光谱学与光谱分析 |
|
|
|
|
|
Research on SCB Discharge Behavior with Atomic Emission Spectroscopy |
ZHANG Lin1, FENG Hong-yan1, ZHU Shun-guan1, WU Rong2, ZHANG Wen-chao1 |
1. School of Chemical Engineering, Nanjing University of Science & Technology, Nanjing 210094, China 2. Department of Chemistry, Chaohu University, Chaohu 238000, China |
|
|
Abstract Semiconductor bridge (SCB) was utilized to ignite energetic materials with thin film discharge and characterized of low input energy, high safety and logic control possibility. SCB discharge was diagnosticated with atomic emission spectroscopy. Firstly, discharge temperature was acquired with copper atom spectral lines 510.5 and 521.8 nm, and electron density was calculated with silicon atom spectral line 390.5 nm and corresponding ion line 413.0 nm. As for resistance 1.0 Ω of SCB with the discharge voltage of 20 V and capacity of 47 μF, its discharge temperature was about 2 500-4 300 K and electron density 1016 cm-3. Meanwhile, the temperature and density Vs time distributions were acquired simultaneously. And then with the diagnosis results, the discharge behaviors of two sorts of SCB were judged according to plasma space-dimension and time-dimension restrictions. This research set up an efficient technique for the diagnosis of transient small-size discharge behavior and provided instructions for the design of SCB and discharge condition.
|
Received: 2009-02-10
Accepted: 2009-05-12
|
|
Corresponding Authors:
ZHANG Lin
E-mail: l_njust@yahoo.com.cn;waterlikelin@163.com
|
|
[1] Rossi C, Esteve D. Sensors and Actuators A: Physical, 2005, 120(3): 297. [2] Park M, et al. Sensors and Actuator A, 2004, 115(1), 104. [3] Richard A, Beyer R A. IEEE Transactions on Magnetics, 2003, 39(1): 207. [4] Lee K N, Park M I, Choi S H P, et al. Sens. Actuators A, 2002, 96: 252. [5] Kim J U, Park C O, Park M, et al. Physics Letters A, 2002, 305(2): 413. [6] Spatenka P, Vlcek J, Blazek J. Vacuum, 1999, 55(2): 165. [7] Rego C A, Tsang R S. J. Appl. Phys., 1996, 79(2): 7264. [8] Benson D A, Larsen M E, Renfund A M,et al. J. Appl. Phys., 1987, 62(5): 1622. [9] Kim J, Nam K S, Jungling K C. IEEE Trans. Electron Devices, 1997, 44(6): 1022. [10] Aguilera J A, Aragón C. Spectrochimica Acta Part B: Atomic Spectroscopy, 2004, 59(12): 1861. [11] ZHAO Hua-qiao(赵化侨). Plasma Chemistry and Process(等离子体化学与工艺). Beijing:Science Press(北京:科学出版社),1990. 15. [12] Demchenko V V, Hussein A M. Physics Letters A, 1973, 42(5): 379.
|
[1] |
LIU Pan1, 2, 3, DU Mi-fang1*, LI Bin1, LI Jing-bin1, ZENG Lei1, LIU Guo-yuan1, ZHANG Xin-yao1, 4, ZHA Xiao-qin1, 4. Determination of Trace Tellurium Content in Aluminium Alloy by
Inductively Coupled Plasma-Atomic Emission Spectrometry Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(10): 3125-3131. |
[2] |
LI Zheng-kai1, CHEN Lei1*, YANG Cong1, SONG Peng2, 3, ZENG Wen1, LIU Ai-guo1, PANG Jun-yi1. A Study on Emission Spectral Diagnosis of Ar/CH4 Plasma Jet[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1398-1403. |
[3] |
ZHAI Yu-xin1, CHEN Jun1, LI Ti1*, LIU Ji-yan2, WANG Xie-yi1, CHENG Chao1, LIU Cheng-mei1 . Determination of Mineral Elements in Choerospondias Axillaris and Its Extractives by ICP-AES [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(04): 1052-1055. |
[4] |
HAO Zhi-hong, YAO Jian-zhen, TANG Rui-ling, ZHANG Xue-mei, LI Wen-ge, ZHANG Qin* . Study on the Method for the Determination of Trace Boron, Molybdenum, Silver, Tin and Lead in Geochemical Samples by Direct Current Arc Full Spectrum Direct Reading Atomic Emission Spectroscopy (DC-Arc-AES)[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(02): 527-533. |
[5] |
LI Hua1, LIU Jing1, 2, FU Mei-hong1, KANG Chen1, FANG Jing1, YANG Bin1*. Analysis of Dissolution Characteristics and Content of Metal Elements in Scutellaria Baicalensis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(08): 2264-2267. |
[6] |
JIAN Zai-you1, 2,WANG Wen-quan2*,LI Wei-dong2,MENG Li1,XU Gui-fang1,WANG Qiu-ling2,WANG Dan2 . Determination of Mineral Elements Utilization of Paeonia lactiflora Pall by ICP-AES [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(11): 3105-3111. |
[7] |
GE Yu-wei1, XIAO Li-mei2, SUO Jin-ling3, WANG Cheng4*, HU Xiao-min5, ZHAO Shu-yun6 . Determination of Gold in Copper Matte and Sintered Copper Material [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(05): 1423-1427. |
[8] |
NING Peng-bo1, GONG Chun-mei2, ZHANG Yan-ming1*, GUO Kang-kang1 . Analysis of Rare Earth Elements in Pu’er Tea of Yunnan by ICP-AES [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30(10): 2830-2833. |
[9] |
ZHANG Zu-lei, LI Chun-xiang, YAN Yong-sheng*, GAO Jie, PAN Jian-ming, ZHANG Xiao-jie . Analysis of Properties of Cadmium Adsorption onto Whisker Surface Ion-Imprinted Polymer by Inductively Coupled Plasma Atomic Emission Spectrometry [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30(03): 792-796. |
[10] |
WAN Jie, LIU Cheng-mei*, LIU Wei, TU Zong-cai, LI Chu, ZHANG Wen-qin . Determination of Mineral Elements in Soybean from Different Producing Areas by ICP-AES [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30(02): 543-545. |
[11] |
LIU Hong-gao1,WANG Yuan-zhong2. Separation/Preconcentration of Trace Rare Earth Elements in Tricholoma Giganteum by Micro-Column with Nanometer Al2O3 and Their Determination by ICP-AES [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30(01): 259-261. |
[12] |
ZHANG Yu-ling1,2,WANG Song-jun2*,WANG Pu-jun3, CAI Yu1,4 . Study of Microelements in Plant’s Ash and Environmental Soil by Microwave Digestion ICP-AES[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(08): 2240-2243. |
[13] |
ZENG Ya-wen1, 3, WANG Lu-xiang2, PU Xiao-ying1, DU Juan1, YANG Shu-ming1, LIU Jia-fu2, TAI Li-mei1, 3 . The Zonal Characterization of Elemental Concentrations in Brown Rice of Core Collection for Rice Landrace in Yunnan Province by ICP-AES [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(06): 1691-1695. |
[14] |
HE Jin-zhe,KUI Xiao-yun,YANG Kai, SHAO Pin, SUN Pei-long* . Analysis of Twenty Trace Elements in Ling Zhi by ICP-AES[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(05): 1409-1412. |
[15] |
XU Wan-zhen, LI Chun-xiang, LIU Ai-qin, YAN Yong-sheng*. ICP-AES Determination of Cu2+,Pb2+ and Cd2+ with Adsorption Behavior of Potassium Hexatitanate Whisker[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(03): 801-804. |
|
|
|
|