Study on Stability and Sensitivity of Deep Ultraviolet Spectrophotometry Detection System |
ZHANG Xue-fei1, DUAN Ning1, 2*, JIANG Lin-hua1, 2*, CHENG Wen2, YU Zhao-sheng3, LI Wei-dong2, ZHU Guang-bin4, XU Yan-li2 |
1. School of Materials Science and Engineering, Anhui University of Science and Technology, Huainan 232001, China
2. College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
3. Tianjin Xinke Environmental Protection Technology Co., Ltd., Tianjin 300457, China
4. School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China
|
|
|
Abstract The existing national standard photometric method can not directly determine the pollutants in the production process of continuous reaction units in the process industry. The main reason is that the absorption of ultraviolet light by oxygen in the deep ultraviolet region interferes with the detection of target substances by ultraviolet spectrophotometer, resulting in a certain degree of deviation in the detection results. Therefore, the key to solving this problem is to stably obtain the highly sensitive photometric information of substances with different characteristic wavelengths in the deep ultraviolet region. In this study, a nitrogen transmission and distribution system was installed based on a UV spectrophotometer. At the same time, an automatic injection flow cell and tray are designed to realize automatic sample injection between detection gaps. The nitrogen flows into the optical system area, sample room and data receiving area of the instrument is accurately controlled at 6, 2 and 3 L·min-1 respectively, so that the average value of the baseline flatness of the instrument is reduced from 0.108 to 0.010, which is 90.7% less than the air conditioner. Comparing the differences in the absorbance, sensitivity, sensitivity change and linear range of SO2-4 between air and nitrogen atmospheres, reveals that the absorbance and sensitivity of detection results in nitrogen atmosphere are improved in the range optical pathlengths b=1~100 mm. The sensitivity change increases from 10.42% to 30.65% when b=1 mm to b=100 mm, but the linear range decreases from 0.09 to 0.03 g·L-1 with increasing of optical path lengths. It shows that the nitrogen transmission and distribution system successfully inhibits the attenuation of UV intensity in the detection process. Compared with ion chromatography, one of the common methods for detecting SO2-4, this method has the advantages of convenient detection, stable and reliable detection results and good economic benefits, laying a foundation for industrial application.
|
Received: 2021-12-06
Accepted: 2022-03-30
|
|
Corresponding Authors:
DUAN Ning, JIANG Lin-hua
E-mail: ningduan2020@163.com;jianglinhuann@163.com
|
|
[1] GB11914—1989 Water Quality-Determination of the Chemical Oxygen Demand-Dichromate Method(GB11914—1989水质化学需氧量的测定重铬酸盐法), 1989. Ministry of Ecology and Environment of the People’s Republic of China(中华人民共和国生态环境部).
[2] GBT7485—1987 Water quality-Determination of Total Arsenic-Silver Diethyldithiocarbamate Spectrophotometric Method(GBT7485—1987水质总砷的测定二乙基二硫代氨基甲酸银分光光度法), 1987. Ministry of Ecology and Environment of the People’s Republic of China(中华人民共和国生态环境部).
[3] GBT7467—1987 Water Quality-Determ Ination of Chromium (Ⅵ)-1,5 Diphenylcarbohydrazide Spectrophotometric Method(GBT7467—1987水质六价铬的测定二苯碳酰二肼分光光度法), 1987. Ministry of Ecology and Environment of the People’s Republic of China(中华人民共和国生态环境部).
[4] Sanchez-Hachair A, Hofmann A. Comptes Rendus Chimie, 2018, 21(9): 890.
[5] Singh K, Kumar A. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2019, 211: 148.
[6] Uzunboy S, Karakaş Ö, Demirci-Çekiç S, et al. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2021, 260: 119941.
[7] Krish A, Streicher J W, Hanson R K. Journal of Quantitative Spectroscopy and Radiative Transfer, 2020, 247: 106959.
[8] Wang Lin, Zhang Yungang, Zhou Xue, et al. Sensors and Actuators B: Chemical, 2019, 281: 514.
[9] WANG Ming-xing, ZHENG Xun-hua(王明星,郑循华). Introduction to Atmospheric Chemistry(大气化学概论). Beijing: China Meteorological Press(北京:气象出版社), 2005.
[10] Li Kai, Wu Xi, Chen Zhiming, et al. Journal of Analytical Atomic Spectrometry, 2020, 35(11): 2656.
[11] He Lin, Li Peixia, Li Kai, et al. Journal of Analytical Atomic Spectrometry, 2021, 36(6): 1193.
[12] Ozaki Y, Morisawa Y, Ikehata A, et al. Applied Spectroscopy, 2012, 66(1): 1.
[13] Tanabe I, Shimizu M, Kawabata R, et al. Sensors and Actuators A: Physical, 2020, 301: 111661.
[14] Weissler G L, Lee P, Mohr E I. Journal of the Optical Society of America, 1952, 42(2): 84.
[15] KE Yi-kan, DONG Hui-ru(柯以侃,董慧茹). Hangbook of Analytical Chemistry: 3B Molecular Spectral Analysis(分析化学手册. 3B. 分子光谱分析). Beijing: Chemical Industry Press(北京:化学工业出版社), 2016.
[16] DA Shi-lu, HU Bin, HE Zhi-ke, et al(达世禄,胡 斌, 何治柯,等). Analytical Chemistry(分析化学). Beijing: Higher Education Press(北京:高等教育出版社), 2016.
