Abstract An inductively coupled plasma mass spectrometry (ICP-MS) for determination of the contents of six elements, Cd, Cr, Pb, Zn, Cu and Ni in drinking water has been developed in the present work. The operating parameters were optimized. 45Sc, 72Ge,115In and 209Bi were chosen as the internal elements and the effect of matrix, interface and fluctuation of instrument was overcome effectively. Collision/reaction technology was used to eliminate the interference of polyatomic ion. Satisfactory linearity of working curves of six elements was obtained, giving all their correlation coefficients over 0.999 7. The determination limit of the analytes were in the range of 0.70-77.0 ng·L-1. The RSD was between 0.47% and 1.69%. GBW08607 was determined and the result was in the range of the standard. Drinking water of four areas was determined, the recoveries of the sample were 92%-108%.The method is simple, quick, accurate and stable, and can be used as a reliable method to determine trace elements in drinking water.
|
Received: 2009-12-06
Accepted: 2010-03-08
|
|
Corresponding Authors:
WANG Shuo
E-mail: S.wang@tust.edu.cn
|
|
[1] HUANG Ming-li,LI Li-na,WANG Juan,et al(黄明丽,李丽娜,王 娟,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2009,29(11):3141. [2] LAI Hong-fang,LIN Cui-wu,MO Li-shu,et al(赖红芳,林翠梧,莫利书,等). Journal of Guilin University of Technology(桂林工学院学报),2009,29(3):343. [3] WANG Yu-ping,PANG Yan-hua,LI Jun,et al(王玉萍,庞艳华,李 军,等). Food Science(食品科学),2008,29(1): 231. [4] HAN Chao,CAO Xuan,YU Jing-jing,et al(韩 超,曹 煊,余晶晶,等). Chinese Journal of Spectroscopy Laboratory(光谱实验室),2009,26(3):480. [5] HU Peng-fei,MA Jing,ZOU Ding,et al(扈鹏飞,马 婧,邹 定,等). Chinese Pharmaceutical Journal(中国药学杂志),2009,44(7):548. [6] LIU Bin,YANG Bing-yu,FENG Yu-huai,et al(刘 彬,杨丙雨,冯玉怀,等). Precious Metals(贵金属),2009,30(4):63. [7] PENG Min,RUAN Xiang-yuan,LIU Chuan-sheng(彭 敏, 阮湘元, 刘传生). Environmental Study and Monitoring(环境研究与监测),2009,22(4): 13. [8] HUANG Guang-ming,DOU Yin-ping,ZHANG Jing-mei,et al(黄光明,窦银萍,张静梅,等). Rock and Mineral Analysis(岩矿测试),2008,27(1): 25. [9] WANG Yi-han,CHEN Lu(王轶晗,陈 麓). Studies of Trace Elements and Health(微量元素与健康研究),2008,25(1):44. [10] CHENG He-yong,XU Zi-gang,HUANG Xu,et al(程和勇,徐子刚,黄 旭,等). Journal of Zhejiang University·Science Edition(浙江大学学报·理科版),2009,36(6):679. [11] PENG Rong-fei,HOU Jian-rong,HUANG Cong,et al(彭荣飞,侯建荣,黄 聪,等). Chinese Journal of Health Laboratory Technology(中国卫生检验杂志),2009,19(11):2475.
