光谱学与光谱分析 |
|
|
|
|
|
A Surface Plasmon Micro-Ring Sensor Suitable for Humidity Sensing |
LI Zhi-quan1, AN Dong-yang1, ZHANG Xin1, ZHAO Ling-ling1, SHA Xiao-peng1, GUO Shi-liang1, LI Wen-chao2 |
1. College of Electrical Engineering, Yanshan University, Qinghuangdao 066004, China 2. School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China |
|
|
Abstract Temperature is a very important parameter in scientific research, production and life. Almost all the properties of materials are related to temperature. The precise measurement of the temperature is a very important task, so the temperature sensor is widely used as a core part in the temperature measuring instrument. A novel surface plasmon micro-ring sensor suitable for humidity sensing is presented in this paper. The sensor uses a multi-layered surface plasmon waveguide structure and choosing Polyimide (Polyimide, PI) as the moisture material. We get the transfer function of surface plasmon micro-ring sensor by using transfer matrix method. Refractive indexes of Polyimide and the multilayer waveguide structure change as environment relative humidity changes, thus leading to an obvious peak drift of output spectrum. The paper mainly discusses the influence of the changes of the refractive index of humidity-sensing parts on the output spectrum, and the transmission characteristics of multilayer waveguide structure. Through the finite element method and the theoretical simulation of Matlab,We can draw:When the length between the two coupling points of the U-shaped waveguide is an integer multiple of circumference of the micro-ring, an obvious drift in the horizontal direction appears, the free spectral range (FSR) doubled and the sensitivity is 0.000 5 μm/%RH; When the external environment relative humidity RH changes from 10% to 100% RH, scatter is change between including (including 0.005 m to 0.005 m, compared to other humidity sensor, the Sensitivity of sensor improves 10~50 times and the transmission is very stable. Results show that the design of surface plasma micro ring sensors has better sensitivity, stable performance and can be used in the humidity measurement, achieving a high sensitivity in the sense of humidity when the wide range of filter frequency selection is taken into account, and providing a theoretical basis for the preparation of micro-optics.
|
Received: 2014-05-23
Accepted: 2014-08-25
|
|
|
[1] Marcatili E A. J. Bell. Labs. Technical Journal, 1969,48: 2103. [2] Li Q, Liu F, Zhang Z. J. Lightw. Technol., 2008, 26: 3744. [3] ZHANG Bin, MAO Lu-hong, XIE Sheng, et al(张 彬,毛陆虹,谢 生,等). Acta Optica Sinica(光学学报), 2010, 30: 537. [4] Liang D, Fiorentino M, Srinivasan S. IEEE Journal of Selected Topics in Quantum Electronics,2011,17:1528. [5] Mo Wenqin, Hua Mingwu, Gao Dingshan, et al. Chinese Optics Letters, 2009, 7: 798. [6] RAO Yun-jiang, CHEN Yi-huai, WU Yu, et al(饶云江, 陈一槐, 吴 宇, 等). Journal of University of Electronic Science and Technology of China(电子科技大学学报),2012,41. [7] TU Xing-hua(涂兴华). Journal of Atmospheric and Environmental Optics(大气与环境光学学报), 2009, 4: 462. [8] Huang X F, Sheng D R, Cen K F, et al. Sensors Actuat, 2007, 127: 518. [9] Lourdes Alwis, Tong Sun, Kenneth V Grattan. IEEE Sensors Journal, 2013, 13: 767. [10] ZHANG Hui-fang, ZHAO Yu-jing, TAO Feng(张惠芳, 赵玉静, 陶 峰). Acta Photonica Sinica(光子学报),2010, 39(12): 2234. [11] Kong X T, Yan W G, Li Z B. Optics Express, 2012, 20: 12133. [12] LI Zhi-quan, LI Xiao-yun, SUN Yu-chao, et al(李志全,李晓云,孙宇超,等). Acta Optica Sinica(光学学报), 2012, 32: 0723001. [13] Shibata H, Ito M, Asakursa M. IEEE Transactions on Instrumentation and Measurement, 1996, 45: 564. |
[1] |
