An UV Imaging Methods Applicable to the Two-Dimensional Spatial Distribution of Pollutant Concentration |
ZHANG Ying-hua1, 2, 3, LI Ang1*, XIE Pin-hua1, XU Jin1,HU Zhao-kun1, WU Feng-cheng1,QIN Min1, FANG Wu1 |
1. Key Laboratory of Environmental Optics & Technology,Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
2. University of Science and Technology of China, Hefei 230026, China
3. Anhui Xinhua University, Hefei 230088, China |
|
|
Abstract A new type of ultraviolet imaging method is introduced, it is useful to specific pollution gas in the pollution sources. The method is based on Lambert-Bill absorption law and reproduces the two-dimensional distribution of pollutant concentration in space with high temporal and spatial resolution by using an ultraviolet band pass filter. The measurement system is built in the laboratory to detect SO2, the measuring method about imaging technology is set forth, and the linear response and sensitivity in regard to that is analyzed. The results show that the linear response is positive and the response coefficient is as high as 0.985. The sensitivity of different imaging area changes, the difference is between 1%~3%. At the same time, the accuracy of this method is discussed to get accurate SO2 column density, the result in the laboratory shows that the error about the method is around 1% and the accuracy is higher. At last, the detection limit of the method is analyzed and the space distribution of the target gas SO2 on cross section in the sample pool is parsed according to the linear least squares fitting method.
|
Received: 2017-05-16
Accepted: 2017-10-20
|
|
Corresponding Authors:
LI Ang
E-mail: angli@aiofm.ac.cn
|
|
[1] SUN You-wen, LIU Wen-qing, XIE Pin-hua(孙友文,刘文清,谢品华). Acta. Phys. Sin.(物理学报),2013, 62(1): 010701-1.
[2] Tamburello G, Kantzas E P, McGonigle A J S, et al. J. Volcanol. Geotherm. Res.,2011, 199: 47.
[3] Stebel K, Amigo A, Thomas H, et al. J. Volcanol. Geotherm. Res.,2015, 300: 112.
[4] Burton M R, Salerno G G, D’Auria L, et al. J. Volcanol. Geotherm. Res.,2015, 300: 95.
[5] Kern C, Kick F, Lubcke P, et al. Atoms. Meas. Tech., 2010, 3: 733.
[6] Gheorghe Catalin Nisulescu, Ioana Ionel, et al. Rev. Chim., 2012, 63(9): 940.
[7] Kern C, Werner C, Elias T, et al. J. Volcanol. Geotherm. Res.,2013, 262: 80.
[8] Prata A J. Atmos. Meas. Tech.,2014, 7: 1213.
[9] Emmanuel Dekemper, Jurgen Vanhamel, Bert Van Opstal, et al. Atmos. Meas. Tech., 2016, 9: 6025.
[10] Prata A J, Bernardo C. Atoms. Meas. Tech.,2014, 7: 2807.
[11] Platt U, Peter Lübcke, Jonas Kuhn, et al. J. Volcanol. Geotherm. Res.,2015, 300: 7.
[12] Kern C, Lübcke P, Bobrowski N, et al. J. Volcanol. Geotherm. Res.,2015, 300: 22.
[13] Kern C, Jeff Sutton, Tamar Elias, et al. J. Volcanol. Geotherm. Res.,2015, 300: 81.
[14] Robin Campion, Hugo Delgado-Granados, Toshiya Mori. J. Volcanol. Geotherm. Res.,2015, 300: 48.
[15] Lübcke P, Bobrowski N, Illing S, et al. Atmos. Meas. Tech., 2013, 6: 677. |
[1] |
XIONG Yuan-hui1, 2,LUO Zhong-jie1,CHEN Zhen-wei2, YU Guang-bao1, 2,DUAN Wei-min2, LIU Lin-mei2,LI Fa-quan2,WU Kui-jun2*. Study on Ultraviolet Imaging Remote Sensing Monitoring Technology for SO2 Gas Emission[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(04): 1289-1296. |
[2] |
WU Zi-yang1, 2, XIE Pin-hua1, 2, 3*, XU Jin2, LI Ang2, ZHANG Qiang1, 2, HU Zhao-kun2, LI Xiao-mei2, TIAN Xin1, 2. Study on the Distribution of NO2 Slant Column Density in Atmospheric Boundary Layer of Hefei City Based on Imaging Differential Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(03): 720-726. |
|
|
|
|