光谱学与光谱分析 |
|
|
|
|
|
Analysis and Experimental Verification of SNR for a Far Ultraviolet Imaging Spectrograph in 115-180 nm |
YU Lei1,2, LIN Guan-yu1, QU Yi1, WANG Shu-rong1* |
1. Key Laboratory of Applied Optics,Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China 2. Graduate University of Chinese Academy of Sciences, Beijing 100049, China |
|
|
Abstract An 115-180 nm far ultraviolet limb imaging spectrograph prototype was developed for the detection of the ionosphere. For the particularity of the wavelength band in far ultraviolet, the signals accepted by the instrument are very weak. So the sensitivity and signal-noise-ratio (SNR) are two important performance parameters for the spectrograph. In the present paper, based on the signal statistical detection theory and the threshold detection theory, a method for calculation of the sensitivity and SNR has been proposed. Firstly, the probabilities of the accepted signals and system noises were analyzed. Secondly, the mathematical expressions of sensitivity and SNR of the instrument were deduced by introducing the detection probability factor and the false alarm rate factor. Based on the calculation of the sensitivity and the intensity of the particles radiation wavelengths, it was found that the sensitivity can meet the need of the detection. Finally, the SNR of the instrument were analyzed by using the method, and the coherent experiment was built to prove the results. The error of theoretic calculation and experimental results can be accepted. It indicates that the SNR analysis method is feasible.
|
Received: 2010-01-25
Accepted: 2010-05-02
|
|
Corresponding Authors:
WANG Shu-rong
E-mail: wsrong@ciomp.ac.cn
|
|
[1] Schenkel F W, Ogorzalek B S, Larrabee J C, et al. Applied Optics, 1985, 24(20): 3395. [2] Paxton L J, Christensen A B, Morrison D, et al. Proc. of SPIE, 2004, 5660: 228. [3] McCoy Robert P,Dymond Kenneth F,Fritz Gilbert G, et al. OpticalL Engineering, 1994, 33(2): 423. [4] Kalmanson Phillip C, Wilczynske Janusz, Wood Kent, et al. Proc. of SPIE, 2005, 5901: 59010Q-1. [5] Mager Rolf, Fricke Wolfgang, Burrows John,et al. Proc. SPIE, 1999, 3106: 84. [6] ZENG Qing-yong(曾庆勇). Weak Signal Detection, Second Edtion(微弱信号检测·第2版). Hangzhou:Zhejiang University Press(杭州:浙江大学出版社),2002. 156. [7] WANG Gui-hua(汪贵华). Photoelectron Device, First Edtion(光电子器件·第1版). Beijing: National Defense Industry Press(北京:国防工业出版社),2009. 101. [8] LI Min, FAN Xian-hong, NI Qi-liang, et al(李 敏, 范鲜红, 尼启良,等). Optics and Precision Engineering(光学精密工程),2008, 16(1): 1. [9] Whalen A D. Detection of Signals in Noise(First edition). New York and London:Academic Press, 1971. 145. [10] ZHOU Li-wei(周立伟). Target Detection and Identification(目标探测与识别). Beijing: Beijing Institute of Technology Press(北京: 北京理工大学出版社), 2004. 293. [11] Christensen Andrew B, Walterscheid R L, Ross M N. SPIE,1994,2266: 451. [12] Morrison Daniel, Paxton Larry, Humm Dave, et al. Proceeding of SPIE,2002, 4485: 328. [13] ZHANG Zhen-duo, WANG Shu-rong, LI Fu-tian(张振铎, 王淑荣, 李福田). Optics and Precision Engineering(光学精密工程),2009, 17(3): 482.
