光谱学与光谱分析 |
|
|
|
|
|
Research on the Background Subtraction Method for X-Ray Fluorescence Spectrum with X-Ray Tube Excitation |
GUO Cheng1, LAI Wan-chang1*, HU Yuan2, HUANG Jin-chu1, ZHAI Juan1, CHENG Feng1, WANG Guang-xi1, ZENG Guo-qiang1, ZHANG Qing-xian1 |
1. The College of Nuclear Technology and Automation Engineering, Chengdu University of Technology,Chengdu 610059,China 2. College of Earth Sciences, Chengdu University of Technology,Chengdu 610059,China |
|
|
Abstract X-ray tube is the most commonly used equipment in X-ray fluorescence spectrum analysis as excitation source whose primary spectrum has become a major source of the background of X-ray fluorescence spectrum. Background subtraction should go before further analysis of this spectrum. The accuracy of the estimation of the background directly affect the results of subsequent processing steps. In this paper, the tube excitation component of X fluorescence spectrum is analyzed with an estimation method of background intensity against their background characteristics, and structuring theoretical spectral lines based on the measured spectral lines in order to evaluate the effect of spectral processing algorithms. The method utilizes the measured X-ray fluorescence spectrum which does not contain the characteristic peak of the spectrum, In order to estimate the composition of the original spectrum of the X-ray tube. It uses the spectrum that contains the continuous background for interpolating the entire measured spectrum, thereby avoiding overlapping the spectral characteristic peaks or improperly estimating full width at half maximum. This paper compared SNIP, Fourier transform method and the background subtraction method using the measured spectral lines. Using this method to estimate the background is closer to the theoretical background. The results showe that the method for X-ray fluorescence spectrum by X-ray tube excitation is accurate in this article, this method can be used to deduct continuous background, and good applied effectiveness has been achieved in the background subtraction of the actually measured X-ray fluorescence spectrometry.
|
Received: 2015-06-11
Accepted: 2015-10-15
|
|
Corresponding Authors:
LAI Wan-chang
E-mail: lwchang@cdut.edu.cn
|
|
[1] ZHANG Qing-xian,GE Liang-quan,GU Yi,et al(张庆贤,葛良全,谷 懿,等). Nuclear Techniques(核技术),2011,34(8):569. [2] Banduch P,Morh M,Kritiak J. Nuclear Instruments and Methods in Physics Research Section A,1997,384(2):506. [3] Morh M. Nuclear Instruments and Methods in Physics Research Section A,2007,581(3):821. [4] ZHANG Qing-xian,GE Liang-quan,ZENG Guo-qiang,et al(张庆贤,葛良全,曾国强,等). Atomic Energy Science and Technology(原子能科学技术),2011,45(10):1258. [5] Morh M. Nuclear Instruments and Methods in Physics Research Section A,2006,559(1):119. [6] WU He-xi,LIU Qing-cheng,YANG Bo,et al(吴和喜,刘庆成,杨 波,等). Nuclear Techniques(核技术),2010,33(7):513. [7] Prospathopoulos A,Tsabaris C. Applied Radiation and Isotopes,2011,69(10):1546. [8] Casanovas R,Morant J J,Salvadó M. Radiation Measurements,2012,47(8):1350. [9] Kramers H A. Philosophical Magazine Series 6,1923,46(275):836. [10] GU Yi,XIONG Sheng-qing,GE Liang-quan,et al(谷 懿,熊盛青,葛良全,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2014,34(1): 252. [11] Walter S,Burkhard B,Birgit K,et al. X-Ray Spectrometry,1993,22(4):317. [12] JI Xin-ming,WANG Jian-ye,JIA Wen-hong,et al(纪新明,王建业,贾文红,等). Acta Optica Sinica(光学学报),2006,26(4):634. [13] JI Ang,ZHUO Shang-jun,LI Guo-hui(吉 昂,卓尚军,李国会). Energy Dispersive X-Ray Fluorescence Spectrometry(能量色散X射线荧光光谱). Beijing:Science Press(北京:科学出版社),2011. [14] ZHUO Shang-jun,TAO Guang-yi,HAN Xiao-yuan(卓尚军,陶光仪,韩小元). Fundamental Parameter Method of X-Ray Fluorescence Spectrometry(X射线荧光光谱的基本参数法). Shanghai:Shanghai Scientific and Technical Publishers(上海:上海科学技术出版社),2010.
|
[1] |
ZENG Guo-qiang, GE Liang-quan, LUO Yao-yao, ZHANG Qing-xian, CHENG Feng, WANG Guang-xi . Research on the Peak Search Method Based on Improved Simulated Annealing Model for X-Ray Fluorescence Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(09): 2583-2585. |
[2] |
LI Fei, GE Liang-quan*, LUO Yao-yao, ZHANG Qing-xian, GU Yi . The Application of Improved GMDH Network to the Portable X-Ray Fluorescence Analyzer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(06): 1711-1713. |
[3] |
LI Fei, GE Liang-quan*, ZHANG Qing-xian, GU Yi, WAN Zhi-xiong, LI Wang-yan . Research on the Application of Improved M-P Neural Network to the Determination of Lead and Zinc Ore Element Contents by Energy Disperse X-Ray Fluorescence Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(05): 1410-1412. |
[4] |
CHU Bin-bin1,2, LUO Li-qiang1*. EDXRF Analysis of Soil Heavy Metals on Lead-Zinc Orefield [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30(03): 825-828. |
[5] |
ZHOU Shao-hua1*,FU Lue1,LEUNG Bao-liu2. Study on the Cultural Relic Material Site and Period by EDXRF[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28(05): 1181-1185. |
|
|
|
|