光谱学与光谱分析 |
|
|
|
|
|
Absorption Line Intensities of Phosphine in the Regions 1 950-2 480 cm-1 and 3 280-3 580 cm-1 Studied by Fourier-Transform Spectroscopy |
WANG Le, CHEN Ping, CHENG Guo-sheng, DING Yun, HU Shui-ming* |
Laboratory of Bond Selective Chemistry, Department of Chemical Physics, University of Science and Technology of China, Hefei 230026, China |
|
|
Abstract The data of line intensities of the fundamental and low overtone absorption bands of phosphine are the basic reference data for the applications in quantative analysis and astronomy.The method of high-resolution Fourier-transform spectroscopy study on the absorption line intensities is discussed.With a series of measurement and fitting the line profiles, altogether 1 760 absorption lines intensities of phosphine were obtained, corresponding to five bands in the 1 950-2 480 cm-1region and four bands in the 3 280-3 580cm-1 region.The accuracy of the line intensities was estimated to be ±6%.
|
Received: 2004-06-22
Accepted: 2004-12-23
|
|
Corresponding Authors:
HU Shui-ming
|
|
Cite this article: |
WANG Le,CHEN Ping,CHENG Guo-sheng, et al. Absorption Line Intensities of Phosphine in the Regions 1 950-2 480 cm-1 and 3 280-3 580 cm-1 Studied by Fourier-Transform Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(08): 1221-1226.
|
|
|
|
URL: |
https://www.gpxygpfx.com/EN/Y2005/V25/I08/1221 |
[1] Tokunaga A T, Knacke R F, Ridgway S T, et al.Astrophys.J.1979, 232: 603. [2] Ulenikov O N, Bekhtereva E S, Kozinskaia V A, et al.J.Mol.Spectrosc., 2002, 215: 295. [3] Ulenikov O N, Bekhtereva E S, Kozinskaia V A, et al.J.Quan.Spectrosc.Rad.Trans., 2004, 83: 599. [4] Rothman L S, Barbe A, Chris-Benner D, et al.J.Quant.Spectrosc.Radiat.Trans., 2003, 82: 5. [5] Dana V, Mandin J-Y, Allout M Y, et al.J.Quant.Spectrosc.Radiat.Trans., 1996, 56: 119. [6] Mandin J-Y, Dana V, Claveau C.J.Quant.Spectrosc.Radiat.Trans., 2000, 67: 429. [7] Ma Q, Tipping R H, Boulet C.J.Quant.Spectrosc.Radiat.Trans., 1998, 59: 245. [8] Ma Q, Tipping R H.J.Chem.Phys., 2002, 116: 1402.
|
[1] |
ZHU Xiao-ming1, 2, 3, BAI Xian-yong1, 2, 3*, LIN Jia-ben1, 2, DUAN Wei1, 2, ZHANG Zhi-yong1, 2, FENG Zhi-wei1, 2, DENG Yuan-yong1, 2, YANG Xiao1, 2, HUANG Wei1, 2, 3, HU Xing1, 2, 3. Design and Realization of High-Speed Acquisition System for Two Dimensional Fourier Transform Solar Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(12): 3842-3850. |
[2] |
WANG Yue1, 3, 4, CHEN Nan1, 2, 3, 4, WANG Bo-yu1, 5, LIU Tao1, 3, 4*, XIA Yang1, 2, 3, 4*. Fourier Transform Near-Infrared Spectral System Based on Laser-Driven Plasma Light Source[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(06): 1666-1673. |
[3] |
CHEN Fang, GAO Chao, BAI Jie. Thickness Matching Design Between Splitter and Compensatorfor High Spectral Resolution Fourier Transform Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3941-3945. |
[4] |
TIAN Yuan1, SUN You-wen1*, XIE Pin-hua1,2, LIU Cheng2, LIU Wen-qing1,2, LIU Jian-guo1,2, LI Ang1, HU Ren-zhi1, WANG Wei1, ZENG Yi1. Quality Optimization Method for Ambient CO2 Inversion of High Resolution Fourier Transform Infrared Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(01): 48-53. |
[5] |
ZHAI Yang1, 2, XIAO Dong1, 2, LI Bo1, 2, ZHU Ri-hong3 . A Research on Filed-of-View (FOV) Widening and Thermal-Phase-Drift (TPD) Compensating Technology Applied in a Polarized Interference Imaging Spectrometer (PIIS)[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(11): 3720-3725. |
[6] |
ZHAO Bao-wei1, XIANGLI Bin1, 2, CAI Qi-sheng3, Lü Qun-bo2*, ZHOU Jin-song2 . Fourier Transform Spectrometer Based on Rotating Parallel-Mirror-Pair [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(11): 3209-3213. |
[7] |
ZHANG Min-juan3, WANG Zhi-bin1, 2, 3, LI Xiao3, LI Jin-hua3, WANG Yan-chao3 . The Stability and Measuring Technology of the Maximum Optical Path Difference of Photo-Elastic Modulator Interferograms [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(05): 1436-1439. |
[8] |
WANG Ning, GONG Tian-cheng, CHEN Jian-jun, LI Yang, YANG Yi-ning, ZHU Yong, ZHANG Jie, CHEN Wei-min . A Phase Error Correction Method for the New Fourier Transforms Spectrometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(11): 2934-2937. |
[9] |
ZHANG Min-juan3, WANG Zhao-ba1, 2, WANG Zhi-bin3, LI Xiao3, LI Shi-wei3, LI Jin-hua3 . The Technology of Fast Spectral Reconstruction in the Longer Optical Path Difference PEM-FTS [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(07): 2010-2014. |
[10] |
CHEN You-hua1, WANG Zhao-ba1,2, WANG Zhi-bin1,2, WANG Yan-chao1, LI Yong-shuai1, ZHANG Yu-han1 . The Study of Photo-Elastic Modulator-Based Fourier Transform Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(06): 1502-1505. |
[11] |
Lü Jin-guang1, 2, LIANG Jing-qiu1*, LIANG Zhong-zhu1, QIN Yu-xin1, TIAN Chao1, 2 . Study on Transmission Efficiency of Interference System in Spatially Modulated Fourier Transform Spectrometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(03): 850-854. |
[12] |
Lü Jin-guang1, 2, LIANG Jing-qiu1*, LIANG Zhong-zhu1 . Study on Spectrum Inversion of Spatially Modulated Fourier Transform Spectrometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(06): 1694-1699. |
[13] |
Lü Jin-guang1,2, LIANG Jing-qiu1*, LIANG Zhong-zhu1, FU Jian-guo1,2. Study on Uniformity of Optical Field in Static Fourier Transform Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(01): 259-263. |
[14] |
Lü Jin-guang1,2, LIANG Zhong-zhu1, FU Jian-guo1,2, LIANG Jing-qiu1* . Analysis of Collimation Error in Fourier Transform Infrared Spectrometer Based on Step Mirrors[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(10): 2865-2869. |
[15] |
WANG Xin-quan1,3, XIANGLI Bin2, HUANG Min2, HU Liang1*, JING Juan-juan1,3 . Study and Simulation of the Intensity Modulation-Fourier Transform Spectropolarimeter [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(07): 1980-1984. |
|
|
|
|