Optical System Design of High-Precision Line-Scanning Spectral Confocal Displacement Sensor |
YANG Wei-guang1, 2, ZHANG Zhou-feng1*, QI Mei-jie1, YAN Jia-yue1, 2, CHENG Mo-han1, 2 |
1. Laboratory of Spectral Imaging Technology, Xi'an Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Xi'an 710119, China
2. University of Chinese Academy of Sciences, Beijing 100049, China
|
|
|
Abstract Spectral confocal displacement sensor is a new geometric precision measurement sensor with high accuracy, high efficiency, and non-contact technical advantages. It is now widely used in measuring micro or macro geometric quantities. Conventional geometric measurement sensors use contact mechanical probes, which cause damage to the surface of the object, making it difficult to meet the needs of non-destructive measurement in modern manufacturing. Unlike conventional optical systems that require correction for axial chromatic aberration, spectral confocal displacement sensors use axial chromatic aberration to establish the relationship between displacement and wavelength. However, most current research on spectral confocal displacement sensing technology has focused on point sweep. This technique can only obtain the geometric information of a single point, which greatly limits the efficiency in the practical application of precision measurement of larger areas and requires high back-end data processing and cumbersome data reconstruction. This study designs a line-swept spectral confocal displacement sensor system with submicron resolution to address this technical drawback. This study analyzes the principle of the line-swept spectral confocal displacement sensor and the detailed design of a large-range dispersive objective lens and a high spectral resolution spectral spectroscopic unit is carried out. By optimizing the optical path structure of the dispersive objective and spectral spectroscopy unit and balancing the aberrations, the RMS radius of each field of view of the full system is less than 5.5 μm, and good imaging quality is obtained. The results show that the full system has a resolution of 0.8 μm at a scan line length of 10 mm and an axial range of 3mm. This study has a broad application prospect in high-efficiency and high-precision geometric precision measurement.
|
Received: 2023-06-05
Accepted: 2023-12-20
|
|
Corresponding Authors:
ZHANG Zhou-feng
E-mail: zhangzhoufeng@opt.ac.cn
|
|
[1] GAO Xu, LI Shu-hang, MA Qing-lin, et al(高 旭, 李舒航, 马庆林,等). Chinese Optics(中国光学), 2019, 12(4): 741.
[2] ZHANG Ya-li, YU Qing, SHANG Wen-jian, et al(张雅丽,余 卿,尚文键). Chinese Optics(中国光学), 2022, 15(3): 514.
[3] Wang S, Zhao Q L. Measurement, 2022, 202: 111825.
[4] WANG Yong-hong, ZHANG Qian, HU Yin, et al(王永红, 张 倩, 胡 寅, 等). Chinese Optics(中国光学), 2021, 14(3): 447.
[5] CHENG Zi-yi, LU Rong-sheng, MAO Cui-li(程子怡, 卢荣胜, 毛翠丽). Laser & Optoelectronics Progress(激光与电子学进展), 2020, 57(7): 204.
[6] DONG Jing-xin, WAN Song, ZHOU Li-ping, et al(董晶鑫,万 松,周丽平,等). Optics and Precision Engineering(光学精密工程), 2023, 31(7): 1000.
[7] WANG Zi, SHI Jun-kai, CHEN Xiao-mei, et al(王 梓, 石俊凯, 陈晓梅,等). Semiconductor Optoelectronics(半导体光电), 2022, 43(4): 752.
[8] Jeong D, Park S J, Jang H, et al. Sensors, 2020, 20(24): 7347.
[9] Zakrzewski A, Jurewicz P, Koruba P, et al. Applied Optics, 2021, 60(11): 3232.
[10] Yu Qing, Zhang Kun, Zhou Ruilan, et al. IEEE Photonics, 2018, 10(6). doi: 10.1109/phot.2018.2875562.
[11] Chen Cheng, Leach R, Wang Jian, et al. Optics Express, 2021, 29(5): 7179.
[12] Wang Yongqing, Xi Mengmeng, Liu Haibo, et al. Optics & Laser Technology, 2021, 134: 106569.
[13] Bai Jiao, Wang Yingzuo, Wang Xiaohao, et al. Nanomanufacturing and Metrology, 2021, 4: 247.
[14] Seppäl J, Niemelä K, Lassila A. Measurement Science and Technology, 2018, 29(5): 054008.
[15] Hu Hao, Mei Shuang, Fan Liming, et al. Review of Scientific Instruments, 2021, 92(5): 053707.
[16] Novak J, Miks A. Optik, 2005, 116(4): 165.
[17] Mouroulis P, Green R O. Optical Engineering, 2018, 57(4): 040901.
[18] Warren M A, Simis S G H, Martinez-Vicente V, et al. Remote Sensing of Environment, 2019, 225: 267.
[19] LIU Yin-nian, XUE Yong-qi(刘银年, 薛永祺). Acta Geodaetica et Cartographica Sinica(测绘学报), 2023, 52(7): 1045.
