|
|
|
|
|
|
Determination of Thallium and Its Compounds in Workplace Air by Ultrasonic Extraction-Inductively Coupled Plasma Mass Spectrometry Using No Gas Mode |
ZHANG Fei1,HUA Xia2,YOU Fan1,WANG Bin3,MAO Li3* |
1. Sichuan Center for Disease Control and Prevention, Chengdu 610041, China
2. Sichuan Center for Food and Drug Evaluation, Inspection & Monitoring, Chengdu 610017, China
3. School of Public Health, Chengdu Medical College, Chengdu 610500, China |
|
|
Abstract Thallium (Tl), an extremely toxic metal element, was mainly used to manufacture semiconductors, electronic equipment, pesticide, and rodenticide. The determination of thallium and its compounds in workplace air was of great significance to ensure the health of the occupational people because they posed a potential threat to their physical health. Although trace amounts of thallium were more toxic than other toxic metals in the workplace air, little research was done. At present, atomic absorption spectrometry (AAS) was the main method for thallium assay in workplace air, but this method had some shortcomings. Therefore, we proposed a new method for the determination of thallium and its compounds in workplace air by ultrasonic extraction-inductively coupled plasma mass spectrometry (ICP-MS) using No Gas mode. At the sampling point, the short sampling workplace air was sampled by a microporous membrane with an aperture of 0.8 μm according to GBZ 159—2004 method. The effect of ultrasonic extraction conditions on the result was investigated, and the interference and elimination of mass spectrometry were analyzed. The optimized experimental conditions were 3% HNO3 for ultrasonic extraction of the filter membrane samples for 10 min at room temperature and No Gas mode for ICP-MS analysis. Under the optimal conditions, good linearity was obtained in the range of 0.087 to 80 ng·mL-1, with linear calibration curves of Y=0.009 2X-0.001 8 (R=0.999 9). The detection limit (LOD) was 0.026 ng·mL-1. When the sampling volume was 75 L, the minimum detected concentration was 0.001 7 g·m-3, and the minimum quantitative concentration was 0.005 7 g·m-3. The precision and accuracy of the method were verified by the quality control samples (thallium quality control samples ZK147 and ZK148 in the filter membrane). The results showed no significant difference between the measured value and the reference value, and the relative standard deviation (RSDs) was 0.77% and 0.86%. Interference analysis of the new method was carried out by adding standard method (common interfering elements with 3 times the thallium content in membranes), and the recovery rate was between 97.2% and 106.7%, indicating that the method had strong anti-interference ability. Comparing with the national standard method of “Determination of toxic substances in workplace air-Part 25: Thallium and its compounds” GBZ/T 300.25—2017 solvent elution-graphite furnace atomic absorption spectrometry (GFAAS), the results of 10 samples were basically consistent. And the proposed method exhibited a simpler operation, lower detection limit, wider linear range and higher accuracy, which met the needs of accurate, rapid, trace and high-throughput determination of thallium and its compounds in samples. The new method is expected to be a new method for the determination of thallium and its compounds in workplace air and can provide reference and basis for health monitoring of specific occupational groups more effectively.
|
Received: 2020-09-03
Accepted: 2021-01-19
|
|
Corresponding Authors:
MAO Li
E-mail: limaochem@outlook.com
|
|
[1] Maltepe E, Er Elif Ö, Bakırdere S. Microchemical Journal, 2020, 158:105231.
[2] Xiao T F, Boyle D, Guha Jayanta, et al. Applied Geochemistry, 2003, 18(5): 675.
[3] Wojtkowiak T, Karbowska B, Zembrzuski W. Journal of Geochemical Exploration, 2016, 161: 42.
[4] Arıa B, Bakırdere S, Ataman O Y. Spectrochimica Acta Part B: Atomic Spectroscopy, 2020, 171:105937.
[5] John Petera A L, Viraraghavan T. Environment International, 2005, 31(4): 493.
[6] Wu M Y, Shu Y L, Song L L. Environment International, 2019, 129: 470.
[7] Karbowska B. Environmental Monitoring and Assessment, 2016, 188(11):640.
[8] Liu J, Luo X W, Wang I. Environmental Pollution, 2017, 224: 445.
[9] Sturini M, Maraschi F, Cucca L. Analytical Sciences, 2009, 25(1): 121.
[10] Krasnodebskaostrega B, Sadowska M, Piotrowska K. Talanta, 2013, 112: 73.
[11] Wang C L, Chen Y H, Pan J Y. Chinese Journal of Geochemistry, 2010, 29(1): 113.
[12] GBZ/T 300.1—2017. Determination of Toxic Substances in Workplace Air-Part 1: General Principles(工作场所空气有毒物质测定 第1部分: 总则). Beijing: Standards Press of China(北京: 中国标准出版社).