|
[1] |
ZHU Zhao-zhou1*, YANG Xin-xin1, LI Jun1, HE Hui-jun2, ZHANG Zi-jing1, YAN Wen-rui1. Determination of Rare Earth Elements in High-Salt Water by ICP-MS
After Pre-Concentration Using a Chelating Resin[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(06): 1862-1866. |
[2] |
WANG Bin1, 2, ZHENG Shao-feng2, LI Wei-cai2, ZHONG Kang-hua2, GAN Jiu-lin1, YANG Zhong-min1, SONG Wu-yuan3*. Determination of Rare Earth Elements in Imported Copper Concentrate by Inductively Coupled Plasma Mass Spectrometry With High Matrix
Injection System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(06): 1822-1826. |
[3] |
ZHANG Fei1,HUA Xia2,YOU Fan1,WANG Bin3,MAO Li3*. Determination of Thallium and Its Compounds in Workplace Air by Ultrasonic Extraction-Inductively Coupled Plasma Mass Spectrometry Using No Gas Mode[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(07): 2279-2283. |
[4] |
ZHAO Ting1,2,3, CHI Hai-tao1,2,3*, LIU Yi-ren1,2,3, GAO Xia1,2,3, HUANG Zhao1,2,3, ZHANG Mei1,2,3, LI Qin-mei1,2,3. Determination of Elements in Health Food by X-Ray Fluorescence Microanalysis Combined With Inductively Coupled Plasma Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(03): 750-754. |
[5] |
ZHOU An-li1, JIANG Jin-hua1, SUN Chun-xiao2, XU Xin-zhong2, LÜ Xin-ming1,2*. Identification of Different Origins of Hetian Jade Based on Statistical Methods of Multi-Element Content[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 3174-3178. |
[6] |
ZHANG Liang-liang, WANG Chang-hua, HU Fang-fei, MO Shu-min, LI Ji-dong*. Determination of Trace Impurity Elements in Zircaloy by Ion Exchange-Inductively Coupled Plasma Mass Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(08): 2622-2628. |
[7] |
ZHAO Qian-qian1, YAN Lai-lai1,2, XIE Qing1,2, LIU Ya-qiong1,2, YANG Si-yu1, GUO Chen1, WANG Jing-yu1,2*. Effect of Zinc on the Growth and Element Content of Lactobacillus Acidophilus[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(05): 1489-1494. |
[8] |
LIAO Qin-jing, HUANG Wei-zhi, ZHANG Qian, PEI Jing-cheng*. Gemological and Spectral Characterization of Brownish Yellow Tourmaline from Mozambique[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(12): 3844-3848. |
[9] |
MAO Li, LI Rong-pei, LIU Xin, SU Hui-lan*. Quality Control to the Detection of Gross Alpha Activity in Drinking Water by Low-Background Gross Alpha/Beta Counter[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(07): 2166-2170. |
[10] |
SUN Qi-xuan, WEI Xing, LIU Xun, YANG Ting, CHEN Ming-li*, WANG Jian-hua*. Atomic Spectrometry/Elemental Mass Spectrometry in Bioanalytical Chemistry: A Review[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(05): 1340-1345. |
[11] |
LIU Rui1, Lü Yi1,2*. Metal Stable Isotope Tagging-Based Bioassay[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(05): 1346-1353. |
[12] |
LIU Liu1, 2, LIU Zhe1, YANG Yi-bing3, WANG Qin1, XU Dong-qun1*. Determination of 21 Inorganic Elements in Urine Samples by ICP-MS Using KED System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(04): 1262-1266. |
[13] |
LIANG Piao-piao1, WANG Yi-run1, WANG Ru-ming1, FAN Li-yun1, CHEN Tian-tian1, BAI Ya-hong1, YU Qian-ru1, ZHOU Shan-shan1, LIU Ying1,2*. Level and Risk Assessment of Arsenic in Muti-Media near Mining Area in Yunnan by Using Inductively Coupled Plasma Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(03): 990-996. |
[14] |
LIANG Piao-piao1, XING Yun-xin1, WEI Chun-li1, LI Yuan-yuan1, LIU Yi-ming1, HU Yu1, LIU Ying1,2*. Distribution and Assessment of Heavy Metals in the Overlying Water-Sediment-Plant-Fish System in the Wuliangsuhai Lake by Using Inductively Coupled Plasma Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(02): 652-658. |
[15] |
ZHANG Han, XUE Ai-fang, CHEN Hao, LI Sheng-qing*. Low-Density Solvent Based Dispersive Liquid-Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for the Determination of Trace Lead and Cadmium in Domestic Water[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3264-3268. |
|
|
|
|