光谱学与光谱分析 |
|
|
|
|
|
Quenched Fluorescein: A Reference Dye for Instrument Response Function of TCSPC |
PAN Hai-feng1, DING Jing-xin1, LIANG Rong-rong1, TAO Zhan-dong1, LIU Meng-wei1, ZHANG San-jun1*, XU Jian-hua1 |
State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China |
|
|
Abstract Measuring the instrument response function (IRF) and fitting by reconvolution algorithms are routines to improve time resolution in fluorescence lifetime measurements. Iodide ions were successfully used to quench the fluorescence of fluorescein in this study. By systematically adding saturated NaI water solution in basic fluorescein solution, the lifetimes of fluorescein were reduced from 4 ns to 24 ps. The quenched lifetime of fluorescein obtained from the analysis of Time-Correlated Single Photon Counting (TCSPC) measurement agrees well with that from femtosecond frequency up-conversion measurement. In time resolved excitation spectra measurements, the IRF should be measured at various detection wavelengths providing scattring materials are used. This study could not only reduce the complexity of IRF measurement, but also avoid the existing color effect in system. This study should have wide applications in time resolved fluorescence spectroscopy and fluorescence lifetime imaging.
|
Received: 2013-07-18
Accepted: 2013-10-15
|
|
Corresponding Authors:
ZHANG San-jun
E-mail: sjzhang@phy.ecnu.edu.cn
|
|
[1] Luchowshi R, Sabnis S,Szabelski M, et al. J. Lumin., 2010, 130(12): 2446. [2] Zheng H, Zhan X Q, Bian Q N, et al. Chem. Commun., 2013, 49(5): 429. [3] Holcova V, Sima J, Dusek J. Cent. Eur. J. Chem., 2013, 11(2): 200. [4] Draxler S, Lippitsch M E. Sens. Actuators B, 1993, 11: 421. [5] Hormozi-Nezhad M R, Bagheri H, Bohloul A, et al. J. Lumin., 2013, 134: 874. [6] Liu L, Yang K S, Zhang X Y, et al. J. Rare Earth, 2012, 30(11): 1092. [7] Lawrence W G, VanMarter T A, Nowlin M L, et al. J. Chem. Phys., 1997, 106(1): 127. [8] Lakowicz J R. Principles of Fluorescence Spectroscopy. 3 ed. Kluwer Academic/Plenum Publishers, 2006. [9] Hanley Q S, Subramaniam V, Arndt-Jovin D J, et al. Cytometry, 2001, 43(4): 248. [10] Szabelski M, Luchowski R, Gryczynski Z, et al. Chem. Phys. Lett., 2009, 471(1-3): 153. [11] Becker W, Bergmann A, Hink M A, et al. Microsc. Res. Techniq., 2004, 63(1): 58. [12] Padilla-Parra S, Auduge N, Coppey-Moisan M, et al. Microsc. Res. Techniq., 2011, 74(8): 788. [13] Ruan P Q, Gao F, Yang F, et al. Chin. Opt. Lett., 2010, 8(8): 787. [14] Huang Z X, Ji D M, Xia A D. Colloid Surface A, 2005, 257-258: 203. [15] Nikitin A V, Davidchack R L, Armstrong T P. Nucl. Instrum. Meth. A, 1998, 411(1): 159. [16] Xu J H, Knutson J R. Method Enzymol., 2008, 450: 159. |
[1] |
ZHOU Zi-hao1, YANG Fan2, 3, LI Dong1, WANG Jian-ping2, 3, XU Jian-hua1*. pH Dependent Time-Resolved Fluorescence Spectra of ZnSe Quantum Dots Based on Glutathione Ligands[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3178-3183. |
[2] |
YIN Wen-zhi1,2,3, WANG Ting-yu1,3,ZHU Tuo1, 3, MA Chao-qun1, 3, GU Jiao1, 3, ZHU Chun1, 3, LI Lei1, 3, CHEN Guo-qing1, 3*. The Study on Fluorescence Spectral Characteristics of Three Brands of Milk[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(02): 535-539. |
