating our method,the root-mean-square error (RMSE) between the two extraction methods and the standard value is calculated, and the extraction results of the transmission model, the Duvillaret algorithm and the standard value extracted from the parallel and smooth sample are compared at the same time. The comparison results show that, compared with the Duvilaret algorithm, the refractive index and absorption coefficient of the rough sample extracted by the transmission model method has smaller deviations from the standard value, which reduces the influence of roughness on the extraction result to a certain extent and has higher accuracy. Therefore, under the condition of known roughness and average thickness of the surface rough sample, this model can be used to more accurately extract the optical parameters of the substance in the terahertz time-domain spectroscopy system. The research results will greatly promote the practical application of terahertz optical parameter extraction technology.
|
Received: 2021-02-01
Accepted: 2021-05-05
|
|
Corresponding Authors:
ZHANG Zhao-hui
E-mail: zhangzhaohui@ustb.edu.cn
|
|
[1] Zhang T, Zhang Z, Arnold M A. Applied Spectroscopy, 2019, 73(3): 253.
[2] Liebermeister L, Nellen S, Kohlhaas R, et al. Journal of Infrared, Millimeter, and Terahertz Waves, 2019, 40(3): 288.
[3] Kong D Y, Wu X J, Wang B, et al. Optics Express, 2018, 26(14): 17964.
[4] Peretti R, Mitryukovskiy S, Froberger K, et al. IEEE Transactions on Terahertz Science and Technology, 2019, 9(2): 136.
[5] Mumtaz M, Mahmood M A, Shahzad A, et al. Journal of Infrared, Millimeter, and Terahertz Waves, 2020, 41(10): 1181.
[6] Bernier M, Garet F, Kato E, et al. Journal of Infrared, Millimeter, and Terahertz Waves, 2018, 39(4): 349.
[7] Zhang H, Zhang Z, Zhao X, et al. Chinese Optics Letters, 2018, 16(10): 103001.
[8] ZHANG Tian-yao, ZHANG Zhao-hui, et al(张天尧,张朝晖,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2019, 39(6): 1689.
[9] Yi W, Yu J, Xu Y, et al. Instrumentation Science & Technology, 2017, 45(4): 423.
[10] Duvillaret L, Garet F, Coutaz J L. IEEE Journal of Selected Topics in Quantum Electronics, 1996, 2(3): 739.
[11] Yu Y, Zhang Z, Zhang T, et al. Optical and Quantum Electronics, 2020, 52(5): 240.
[12] Zhang T, Zhang Z, Zhao X, et al. Applied Optics, 2020, 59(16): 4775.
[13] Withayachumnankul W, Naftaly M. Journal of Infrared, Millimeter, and Terahertz Waves, 2014, 35(8): 610.
[14] Komandin G A, Gavdush A A, Goncharov Y G, et al. Optics and Spectroscopy, 2019, 126(5): 514.
[15] Zong S, Ren G H, Li S, et al. Journal of Molecular Structure, 2018, 1157: 486.
|
[1] |
YU Yang1, ZHANG Zhao-hui1, 2*, ZHAO Xiao-yan1, ZHANG Tian-yao1, LI Ying1, LI Xing-yue1, WU Xian-hao1. Effects of Concave Surface Morphology on the Terahertz Transmission Spectra[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2843-2848. |
[2] |
SHI Dong-dong, CAO Zhao-bin, HUAN Yan-hua, GONG Yan-chun, WU Wen-yuan, YANG Jun*. Reflection Polarization Spectral Characteristics of High Performance Coating Material La2Zr2O7[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(10): 2995-2999. |
[3] |
XU Lu1, CHEN Yi-yun1, 2, 3*, HONG Yong-sheng1, WEI Yu1, GUO Long4, Marc Linderman5. Estimation of Soil Organic Carbon Content by Imaging Spectroscopy With Soil Roughness[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(09): 2788-2794. |
[4] |
XU Ji-kun1, LI Tian-zi1, 2*, REN Yu-juan1. Experimental Study on the Effect of Roughness on the Inversion of SiO2 Content in Iron Ore by the Thermal Infrared Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(07): 2153-2158. |
[5] |
CHEN Ping1, WANG Xi-lin1, HONG Xiao2, WANG Han3, ZHAO Chen-long1, JIA Zhi-dong1, ZOU Lin2, LI Yan-min4, FAN Jian-hua4. Influence of Sample Surface Roughness on Signal of Laser-Induced Breakdown Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(06): 1929-1934. |
[6] |
LI Chen-xi1,2, JIANG Jing-ying2, LIU Rong1,2, CHEN Wen-liang1, 2*, XU Ke-xin1,2. Research on the Influence of Pressure-Induced Skin Deformation on the Diffuse Reflectance Spectra Measurement[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3006-3010. |
[7] |
LI Tian-zi2, 3,LIU Shan-jun1, 2*. A Study on the Effects of Roughness on Thermal Infrared Spectral Unmixing of Rock[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3051-3057. |
[8] |
HU Wen-yan1,3, WANG Yu-heng1,3, ZHANG Xiao-shuan2, LI Jun-hui1,3, WANG Zhong-yi1,3, ZHAO Long-lian1,3*. Determination and 3D Reconstruction of Optical Parameters of Biological Tissue Based on Frequency-Domain Near-Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(05): 1374-1379. |
[9] |
LIU Yong1,2, ZHANG Yuan-zhi1, HOU Hua-yi1, ZHU Ling1,2, WANG An1, WANG Yi-kun1,2*. Tissue Intrinsic Fluorescence Spectrum Recovering Based on Diffusion Theory[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(12): 3836-3841. |
[10] |
LIU En-chao, LI Xin, WEI Wei, ZHAI Wen-chao, ZHANG Yan-na, ZHENG Xiao-bing . Automatic Field Calibration and Analysis of Satellite Based on Hyper-Spectral Ratio Radiometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(12): 4076-4081. |
[11] |
HAN Xiao-hui, ZHANG Jin*, YANG Ye, MA Yu-ting, CHANG Tian-ying, CUI Hong-liang . Review on the Methodology for Optical Parameter Extraction with Terahertz Time-Domain Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(11): 3449-3454. |
[12] |
SUN Yao, WANG Hong . Analysis of Glass Surface Modification with Ion Beam Based on Ellipsometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(10): 3388-3393. |
[13] |
LI Chen-xi1, 2, SUN Zhe2, HAN Lei2, ZHAO Hui-juan1, 2*, XU Ke-xin1, 2. Study on the Determination System of Tissue Optical Properties Based on Diffuse Reflectance Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1532-1536. |
[14] |
HAN Lei1, LI Chen-xi1, 2*, SUN Cheng-tao1, JIANG Jing-ying1, ZHAO Hui-juan1,2, XU Ke-xin1,2 . The Research on Measurement System and Method of Tissue Optical Parameters with Wide Spectra Based on Double-Integrating-Spheres[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(02): 561-566. |
[15] |
LING Jin-jiang, LI Gang, ZHANG Ren-bin, TANG Qian, YE Qiu . Modeling and Simulation of Spectral Polarimetric BRDF [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(01): 42-46. |
|
|
|
|