WU Shu-jia1, 2, YAO Ming-yin2, 3, ZENG Jian-hui2, HE Liang2, FU Gang-rong2, ZENG Yu-qi2, XUE Long2, 3, LIU Mu-hua2, 3, LI Jing2, 3*. Laser-Induced Breakdown Spectroscopy Detection of Cu Element in Pig Fodder by Combining Cavity-Confinement[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1770-1775. |
[2] |
ZHANG Rong1, 2, DUAN Ning1, 3, JIANG Lin-hua1, 3*, XU Fu-yuan3, JIN Wei3, LI Jian-hui1. Study on Optical Path Optimization for Direct Determination of
Spectrophotometry of High Concentration Hexavalent Chromium
Solution by Ultraviolet Visible Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1829-1837. |
[3] |
SI Gan-shang1, 2, LIU Jia-xiang1, LI Zhen-gang1, 2, NING Zhi-qiang1, 2, FANG Yong-hua1, 2*, CHENG Zhen1, 2, SI Bei-bei1, 2, YANG Chang-ping1, 2. Raman Signal Enhancement for Liquid Detection Using a New Sample Cell[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 712-717. |
[4] |
ZHANG Xue-fei1, DUAN Ning1, 2*, JIANG Lin-hua1, 2*, CHENG Wen2, YU Zhao-sheng3, LI Wei-dong2, ZHU Guang-bin4, XU Yan-li2. Study on Stability and Sensitivity of Deep Ultraviolet Spectrophotometry Detection System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(12): 3802-3810. |
[5] |
LI Yan-yan1, 2, LUO Hai-jun1, 2*, LUO Xia1, 2, FAN Xin-yan1, 2, QIN Rui1, 2. Detection of Craniocerebral Hematoma by Array Scanning Sensitivity Based on Near Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 392-398. |
[6] |
LI Ming1, 2, NI Long1, WANG Meng1, 2*, ZHU Zhong-xu1, YUAN Chuan-jun1, 2, WU Jian3*. Research Progress on Evaluating the Effects of Nanomaterial-Based Development of Latent Fingerprints[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2670-2680. |
[7] |
LIU Qing-sheng1, YANG De-wang2, GUO Jin-jia1*, YAN Ao-shuang1, ZHENG Rong-er1. Raman Spectroscopy for Gas Detection Using a Folded Near-Concentric Cavity[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(11): 3390-3393. |
[8] |
TIAN Xing1, 2, 3, CAO Yuan1, 3, WANG Jing-jing1, 3, CHEN Jia-jin1, LIU Kun1, TAN Tu1, WANG Gui-shi1, GAO Xiao-ming1*. High Sensitivity Detection of Two-Component CH4/H2O Based on Off-Axis Cavity Enhanced Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(10): 3078-3083. |
[9] |
WANG Zi-ren, WANG Chang-hua, HU Fang-fei, LI Ji-dong*. Quantification of Trace Impurities in Graphite by Glow Discharge Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(04): 1256-1261. |
[10] |
MAO Feng1, WANG Ming-jia2*. Low-Light-Level Readout Based on Quantum Dots-in-Well Photodetector at Room Temperature[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(03): 877-881. |
[11] |
TANG Qian1, GUO Li-xin1*, ZHAO Bao-chang2. An Allotype Double H-V Depolarizer for Hyperfine Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3913-3919. |
[12] |
ZHA Shen-long1, 2, LIU Kun1, ZHU Gong-dong1, TAN Tu1, WANG Lei1, WANG Gui-shi1, MEI Jiao-xu1, GAO Xiao-ming1*. Acetylene Detection Based on Resonant High Sensitive Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(09): 2673-2678. |
[13] |
JIANG Ying1, ZHANG Chong-zhen1, LIANG Da-kai2, LU Ji-yun3. Optimal Research on the Strain Sensitivity of Polarization Maintaining Fiber Loop Mirror[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(05): 1576-1580. |
[14] |
WANG Li, TAN Lin-qiu, CHANG Bo, LU Geng-geng, GAO Fei, HUA Deng-xin* . Doppler Lidar with High Sensitivity and Large Dynamic Range for Atmospheric Wind Measurement[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(03): 958-963. |
[15] |
LI Wen-chao2, MENG Xiao-yun1, PIAO Rui-qi1, ZHAO Jing-jing1, LI Zhi-quan1*, TONG Kai1, GU Er-dan1 . Brand-New Ge20Ga5Sb10S65 Prism Biosensor Based on Inverted SPR [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(02): 571-576. |
|
|
|
|