[3] |
MIAO Quan-long1, DAI Lei1, LI Bai-cheng1, ZHAO Tian-qi1, LIANG Kun1, 2, YANG Ru1, 2, HAN De-jun1,2*. Time-Resolved Raman Scattering Measurement Based on SiPM and TCMPC Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(05): 1444-1450. |
[4] |
ZHANG Xiao-he1, 2, MA Chao-qun1, 2*, CHEN Guo-qing1, 2, LIU Huai-bo1, 2, ZHU Chun1, 2, SONG Xin-shu1, 2, ZHU Cong-hai1, 2. The Fluorescnece Lifetime and Quantum Chemistry Calculation of Ethyl Caproate and Ethyl Acetate[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(02): 502-505. |
[5] |
Kariyemu·AIHAITI1, Mirzat·MAIMAITI2, Arkin·IBURAIM1, 3*. Study Comparative Light Intensity of Laser Light Source-Online Fluorescence Spectrum Detection[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(01): 134-138. |
[6] |
HUO Yan-feng1, 2, DUAN Min-zheng2, JIANG Zhe2*, MEI Lin3, JIANG Yin3, MAO Xia4 . Factors Analysis for CO2 Retrieval from the Ground-Based Hyperspectral Measurements in the Short Wave Infrared [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(09): 2500-2504. |
[7] |
HOU Jun-feng1, LI Xin-xia2, SHEN Xue-ru1, Miliban Huojia1, GUAN Ming1* . Determination of H2S in Rat Intestinal Perfusion Solution Based on Fluorescence Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(08): 2217-2220. |
[8] |
ZHU Yuan-qiang1, 2, ZHANG Li2, GUO Jian-chun1 . Theoretical Investigation on the Structure and Vibration Spectrum of D-Luciferin[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(09): 2453-2459. |
[9] |
JIANG Li-lin1,2, SONG Yun-fei1, YANG Zhen-ling1, HE Xing1, LIU Wei-long1, YU Guo-yang1, WANG Yang1, YANG Yan-qiang1*. Research on the Spectral Properties of the Rhodamine 101 Dye [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(05): 1348-1351. |
[10] |
LI Yun-hui1, DI Yan-qing1, YANG Xiu-yun1, PAN Li-hua2*, LI Jun-ling2, WANG Yun-lei2, LI Hai-yan1, CHANG Yu2, LIU Wen-yu1 . Study on Method of Time-Resolved Fluorescence Spectra for Rare Fluorescence Chelate [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30(09): 2475-2478. |
[11] |
OUYANG Jian-ming,CHANG Sheng-li,SHAO Fu-qiu. Experimental Research on Remote Sensing Spectrometer’s Instrument Response Function[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(08): 2295-2297. |
[12] |
LIU Yi-ming,XUAN Chun-sheng,LI Wen-ying*,FENG Jie. Study of Cefadroxil and Cephradine Charge Transfer Process by Fluorescence Quenching Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(02): 441-445. |
[13] |
LIU Zhi-ming,GAO Min-guang,LIU Wen-qing,LU Yi-huai,ZHANG Tian-shu,XU Liang,WEI Xiu-li. The Study of Instrument Response Function of FTIR Detectors[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28(08): 1786-1789. |
[14] |
LIU Bao-sheng,ZHANG Yan-qing,WANG Yun-ke, Lǖ Yun-kai. Study on the Mechanism of Energy Transfer between Fluorescein Sodium and Tetrabromofluorescein Sodium in Micelles of Cationic Surface Active Agent[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28(07): 1600-1602. |
[15] |
GUO Yan-li,YAN Hong-tao,PEI Ruo-hui. Quenching Effect of Gold Nanoparticles for Fluorescein Sodium[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28(02): 380-383. |
|
|
|
|