|
[1] |
WANG Yue1, 3, 4, CHEN Nan1, 2, 3, 4, WANG Bo-yu1, 5, LIU Tao1, 3, 4*, XIA Yang1, 2, 3, 4*. Fourier Transform Near-Infrared Spectral System Based on Laser-Driven Plasma Light Source[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(06): 1666-1673. |
[2] |
YANG Yu-qing1, CAI Jiang-hui1, 2*, YANG Hai-feng1*, ZHAO Xu-jun1, YIN Xiao-na1. LAMOST Unknown Spectral Analysis Based on Influence Space and Data Field[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1186-1191. |
[3] |
HU Li-hong1, ZHANG Jin-tong1, WANG Li-yun2, ZHOU Gang3, WANG Jiang-yong1*, XU Cong-kang1*. Optimization of Working Parameters of Glow Discharge Optical Emission Spectrometry of High Barrier Aluminum Plastic Film[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(03): 954-960. |
[4] |
LI Yan-yan1, 2, LUO Hai-jun1, 2*, LUO Xia1, 2, FAN Xin-yan1, 2, QIN Rui1, 2. Detection of Craniocerebral Hematoma by Array Scanning Sensitivity Based on Near Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 392-398. |
[5] |
LI Ming1, 2, NI Long1, WANG Meng1, 2*, ZHU Zhong-xu1, YUAN Chuan-jun1, 2, WU Jian3*. Research Progress on Evaluating the Effects of Nanomaterial-Based Development of Latent Fingerprints[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2670-2680. |
[6] |
CUI Fang-xiao1, ZHAO Yue2, MA Feng-xiang2, WU Jun1*, WANG An-jing1, LI Da-cheng1, LI Yang-yu1. Optimization of FTIR Passive Remote Sensing Signal-to-Noise Ratio and Its Application in SF6 Leak Detection in Transform Substation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1436-1440. |
[7] |
WU Zhi-feng, LI Ling, DAI Cai-hong, WANG Yan-fei, XIE Yi-hang, CHENG Qiu-tong. Temperature and Humidity Influence in Field Spectroradiometer Measurement[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1639-1643. |
[8] |
WANG Da-xin1,2, FU Li-ping1,3,4*, JIANG Fang1,3,4, JIA Nan1,2,3,4, WANG Tian-fang1,2,3,4, DOU Shuang-tuan1,2. Inversion of Ionospheric O/N2 by Using FY-3D Ionospheric Photometer Data[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(04): 1004-1010. |
[9] |
WU Zhi-feng, DAI Cai-hong, ZHAO Wei-qiang, XU Nan, LI Ling, WANG Yan-fei, LIN Yan-dong. Spectral Irradiance Responsivity Calibration Using Tunable Lasers[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(03): 853-857. |
[10] |
WANG Jing-jing1, 2, TAN Tu1*, WANG Gui-shi1, ZHU Gong-dong1, XUE Zheng-yue1, 2, LI Jun1, 2, LIU Xiao-hai1, 2, GAO Xiao-ming1, 2. Research on All-Fiber Dual-Channel Atmospheric Greenhouse Gases Laser Heterodyne Detection Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(02): 354-359. |
[11] |
SUN Ran, HAO Xiao-jian*, YANG Yan-wei, REN Long. Effect of Cavity Confinement Materials on Laser-Induced Breakdown Cu Plasma Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3801-3805. |
[12] |
LIU Qing-sheng1, YANG De-wang2, GUO Jin-jia1*, YAN Ao-shuang1, ZHENG Rong-er1. Raman Spectroscopy for Gas Detection Using a Folded Near-Concentric Cavity[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(11): 3390-3393. |
[13] |
ZHENG Guo-liang, ZHU Hong-qiu*, LI Yong-gang. Spectral Signal Denoising Algorithm Based on Improved LMS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(02): 643-649. |
[14] |
LI Zhi-wei1, 2, SHI Hai-liang1, 2, LUO Hai-yan1, 2, XIONG Wei1, 2*. Study on the Relationship Between Apodization Function and Signal-to-Noise Ratio of Hyperspectral Spatial Interferogram[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(01): 29-33. |
[15] |
FU Li-ping1,2, JIA Nan1, 2,3, HU Xiu-qing4*, MAO Tian4, JIANG Fang1,2, WANG Yun-gang4, PENG Ru-yi1,2, WANG Tian-fang1,2,3, WANG Da-xin3, DOU Shuang-tuan3. Research Progress on On-Orbit Calibration Technology for Far Ultraviolet Payload[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(12): 3673-3680. |
|
|
|
|