Principal Component Extraction Used for the Interpretation of RS-FTIR Spectra
HU Lan-ping1,2,ZHANG Lin1,LI Yan1,ZHANG Li-ming1,REN Yi-bo1, YU Bai-hua1,WANG Jun-de1*
1. Laboratory of Advanced Spectroscopy, Nanjing University of Science and Technology, Nanjing 210014, China 2. Laboratory of Analytical Chemistry, School of Chemistry and Chemical Engineering, Nantong University, Nantong 226006, China
Abstract:A method for interpretation of remote sensing FTIR spectra was set up based on ANN model. Considering long training time and over-fitting problem of ANN, two methods, partial least squares (PLS) and principal component analysis (PCA), were utilized to extract principal components of spectra, process time decrease from about 30 minutes to a few seconds. Meanwhile, the idea of calibration transfer was used to overcome the limitation of calibration model in remote sensing FTIR spectra analysis. With the optimization of ANN model, four-component mixtures of acetone, benzene, chloroform and methanol were predicted in a remote sensing and real-time way while the calibration model was built with EPA data. The best performance was yielded with PLS-ANN model, and the root mean square error (RMSE) of acetone, benzene, chloroform and methanol were 0.043,0.031,0.034 and 0.051 respectively, which confirm the real-time, correct and quick analysis of remote sensing FTIR in air monitoring.
胡兰萍1,2,张琳1,李燕1,张黎明1,任翌博1,于佰华1,王俊德1* . 主成分提取在遥感FTIR谱图解析中的应用[J]. 光谱学与光谱分析, 2007, 27(11): 2193-2196.
HU Lan-ping1,2,ZHANG Lin1,LI Yan1,ZHANG Li-ming1,REN Yi-bo1, YU Bai-hua1,WANG Jun-de1* . Principal Component Extraction Used for the Interpretation of RS-FTIR Spectra. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(11): 2193-2196.
[1] LI Yan, WANG Jun-de(李 燕,王俊德). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2003, 23(6):1104. [2] Li Yan, Wang Junde, Chen Zuoru, et al. Anal. Lett.,2001, 34(12):2203. [3] Li Yan, Yang Shulin, Wang Junde, et al. Spectrosc. Lett.,1999, 32(3):421. [4] LI Yan, WANG Jun-de, WANG Lian-jun(李 燕,王俊德,王连军). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2000,20(4):477. [5] Yang H S, Griffiths P R. Anal. Chem.,1999, 71(3):751. [6] Yang H S, Griffiths P R. Anal. Chem.,1999, 71(12):3356. [7] Despogne F, Massart D L, Chabot P. Anal. Chem., 2000, 72(7): 1657. [8] Hadjiiski L, Geladi P. Chemom. Intell. Lab. Syst., 1999, 49(1): 91. [9] Eklov T, Martensson P, Lundstrom I. Anal. Chim. Acta,1999, 381:221. [10] Srivastava A K. Sensor Actuat. B,2003, 96(1):24. [11] Jiang J H, Berry R J, Siesler H W, et al. Anal. Chem., 2002, 74(12):3555. [12] Koehler F W Ⅳ, Small G W. Anal. Chem.,2000, 72(7):1690. [13] ZHANG Lin, ZHANG Li-ming, LI Yan, et al(张 琳, 张黎明, 李 燕, 等). Chinese Journal of Analytical Chemistry(分析化学),2005, 33(12):1709. [14] ZHANG Lin, ZHANG Li-ming, LI Yan, et al(张 琳, 张黎明, 李 燕, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2006, 26(9): 1614. [15] Woody N A, Feudale R N, Myles A J, et al. Anal. Chem.,2004, 76(9):2595. [16] Zhang Lin,Small G W,Arnold M A. Anal. Chem.,2003, 75(21):5905. [17] Blank T B, Sum S T, Brown S D. Anal. Chem., 1996, 68(17): 2987. [18] Wang Yongdong, Veltkamp D J, Kowalski B R. Anal. Chem., 1991, 63(23): 2750. [19] Bjarnestad S, Dahlman O. Anal. Chem., 2002, 74(22): 5851. [20] Pereira R CC, Skrobot V L, Castro E V R, et al. Energy & Fuels, 2006, 20(3): 1097.