[20] YU Lei(于 磊). Infrared and Laser Engineering(红外与激光工程),2022,51(1):20210940.
[21] LIU Bing, LIU Ying, ZHANG Xiao-long, et al(刘 兵, 刘 英, 张晓龙,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2016, 36(5): 1543.
[22] GAO Zhen-yu, FANG Wei, SONG Bao-qi, et al(高震宇, 方 伟, 宋宝奇,等). Acta Photonica Sinica(光子学报), 2015, 44(10): 65.
|
[1] |
YUAN Yuan1, ZHANG Tian-yao1*, ZHANG Zhao-hui1, ZHAO Xiao-yan1, LI Xing-yue1, LI Bo-yang1, WU Xian-hao1, XU Bo1, YAN Jian-feng2, SUN Pu2, CAO Can3. Non-Contact Characterization Method of Birefringence Crystal Based on Terahertz Time-Domain Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(08): 2334-2339. |
[2] |
GUO He-qing1, 2, ZHANG Sheng-zi2*, LIU Xiao-meng2, JING Xu-feng1, WANG Hong-jun2. Research Progress of the Real-Time Detection System of Bioaerosols Based on Fluorescence Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(08): 2339-2347. |
[3] |
JIANG Xiao-yu1, 2, LI Fu-sheng2*, WANG Qing-ya1, 2, LUO Jie3, HAO Jun1, 2, XU Mu-qiang1, 2. Determination of Lead and Arsenic in Soil Samples by X Fluorescence Spectrum Combined With CARS Variables Screening Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(05): 1535-1540. |
[4] |
WENG Hai-yong1, HUANG Jun-kun1, WAN Liang2, YE Da-peng1*. Rapidly Detecting Chlorophyll Content in Oilseed Rape Based on Spectral Reconstruction and Its Device Development[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(01): 210-215. |
[5] |
ZHANG Tian-yu, QU Xing-hua, ZHANG Fu-min*, PENG Bo. Study on the Large-Scale Distance Measurement Method for Femtosecond Laser Based on Frequency Scanning and Optical Sampling[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(09): 2708-2712. |
[6] |
CHEN Chun-xia1, 2, XIU Lian-cun1, 2*, GAO Yang1, 2. Research on Data Processing of Core Spectral Scanner[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(05): 1630-1636. |
[7] |
WANG Zi-ru1, LIU Ming-hui2, LIU En-kai1, DONG Zuo-ren2, CAI Sheng-wen1, YIN Lei1, LIU Feng1. Method and Application for Raman Spectra SNR Evaluation Based on Extreme Points Statistics[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(04): 1080-1085. |
[8] |
LIU Jia-nan1, 2*, CUI Ji-cheng1, YIN Lu1, 2, SUN Ci1, CHEN Jian-jun1, 2, ZHANG Rui1, 2, LIU Jian-li1, 2. Analysis and Design of Pre-Imaging System of Integral Field Imaging Spectrometer Based on Lenslet Array[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3269-3272. |
[9] |
ZHANG Yu-feng1, LI Ming1, DAI Jing-min2, SHAO Zhu-feng1, WU Yuan-qing1. Measuring Method of the Spectral Absorptivity for Solar Selective Absorption Coatings at High Temperature[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(06): 1814-1818. |
[10] |
SHEN Chun-yang1, 2, CUI Ji-cheng1*, SUN Ci1, WANG Wei1, 2, CHEN Jian-jun1, 2, LI Xiao-tian1. A Detection System Design of Echelle Diffraction Efficiency and Stray Coefficient[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2603-2609. |
[11] |
BIN Jun1, FAN Wei1*, ZHOU Ji-heng1*, LI Xin1, LIANG Yi-zeng2 . Application of Intelligent Optimization Algorithms to Wavelength Selection of Near-Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(01): 95-102. |
[12] |
ZHANG Yu-feng1, DAI Jing-min2, LU Xiao-dong1, SHAO Zhu-feng1, WU Yuan-qing1 . Correction Methods of Temperature Drift for Infrared Spectral Emissivity Measurement System [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(09): 3003-3007. |
[13] |
ZHANG Jian-feng1, PAN Sun-qiang1, LIN Xiao-lu1,2, HU Peng-bing1, CHEN Zhe-min1 . Research on On-Line Calibration Based Photoacoustic Spectrometry System for Monitoring the Concentration of CO2 in Atmosphere[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(01): 1-5. |
[14] |
FENG Ming-chun, LIU Wen-qing, XU Liang*, GAO Min-guang, WEI Xiu-li, TONG Jing-jing, LI Xiang-xian . Optical Path Difference Analysis and Simulation of Four Typical Rotary Type Interferometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(11): 3214-3219. |
[15] |
ZHAO Ying1, ZHAO Xue-hong1,2*, WANG Zhe1, ZHANG Rui1,3, WANG Yan1 . A New Method for Eliminating Background Signal Drift to Improve the Detection Precision in Continuous Harmonic Detection [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(11): 3224-3229. |
|
|
|
|