光谱学与光谱分析 |
|
|
|
|
|
Design Method of Convex Master Gratings for Replicating Flat-Field Concave Gratings |
ZHOU Qian, LI Li-feng |
State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing 100084, China |
|
|
Abstract Flat-field concave diffraction grating is the key device of a portable grating spectrometer with the advantage of integrating dispersion, focusing and flat-field in a single device. It directly determines the quality of a spectrometer. The most important two performances determining the quality of the spectrometer are spectral image quality and diffraction efficiency. The diffraction efficiency of a grating depends mainly on its groove shape. But it has long been a problem to get a uniform predetermined groove shape across the whole concave grating area, because the incident angle of the ion beam is restricted by the curvature of the concave substrate, and this severely limits the diffraction efficiency and restricts the application of concave gratings. the authors present a two-step method for designing convex gratings, which are made holographically with two exposure point sources placed behind a plano-convex transparent glass substrate, to solve this problem. The convex gratings are intended to be used as the master gratings for making aberration-corrected flat-field concave gratings. To achieve high spectral image quality for the replicated concave gratings, the refraction effect at the planar back surface and the extra optical path lengths through the substrate thickness experienced by the two divergent recording beams are considered during optimization. This two-step method combines the optical-path-length function method and the ZEMAX software to complete the optimization with a high success rate and high efficiency. In the first step, the optical-path-length function method is used without considering the refraction effect to get an approximate optimization result. In the second step, the approximate result of the first step is used as the initial value for ZEMAX to complete the optimization including the refraction effect. An example of design problem was considered. The simulation results of ZEMAX proved that the spectral image quality of a replicated concave grating is comparable with that of a directly recorded concave grating.
|
Received: 2008-06-08
Accepted: 2008-09-12
|
|
Corresponding Authors:
ZHOU Qian
E-mail: q-zhou03@mails.thu.edu.cn
|
|
[1] WU Guo-an(吴国安). Design of Spectroscopic Instruments(光谱仪器设计). Beijing: Science Press(北京:北京科学出版社),1978. [2] Pavlycheva N K. Sov. J. Opt. Technol., 1979, 46(7): 394. [3] Hutley M C. Diffraction Gratings. Academic Press, 1980. [4] ZHOU Qian, ZENG Li-jiang, LI Li-feng(周 倩,曾理江,李立峰). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2008,28(7):1673. [5] LI Li-feng, Chandezon J, Granet G, et al. Appl. Opt., 1999, 38(2): 304. [6] Singh S. Optics and Laser Technology, 1999, 31: 195. [7] Namioka T. J. Opt. Soc. Am., 1959, 49(5): 446. [8] Namioka T. J. Opt. Soc. Am., 1959, 49(5): 460. [9] Namioka T. J. Opt. Soc. Am., 1959, 49(10): 951. [10] Noda H, Namioka T, Seya M. J. Opt. Soc. Am., 1974, 64(8): 1031. [11] ZEMAX Reference Manual. ZEMAX Development Corp., 2003. [12] LI Chao-ming, WU Jian-hong, TANG Min-xue(李朝明,吴建宏,唐敏学). Laser Journal(激光杂志), 2005, 26(2): 57. [13] LIN Hui, ZHANG Li-chao, LI Li-feng, et al. Opt. Lett., 2008, 33(5): 485. [14] ZHAO Jin-song, LI Li-feng, WU Zhen-hua(赵劲松, 李立峰, 吴振华). Acta Optica Sinica(光学学报), 2004, 24(9): 1285. [15] LIN Hua, LI Li-feng, ZENG Li-jiang. Chin. Opt. Lett.,2005, 3(2): 63. [16] ZHOU Qian, LI Li-feng, ZENG Li-jiang. Proc. SPIE,2007, 6832: 68320W. |
[1] |
LI Xin-quan1, 2,ZHANG Jun-qiang1, 3*,WU Cong-jun1,MA Jian1, 2,LU Tian-jiao1, 2,YANG Bin3. Optical Design of Airborne Large Field of View Wide Band Polarization Spectral Imaging System Based on PSIM[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 250-257. |
[2] |
ZHENG Zhi-zhong1,2, YANG Zhong1*, XIU Lian-cun2, DONG Jin-xin2, CHEN Chun-xia2, GAO Yang2, YU Zheng-kui2. Design of a SWIR Offner Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2267-2272. |
[3] |
MAO Jing-hua1, 2, WANG Yong-mei1,2*, SHI En-tao1, ZHANG Zhong-mou1, JIANG Fang1. Study on the Slitfunction Test Method Based on Hyperspectral Imaging Instrument[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(04): 1286-1290. |
[4] |
CUI Ji-cheng1, 2, LIU Yu-juan1, 2, PAN Ming-zhong1, TANG Yu-guo1 . The Integrative Design for Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(03): 839-843. |
[5] |
KONG Peng1,2, TANG Yu-guo1, Bayanheshig1*, LI Wen-hao1, CUI Jin-jiang3 . Optimization of Broad-Band Flat-Field Holographic Concave Grating without Astigmatism [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(02): 565-569. |
[6] |
YU Hai-li1,2 ,QI Xiang-dong1,Bayanheshig1,TANG Yu-guo1 . Solving Resolution of Diffraction Gratings Using Coefficients of Zernike Polynomials [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(01): 264-267. |
[7] |
LIU Yu-juan1, 2, TANG Yu-guo1*, CUI Ji-cheng1, 2, Bayanheshig1 . Small Imaging Spectrometer for the Inspection of Fruit Quality [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(01): 283-286. |
[8] |
LUO Biao, WEN Zhi-yu*,WEN Zhong-quan,CHEN Li,QIAN Rong-rong. Near Infrared Spectroscopy System Structure with MOEMS Scanning Mirror Array[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(11): 3154-3157. |
[9] |
ZENG Jin1,2, Bayanheshig1*, LI Wen-hao1, ZHANG Jin-ping1,2 . One Step Method to Design Concave Holographic Grating for Monochromator[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(09): 2586-2589. |
[10] |
KONG Peng1,2, Bayanheshig1*, LI Wen-hao1, TANG Yu-guo1, CUI Jin-jiang3 . Effect of Curvature Radius Error on the Flat-Field Holographic Concave Grating Resolution and Its Compensation [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(05): 1435-1438. |
[11] |
ZHU Ling-jian1,2, TANG Xiao-jun1, QIU Zong-ming2,LIU Jun-hua1,ZHANG Zhong-hua3,ZHANG Yong1 . A Method for Quantitative Analysis System of Alkane Gaseous Mixture with Near Infrared Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(01): 69-72. |
[12] |
WANG Ling-fang, WEN Zhi-yu, XIANG Xian-yi. Design and Simulation of the NIR Micro-Spectrometer Optical System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(06): 1721-1725. |
|
|
|
|