Laboratory Calibration and Temperature Research of Spectral Radiometric Instruments |
LI Ling, DAI Cai-hong, WU Zhi-feng, WANG Yan-fei |
Division of Optics, National Institute of Metrology, China, Beijing 100029, China |
|
|
Abstract The uncertainty of laboratory calibrated spectroradiometers used in field was analyzed. Ambient temperature is one of the most important factors limiting the accuracy of outdoor measurements. Currently, the laboratory calibrations are generally performed at room temperature [(25±1.0) ℃]. However, the spectrometers applied in earth observation and remote sensing is usually operated in the field under different ambient temperature conditions. The calibration coefficients determined under room temperature are not applicable to data collected in field conditions. In this paper, the experimental measurement system was set up, which was used to investigate the temperature effects. The sensitivity of spectroradiometers (CR-280) at different wavelengths was affected differently by ambient temperature. The deviation of 400~700 nm between measured and calibrated value at 40° is about ±5%. The deviation of near-infrared wavelengths (1 050 nm) is about ±15%, this spectral range is close to the band edge of the silicon, which is highly temperature sensitive, and the silicon band edge moved to longer wavelengths as increasing temperature. It is important to reduce the deviation of measured results in field after laboratory calibration. Here, a temperature correction method by matrix calculation for different kinds of spectroradiometers was proposed, which calculated the spectroradiometer response at each pixel. The correction method was also verified with a randomly selected temperature. It can reduce the deviation of CR-280 from ±10% to ±1% in the near-infrared wavelengths (about 950 nm). The temperature correction method can be easily used for spectral radiometry measurement in the field, which can be greatly improves the accuracy of spectral radiometry measurement. Also, the other two kinds of spectroradiometers (Avantes, SVC H-1024) were used to verify this correction method. The result showed the deviation of Avantes (VIS/NIR) between measured and calibrated value (about 1 060 nm) is reduced from ±17% to ±1%. At different ambient temperatures, the deviations between the measured and calibrated values of SVC HR-1024 are different. The instrument consists of three detectors: Si, cooled InGaAs and extended InGaAs. Si detector is greatly affected by temperature, and the deviation of the measured and calibrated value (950~1 000 nm) is as high as ±10%. The cooled InGaAs can effectively control the detector temperature. However, as the ambient temperature increases, the InGaAs detector is affected (the optimal working environment for cooling is about 20 ℃), and the deviation of measuredand calibrated value results is 1%~3%. The temperature correction formulas were used to correct the measured results. The deviation of SVC HR-1024 can be reduced to ±1%.
|
Received: 2018-05-06
Accepted: 2018-11-20
|
|
|
[1] Kato S, Rose F G, Sun Mack S, et al. Journal of Geophysical Research, 2011, 116: D19209.
[2] Laurent V C E, Schaepman M E, Verhoef W, et al. Remote Sensing of Environment, 2014, 140: 318.
[3] Laurent V C E, Verhoef W, Clevers J G P W, et al. Remote Sensing of Environment, 2011, 115(4): 1043.
[4] Pigeot-Rémy S, Simonet F, Atlan D, et al. Water Research, 2012, 46(10): 3208.
[5] Kuusk J. Journal of Sensors, 2011, 2011: 608157.
[6] Wang H, Song H, Chen Y, et al. Applied Optics, 2015, 54: 3162.
[7] Starks P J, Walter-Shea E A, Schiebe F R, et al. Remote Sensing of Environment, 1995, 51: 385.
[8] Widenhorn R, Blouke M M, Weber A, et al. Proceedings of SPIE, 2002, 4669: 193.
[9] Wang H, Chen Y, Song H, et al. Journal of Atmospheric and Oceanic Technology, 2014, 31: 2844.
