Abstract Imaging fiber bundles were introduced to dispersion imaging spectrometer and substituted for slit, connecting the telescope and spectrometer to yield the imaging fiber-optic spectrometer. It is a double sampling system, the misalignment between image of optical fiber and detector pixel has arisen because of the spectrum distortion of spectrometer, which affected the second sampling process, and the modulation transfer function (MTF) therefore degraded. Optical transfer function of sampling process was derived from line spread function. The effect of spectrum distortion on system MTF was analyzed, and a model evaluating the MTF of imaging fiber-optic spectrometer was developed. Compared to the computation model of MTF of slit imaging spectrometer, a MTF item of sampling by optical fiber and a MTF item of misalignment arising from spectrum distortion were added in this model. Employing this, the MTF of an airborne imaging fiber-optic spectrometer for visible near infrared band was evaluated. The approach ro deriving and developing the MTF model has a reference signification for the computation of MTF of double sampling system, which can direct the design of imaging fiber-optic spectrometer also.
|
Received: 2010-12-10
Accepted: 2011-04-08
|
|
Corresponding Authors:
WANG Jing
E-mail: wangjingYX1@sina.com
|
|
[1] ZHENG Bao-hua, CHENG De-fu, ZHENG Zhi-zhong, et al(郑宝华,程德福,郑志忠,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2010, 30(5): 1417. [2] ZHANG Yong, ZHAO Da-zun(张 勇,赵达尊). Journal of Beijing Institute of Technology(北京理工大学学报),1997, 17(4): 151. [3] CHEN Zi-kuan, ZHAI Hong-chen, MU Guo-guang(陈自宽,翟宏琛,母国光). Optical Technology(光学技术), 1998, 1(1): 57. [4] Renee D. J. Opt. Soc. Am.,1964, 54(7): 907. |
[1] |
LI Xin-quan1, 2,ZHANG Jun-qiang1, 3*,WU Cong-jun1,MA Jian1, 2,LU Tian-jiao1, 2,YANG Bin3. Optical Design of Airborne Large Field of View Wide Band Polarization Spectral Imaging System Based on PSIM[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 250-257. |
[2] |
LI Ming, QIN Kai*, ZHAO Ning-bo, TIAN Feng, ZHAO Ying-jun. Study on the Relationship Between Black Soil Emissivity Spectrum and Total Potassium Content Based on TASI Thermal Infrared Data[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(09): 2862-2868. |
[3] |
LIU Jia-nan1, 2*, CUI Ji-cheng1, YIN Lu1, 2, SUN Ci1, CHEN Jian-jun1, 2, ZHANG Rui1, 2, LIU Jian-li1, 2. Analysis and Design of Pre-Imaging System of Integral Field Imaging Spectrometer Based on Lenslet Array[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3269-3272. |
[4] |
ZHAO Shou-jiang1, YANG Bin1, JIAO Jian-nan2, YANG Peng1, WU Tai-xia3*, WANG Xue-qi1, YAN Lei1*. Using a Polarization Method to Reduce the Vegetation Inversion Error Caused by Strong or Weak Reflection Intensity[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3315-3320. |
[5] |
ZHANG Quan1, 2, HUANG Shu-hua1*, TIAN Yu-ze1, 2, LU Yue-lin1, 2, ZHAO Min-jie1, ZHOU Hai-jin1, ZHAO Xin1, WANG Yu1, SI Fu-qi1. Noise Analysis and Processing Method of Environment Monitoring Instrument[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(09): 2976-2981. |
[6] |
LIU Xiang-lei1,2, LIU Yang-yang1*, FANG Yu1, PEI Lin-lin1, Lü Qun-bo1. Optical Design of Large Relief Large Relative Apertureand High Resolution Modified Dyson Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3908-3912. |
[7] |
GAO Jian-hua1,2, LIANG Jing-qiu1, Lü Jin-guang1*, LIANG Zhong-zhu1, QIN Yu-xin1, WANG Wei-biao1. A Stepped Mirror Based Temporally and Spatially Modulated Imaging Fourier Transform Spectrometer: Principle and Data Processing[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3932-3939. |
[8] |
LI Shi-wei1,2, WANG Zhao-ba1,2, ZHANG Rui1,2,WANG Zhi-bin1,2,3. Spectral Measurements Based on Difference Frequency Modulation of Two PEMs Modulators[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(09): 2966-2973. |
[9] |
ZHENG Zhi-zhong1,2, YANG Zhong1*, XIU Lian-cun2, DONG Jin-xin2, CHEN Chun-xia2, GAO Yang2, YU Zheng-kui2. Design of a SWIR Offner Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2267-2272. |
[10] |
MAO Jing-hua1, 2, WANG Yong-mei1,2*, SHI En-tao1, ZHANG Zhong-mou1, JIANG Fang1. Study on the Slitfunction Test Method Based on Hyperspectral Imaging Instrument[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(04): 1286-1290. |
[11] |
PEI Lin-lin1, XIANGLI Bin1, 2, LIU Yang-yang2*, Lü Qun-bo2, SHAO Xiao-peng1 . The Snapshot Imaging Spectrometer with Image Replication Based on Wallaston Prism[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(12): 4105-4112. |
[12] |
LIU Yu-juan1, WANG Cheng-ming1, LIN Jun1*, CUI Ji-cheng2, ZHANG Tian-yu1*, ZHONG Zhi-cheng1* . Optimal Design of Light Folding Imaging Spectrometer Based on Dyson Concentric System [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(07): 2287-2290. |
[13] |
LIU Bing1, 2, LIU Ying1, ZHANG Xiao-long3, LI Can1, WANG Jian1, LI Chun1*, SUN Qiang1. Study on Coaxial Linear Dispersion Triplet Prisms of Wide Spectral Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1543-1548. |
[14] |
Lü Jin-guang1, LIANG Jing-qiu1, LIANG Zhong-zhu1*, TIAN Chao1, 2, QIN Yu-xin1. Analysis and Design of Interference Imaging System in Fourier Transform Imaging Spectrometer Based on Multi-Micro-Mirror[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1554-1559. |
[15] |
XIE Pei-yue1, 2, YANG Jian-feng1, XUE Bin1*, Lü Juan1, HE Ying-hong1, LI Ting1, MA Xiao-long1 . Research on an Equal Wavelength Spectrum Reconstruction Method of Interference Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(03): 848-852. |
|
|
|
|