[17] CHEN Guo-zhen, HUANG Xian-zhi, LIU Wen-yuan, et al(陈国珍,黄贤智,刘文远,等). Ultraviolet Visible Spectrophotometry(紫外-可见光分光光度法). Beijing: Automic Press(北京:原子能出版社), 1983.
[18] Zhou Xue, Yu Jia, Wang Lin, et al. Sensors and Actuators B: Chemical, 2017, 241: 1076.
|
[1] |
LIN Hong-jian1, ZHAI Juan1*, LAI Wan-chang1, ZENG Chen-hao1, 2, ZHAO Zi-qi1, SHI Jie1, ZHOU Jin-ge1. Determination of Mn, Co, Ni in Ternary Cathode Materials With
Homologous Correction EDXRF Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3436-3444. |
[2] |
WU Shu-jia1, 2, YAO Ming-yin2, 3, ZENG Jian-hui2, HE Liang2, FU Gang-rong2, ZENG Yu-qi2, XUE Long2, 3, LIU Mu-hua2, 3, LI Jing2, 3*. Laser-Induced Breakdown Spectroscopy Detection of Cu Element in Pig Fodder by Combining Cavity-Confinement[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1770-1775. |
[3] |
ZHANG Rong1, 2, DUAN Ning1, 3, JIANG Lin-hua1, 3*, XU Fu-yuan3, JIN Wei3, LI Jian-hui1. Study on Optical Path Optimization for Direct Determination of
Spectrophotometry of High Concentration Hexavalent Chromium
Solution by Ultraviolet Visible Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1829-1837. |
[4] |
WANG Ke-qing1, 2*, WU Na1, 2, CHENG Xiao-xiang3, ZHANG Ran1, 2, LIU Wei1, 2*. Use of FTIR for the Quantitative Study of Corrosion Products of Iron
Cultural Relics[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1846-1853. |
[5] |
SI Gan-shang1, 2, LIU Jia-xiang1, LI Zhen-gang1, 2, NING Zhi-qiang1, 2, FANG Yong-hua1, 2*, CHENG Zhen1, 2, SI Bei-bei1, 2, YANG Chang-ping1, 2. Raman Signal Enhancement for Liquid Detection Using a New Sample Cell[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 712-717. |
[6] |
YANG Guo-wu1, HOU Yan-xia1, SUN Xiao-fei2, JIA Yun-hai1*, LI Xiao-jia1. Evaluation of Long-Term Stability for Non-Standard Method and
Application in Trace Element Analysis of Pure Nickel by Glow
Discharge Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 867-876. |
[7] |
ZHU Pan-pan1, 2, NIU Xiao-tao3, WANG Xue3, SI Xin1, 2, XIE Qing-gang3, CHEN Bo3, JIANG Shi-long3, JU Ning1*, ZHANG Shu-wen2*, LÜ Jia-ping2. The Stability of Room Temperature Liquid Cheese Based on Turbiscan Multiple Light Scattering Technique[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(11): 3415-3422. |
[8] |
CHEN Huan-quan1, DONG Zhong-ji2, CHEN Zhen-wei1, ZHOU Jin1, SU Jun-hao1, WANG Hao1, ZHENG Jia-jin1, 3*, YU Ke-han1, 3, WEI Wei1, 3. Study on the High Temperature Annealing Process of Thermal
Regeneration Fiber Bragg Grating[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(06): 1934-1938. |
[9] |
LI Yan-yan1, 2, LUO Hai-jun1, 2*, LUO Xia1, 2, FAN Xin-yan1, 2, QIN Rui1, 2. Detection of Craniocerebral Hematoma by Array Scanning Sensitivity Based on Near Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 392-398. |
[10] |
GAO Jian-kui1,2, LI Yi-jie3, ZHANG Qin-nan1, LIU Bing-wei1, LIU Jing-bo1, LING Dong-xiong1, LI Run-hua2, WEI Dong-shan1*. Temperature Effects on the Terahertz Spectral Characteristics of PEEK[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(11): 3347-3351. |
[11] |
LI Ming1, 2, NI Long1, WANG Meng1, 2*, ZHU Zhong-xu1, YUAN Chuan-jun1, 2, WU Jian3*. Research Progress on Evaluating the Effects of Nanomaterial-Based Development of Latent Fingerprints[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2670-2680. |
[12] |
TIAN Zhen-hua1, 2, HE Jing-xuan1, WANG Ying1, DUAN Lian3, LI Cong-hu4. Interaction and Thermal Stability of Oxidized Carboxymethyl Cellulose/Collagen Based on Two-Dimensional Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2782-2788. |
[13] |
HAN Guang1, 3, WANG Xiao-yan1, CHEN Si-qi1, WANG Hui-quan1, 3, WANG Jin-hai1, 3, ZHAO Zhe2, 3*. Research Progress on Improving the Accuracy of Near Infrared Spectroscopy Detection of Human Blood and Other Complex Solution Components[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(07): 1993-1997. |
[14] |
LIU Qing-sheng1, YANG De-wang2, GUO Jin-jia1*, YAN Ao-shuang1, ZHENG Rong-er1. Raman Spectroscopy for Gas Detection Using a Folded Near-Concentric Cavity[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(11): 3390-3393. |
[15] |
ZHAO Yi-kun1, YU Yan-bo1, SHEN Bing-hui2, YANG Yong-qin1, AI Jun-min1, YAN Yan-lu3, KANG Ding-ming1*. Influence Factors in Near-Infrared Spectrum Analysis for the Authenticity Identification of Maize Single-Kernel Varieties[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(07): 2229-2234. |
|
|
|
|