[10] Salim S G R, Fox N P, Theocharous E, et al. Applied Optics, 2011, 50: 866. |
[1] |
ZHANG Ning-chao1, YE Xin1, LI Duo1, XIE Meng-qi1, WANG Peng1, LIU Fu-sheng2, CHAO Hong-xiao3*. Application of Combinatorial Optimization in Shock Temperature
Inversion[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3666-3673. |
[2] |
LIANG Ya-quan1, PENG Wu-di1, LIU Qi1, LIU Qiang2, CHEN Li1, CHEN Zhi-li1*. Analysis of Acetonitrile Pool Fire Combustion Field and Quantitative
Inversion Study of Its Characteristic Product Concentrations[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3690-3699. |
[3] |
LI Xiao-dian1, TANG Nian1, ZHANG Man-jun1, SUN Dong-wei1, HE Shu-kai2, WANG Xian-zhong2, 3, ZENG Xiao-zhe2*, WANG Xing-hui2, LIU Xi-ya2. Infrared Spectral Characteristics and Mixing Ratio Detection Method of a New Environmentally Friendly Insulating Gas C5-PFK[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3794-3801. |
[4] |
CHEN Heng-jie, FANG Wang, ZHANG Jia-wei. Accurate Semi-Empirical Potential Energy Function, Ro-Vibrational Spectrum and the Effect of Temperature and Pressure for 12C16O[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3380-3388. |
[5] |
YU Hao-zhang, WANG Fei-fan, ZHAO Jian-xun, WANG Sui-kai, HE Shou-jie*, LI Qing. Optical Characteristics of Trichel Pulse Discharge With Needle Plate
Electrode[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(10): 3041-3046. |
[6] |
TIAN Fu-chao1, CHEN Lei2*, PEI Huan2, BAI Jie-qi1, ZENG Wen2. Diagnosis of Emission Spectroscopy of Helium, Methane and Air Plasma Jets at Atmospheric Pressure[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2694-2698. |
[7] |
ZENG Si-xian1, REN Xin1, HE Hao-xuan1, NIE Wei1, 2*. Influence Analysis of Spectral Line-Shape Models on Spectral Diagnoses Under High-Temperature Conditions[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2715-2721. |
[8] |
LI Chang-ming1, CHEN An-min2*, GAO Xun3*, JIN Ming-xing2. Spatially Resolved Laser-Induced Plasma Spectroscopy Under Different Sample Temperatures[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(07): 2032-2036. |
[9] |
LIANG Wen-ke, WEI Guang-fen, WANG Ming-hao. Research on Methane Detection Error Caused by Lorentzian Profile Approximation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1683-1689. |
[10] |
WANG Pei-qi, CHENG Xiao-fang*, ZHANG De-bin. Radiation Thermometry Method Based on Intersection Capture of Spectral Distribution Curves[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1676-1682. |
[11] |
LIU Si-ran1, GONG Xin1, YAN Bi-chen2. Determining the Firing Temperature of Ancient Ceramics With FTIR Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1495-1500. |
[12] |
ZHANG Li-fang1, YANG Yan-xia1, ZHAO Guan-jia1, MA Su-xia1, GUO Xue-mao2. Comparison of Numerical Iterative Algorithms for Two-Dimensional Absorption Spectral Reconstruction[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1367-1375. |
[13] |
LIU Rong1, 2, WANG Miao-miao1, 2 , SUN Ze-yu1, 2, CHEN Wen-liang1, 2, LI Chen-xi2*, XU Ke-xin1, 2. Research on Temperature Disturbance of Glucose Solution With
Two-Trace Two-Dimensional Correlation Spectrum Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1051-1055. |
[14] |
CHEN Feng-yi, ZHANG Yu-gui*, WANG Wei-gang, XU Peng-mei. Research on Asteroid Surface Temperature Inversion Method Based on Wide Wavelength Band Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1162-1167. |
[15] |
OUYANG Ke-chen1, 2, XING Li2, WANG Zheng2, 3, FENG Xiao-juan2*, ZHANG Jin-tao2, REN Cheng1, YANG Xing-tuan1. Analysis and Suppression of Laser-Induced Error in Temperature
Measurement Based on Nitrogen-Vacancy Centers in Diamond[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1242-1247. |
|
|
|
|