Identification of Fine Wool and Cashmere by Using Vis/NIR Spectroscopy Technology
WU Gui-fang1,2,ZHU Deng-sheng3,HE Yong1*
1. College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310029, China 2. College of Mechanical and Electrical Engineering, Inner Mongolia Agriculture University, Huhhot 010018, China 3. Jinhua College of Profession and Technology, Jinhua 321017, China
Abstract:As a rapid and non-destructive methodology, near infrared spectroscopy technique has been attracting much attention recently. The present study applied Vis/NIR spectra to the identification of cashmere and fine wool fiber. Cashmere and fine wool are resemble in superficies, but they differs in diameter, height, thickness, angle of inclination, and marginal morphology of surface scale. Although researchers both at home and abroad did a lot researches and experiments to distinguish fine wool from cashmere, the resolution of cashmere and fine wool is still not satisfactory, and it is always a challenging task to differentiate and recognize fine wool and cashmere. This paper presents an automatic recognition scheme for the fine wool fiber and cashmere fiber by Vis/NIR spectroscopy technique, aiming at the characteristics of Vis/NIR spectra of cashmere and fine wool. One mixed algorithm was presented to discriminate cashmere and fine wool with principal component analysis (PCA) and artificial neural network (ANN). Preliminary qualitative analysis model has been built: Vis/NIRS spectroscopy diffuse techniques were used to collect the spectral data of cashmere and fine wool, and two kinds of data pretreatment methods were applied: the standard normal variate (SNV) was used for scatter correction. Savitzky-Golay with the segment size 3 was used as the smoothing way to decrease the noise processed. Following the pretreatment, spectral data were processed using principal component analysis, 6 principal components (PCs) were selected based on the reliabilities of PCs of 99.8%, and the scores of these 6 PCs would be taken as the input of the three-layer back-propagation (BP) artificial neural network (BP-ANN). The BP-ANN was trained with samples in calibration collection and predicted the samples in prediction collection were predicted. Experiments demonstrate that the system works quickly and effectively, and has remarkable advantages in comparison with the previous systems. The result indicated that a model had been built to discriminate cashmere from fine wool using Vis/NIR spectra method combined with PCA-BP technology.
吴桂芳1,2,朱登胜3,何勇1*. 可见-近红外光谱用于鉴别山羊绒与细支绵羊毛的研究[J]. 光谱学与光谱分析, 2008, 28(06): 1260-1263.
WU Gui-fang1,2,ZHU Deng-sheng3,HE Yong1*. Identification of Fine Wool and Cashmere by Using Vis/NIR Spectroscopy Technology. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28(06): 1260-1263.
[1] PENG Wei-liang, JIANG Yao-xing(彭伟良, 蒋耀兴). Research and Exploration in Laboratory(实验室研究与探索), 2005 24(4): 28. [2] DENG Li-li, JIANG Feng-qin(邓丽丽, 姜风琴). Journal of Dalian Institute of Light Industry(大连轻工学院学报), 2003, 22(3): 203. [3] LIU Qi-guo, HOU Xiu-liang(刘启国,侯秀良). Journal of Nantong Institute of Technology(南通工学院学报), 1999, 15(4): 25. [4] PENG Wei-liang, JIANG Yao-xing, YUAN Chang-tai(彭伟良, 蒋耀兴, 袁长泰). Shanghai Textile Science & Technology(上海纺织科技), 2005, 33(11): 11. [5] QIN Shi-zhong(秦士忠). Inspection and Quarantine(检验检疫科学), 2005, 15(6): 58. [6] Alan M L, Moon S K, Chen Y R, et al. Computers and Electronics in Agriculture, 2006, 54(1): 22. [7] Baye T M, Pearson T C, Settles A M. Journal of Cereal Science, 2006, 43(2): 236. [8] WANG Duo-jia, ZHONG Jiao-e, HU Xiang-na, et al(王多加, 钟娇娥, 胡祥娜, 等). Chinese Journal of Analytical Chemistry(分析化学), 2003, 31(7): 892. [9] WANG Duo-jia, ZHOU Xiang-yang, JIN Tong-ming, et al(王多加, 周向阳, 金同铭, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2004, 24(4): 447. [10] Andersen C M, World J P, Mortensen G. International Diary Journal, 2006, 16: 1483. [11] Lachenmeier D W. Food Chemistry, 2007 101: 825. [12] Carlomagno G, Capozzo L, Attolico G Distante. Infrared Physics & Technology, 2004, 46: 23. [13] Seregély Z, Farkas J, Tuboly E, et al. Chemometrics and Intelligent Laboratory Systems, 2006, 82(1): 115. [14] CHEN Da, WANG Fang, SHAO Xue-guang, et al(陈 达, 王 芳, 邵学广, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2004, 24(6): 672. [15] CHU Xiao-li, YUAN Hong-fu, LU Wan-zhen(褚小立, 袁洪福, 陆婉珍). Analytical Instrumentation(分析仪器), 2006, (2): 1. [16] TIAN Li-rong, TANG Zhen, LIU Fu-qiang, et al(田丽容, 汤 真, 刘富强, 等). Analytical Laboratory(分析试验室), 2001, 20(1): 79. [17] HE Yong, LI Xiao-li, SHAO Yong-ni(何 勇, 李晓丽, 邵咏妮). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2006, 26(5): 850. [18] JI Hai-yan, YAN Yan-lu(吉海彦, 严衍禄). Journal of Instrumental Analysis(分析测试学报) , 1999, 18(3): 12. [19] HE Yong, LI Xiao-li(何 勇, 李晓丽). Journal of Infrared and Millimeter Waves(红外与毫米学报), 2006, 25(3): 192. [20] CHU Xiao-li, YUAN Hong-fu, LU Wan-zhen(褚小立, 袁洪福, 陆婉珍). Progress in Chemistry(化学进展), 2004, 16(4): 528.