[13] GBZ/T 210.4—2008. Guide for Establishing Occupational Health Standards-Part 4: Determination Methods of Air Chemicals in Workplace(职业卫生标准制定指南 第4部分:工作场所空气中化学物质测定方法). Beijing: Standards Press of China(北京: 中国标准出版社). |
[1] |
GUO Xiao-hua1, ZHAO Peng1, WU Ya-qing1, TANG Xue-ping3, GENG Di2*, WENG Lian-jin2*. Application of XRF and ICP-MS in Elements Content Determinations of Tieguanyin of Anxi and Hua’an County, Fujian Province[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(10): 3124-3129. |
[2] |
ZHANG Fei1, 5,HUA Xia2*,YUAN Jia-ying3,YOU Fan1,YE Ren-cai4,DING Li4, ZHAO Jian-mei4. Determination of Thallium in Blood of Occupational Exposed Population by Inductively Coupled Plasma Mass Spectrometry With High Matrix Introduction[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(09): 2870-2874. |
[3] |
ZHAO Ting1,2,3, CHI Hai-tao1,2,3*, LIU Yi-ren1,2,3, GAO Xia1,2,3, HUANG Zhao1,2,3, ZHANG Mei1,2,3, LI Qin-mei1,2,3. Determination of Elements in Health Food by X-Ray Fluorescence Microanalysis Combined With Inductively Coupled Plasma Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(03): 750-754. |
[4] |
ZHOU An-li1, JIANG Jin-hua1, SUN Chun-xiao2, XU Xin-zhong2, LÜ Xin-ming1,2*. Identification of Different Origins of Hetian Jade Based on Statistical Methods of Multi-Element Content[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 3174-3178. |
[5] |
LIANG Piao-piao1, WANG Yi-run1, WANG Ru-ming1, FAN Li-yun1, CHEN Tian-tian1, BAI Ya-hong1, YU Qian-ru1, ZHOU Shan-shan1, LIU Ying1,2*. Level and Risk Assessment of Arsenic in Muti-Media near Mining Area in Yunnan by Using Inductively Coupled Plasma Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(03): 990-996. |
[6] |
LIANG Piao-piao1, XING Yun-xin1, WEI Chun-li1, LI Yuan-yuan1, LIU Yi-ming1, HU Yu1, LIU Ying1,2*. Distribution and Assessment of Heavy Metals in the Overlying Water-Sediment-Plant-Fish System in the Wuliangsuhai Lake by Using Inductively Coupled Plasma Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(02): 652-658. |
[7] |
WU Xiu-li1, ZHAO Zhi-zhong2, WU Dan2, CHEN Guang-ying3, LIU Hong1, HE Meng-xiong1, DING Guo-hua1, HE Wen-ying1*. Determination of Main Active Components and Metal Elements of Hainan Alpinia Katsumadai by Spectral Analysis [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(04): 1191-1196. |
[8] |
GAO Rui-feng1, 2, GAO Meng-chao3, LING Rui3, ZHANG Ning1* . Improving Analytical Methods by Uncertainty Evaluation with the Case of Determination of Aluminum in Starch Products by ICP-MS [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(04): 1211-1216. |
[9] |
WANG Xiao-wei1, LIU Jing-fu2, GUAN Hong3, WANG Xiao-yan1, SHAO Bing1*, ZHANG Jing1, LIU Li-ping1, ZHANG Ni-na1. Determination of Total Sulfur Dioxide in Chinese Herbal Medicines via Triple Quadrupole Inductively Coupled Plasma Mass Spectrometry [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(02): 527-531. |
[10] |
ZHAO Yan-fang, SHANG De-rong, ZHAI Yu-xiu*, NING Jin-song, DING Hai-yan, SHENG Xiao-feng . Application of ICP-MS to Detect Rare Earth Elements in Three Economic Macroalgaes in China [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(11): 3196-3199. |
[11] |
ZHANG Ping1, FU Liang2, XIE Hua-lin2* . Direct Determination of Heavy Metal Elements in Propolis by Inductively Coupled Plasma Mass Spectrometry [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(10): 2878-2881. |
[12] |
LI Zi-qiang, LI Xiao-ying, ZHU Kun, XU Xiao-xia, YAN Zhi-yuan . Research and Application of the ICP-MS Detection Technology for the Content of Nb and Ta in Geochemical Sample [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(08): 2303-2307. |
[13] |
ZHANG Ping1, FU Liang2*, NIE Xi-du1 . Determination of Si and P in MnZn Ferrites by Inductively Coupled Plasma Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(03): 808-811. |
[14] |
LI Tan-ping1, XIE Hua-lin2*. Determination of Impurity Elements in Edible Phosphate by ICP-MS [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(10): 2834-2837. |
[15] |
NIE Xi-du1,2, LIANG Yi-zeng1, FU Liang3, XIE Hua-lin3* . Direct Determination of Heavy Metal Elements in Sweeteners by Inductively Coupled Plasma Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(10): 2838-2841. |
|
|
|
|