Application of Multi-Channel Differential Optical Density on the Fast Determination of the Intracranial Hematomas Degree |
WANG Jin-hai1, LIU Dong-yuan1, 2, WANG Hui-quan1*, ZHANG Yan-jun2, SUN Qiu-ming2, MA Jun2 |
1. School of Electronics and Information Engineering, Tianjin Polytechnic University, Tianjin 300387, China
2. Institute of Medical Equipment, Academy of Military Medical Sciences, Tianjin 300161, China |
|
|
Abstract Differential near infrared optical density has the advantages of rapid and noninvasive detection when detecting the traumatic subdural hematoma . This technology is a hot research topic in recent years, it has an important application in emergency treatment. To further improve the accuracy of traumatic subdural hematoma degree predication, the multi-channel differential absorbance method is used in this paper. We use 5 detectors that have different distance to the source to obtain absorbance data. In addition, we use partial least square method to establish the calibration model between the optical absorption coefficient of the brain and differential optical density. The model prediction results show that average relative error of absorption coefficient is 11.16%, and average relative error of hematoma depth is less than 1%. The model basically meets the demand of traumatic subdural hematoma degree predication. By introducing multi-channel differential optical density in the detection, it could eliminate the effects of individual differences and improve the accuracy of traumatic subdural hematoma degree predication. This method provides a new idea and an important reference for the brain detection with near infrared spectroscopy.
|
Received: 2016-08-31
Accepted: 2017-02-13
|
|
Corresponding Authors:
WANG Hui-quan
E-mail: huiquan@tjpu.edu.cn
|
|
[1] Tushar Kanti Bera. Intelligent Systems Reference Library, 2015, 74: 51.
[2] XU Gang, LI Xiao-li, LIU Xiao-min(徐 刚,李小俚,刘晓民). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2015,35(2): 552.
[3] Nourhashemi M,Mahmoudzadeh M, Wallois F. Neurophotonics, 2016, 3(1):015001.
[4] Uthaman S,Bom J S, Kim H S, et al. Journal of Biomedical Materials Research Part B Applied Biomaterials, 2016, 104(4): 825.
[5] Kato S, Yoshitani K, Ohnishi Y. Journal of Neurosurgical Anesthesiology, 2016, 28(4): 291.
[6] Braun T, Kunz U, Schulz C, et al. Unfallchirurg, 2014, 1: 1.
[7] Robertson C S,Gopinath S P, Chance B. Biomed. Opt., 1997, 2: 31.
[8] Salonia R, Bell M J, Kochanek P M, et al. Journal of Neurotrauma,2012, 29(3): 1047.
[9] Bartomiej Tyzo, Tomasz Trojanowski, Dariusz Sztzepanki, et al. Neurologia Praktyczna, 2014, 2: 13.
[10] WANG Xue-na, LI Wei-tao, QIAN Zhi-yu, et al(王雪娜, 李韪韬, 钱志余, 等). Acta Photonica Sinica(光子学报),2011,40(2):277.
[11] Li X M, Wei W H, Fan Y F, et al. Journal of Medical Imaging and Health Informatics, 2016, 6(7): 1741.
[12] Adkins C E, Mohammad A S, Terrellhall T B, et al. Clinical & Experimental Metastasis, 2016, 33(4): 373.
[13] Strangman Gary E, Zhang Quan, Li Zhi. NeuroImage, 2014, (85): 136.
[14] Hsieh C T, Su I C, Hsu S K, et al. Journal of Clinical Neuroscience, 2016, 34: 252.
[15] Wang L H, Jacques S L, et al. Computer Methods and Programs in Biomedicine, 1995, 47: 131. |
[1] |
ZHAO Zhe1, 2, 3, WANG Hui1, WANG Hui-quan1, 2, 3*, HE Xin-wei1, MIAO Jing-hong1, 2, WANG Jin-hai1, 2*. Influence of Spectral Characteristics on the Accuracy of Concentration Quantitatively Analysis by NIR[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(04): 1070-1074. |
[2] |
ZHANG Yan-jun1, SUN Qiu-ming1, WANG Hui-quan2, ZHAO Zhe2, SUN Jing-gong1, MA Jun1*, LIU Dong-yuan1, 2. VIP Analysis to Simplify the NIR Detection Study of the Dural Hematoma[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(06): 1691-1695. |
[3] |
MOU Fu-sheng1,2, LI Ang1, XIE Pin-hua1,3,4, WANG Yang5, ZHANG Jie1, XU Jin1, WU Feng-cheng1, CHEN Hao1. Study of Tropospheric NO2 VCD from August 2013 to July 2014 with Ground-Based MAX-DOAS in Hefei and Comparison with OMI Observation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(04): 1042-1047. |
[4] |
JIANG Yan-xiu1, 2, Bayanheshig1*, YANG Shuo1, 2, ZHAO Xu-long1, 2, WU Na1, LI Wen-hao1 . Study on the Effects and Compensation Effect of Recording Parameters Error on Imaging Performance of Holographic Grating in On-Line Spectral Diagnose [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(03): 857-863. |
[5] |
JIA Li-hua1, WANG Yi-ding1, SUN Cheng-lin2, 3*, LI Zhan-long2, LI Zuo-wei2, WANG Li-jun3 . Study of Biological Molecules in Water by Using the Resonance Raman Spectra in Liquid-Core Optical Fiber[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(10): 2686-2688. |
[6] |
CHEN Wei1,ZHOU Mi2*,ZUO Jian2,WANG Li-na3,GAO Shu-qin2,LU Guo-hui2,LI Zhan-long2,LI Zuo-wei2 . FTIR Spectroscopic Investigations on the Difference in Cartilage Composition between Youth and Elder[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(04): 683-685. |
|
|
|
|