Research on Fuel-Dilution Monitoring of Engine Lubricant by UV Fluorescence
GONG Xiao-long1, TIAN Hong-xiang1*, SUN Yun-ling1, HE Wei1, LI Jing1, YANG Kun2
1. College of Power Engineering, Naval University of Engineering, Wuhan 430033, China
2. School of Energy Power Engineering, Wuhan University of Technology, Wuhan 430063, China
Abstract:Aiming at the condition monitoring problem of Diesel engine lubricating oil diluted by fuel, an experimental measuring apparatus was designed and completed to detect fluorescence intensity of oil samples by UV fluorometry. An UV LED with peak wavelength of 365 nm as emitting light source was chosen for exciting oil sample to produce fluorescence. Ultraviolet light from emitting light source passed through a 400 nm optical low pass filter and went into oil samples in quartz colorimetric utensil. Oil samples excited by ultraviolet light may produced fluorescent light. Firstly, fluorescent light was filtered by 400 nm optical high pass filter. And then filtered fluorescent light was transformed into electric signal by the photoelectric sensor with the detection wavelength range from 400 to 800 nm. After amplified by measurement circuit , digital multimeter can be used to detect the fluorescent light intensity. The signal amplification and measurement system were designed. The combination of optical high and low pass filters can reduce the interference of the ultraviolet light emitted by the ultraviolet light source to the fluorescence intensity of oil samples. Fluorescence intensity data of seven oil samples with different fuel concentrations of 20.3 Wt.%, 10.0 Wt.%, 5.0 Wt.%, 2.5 Wt.%, 1.5 Wt.%, 0.7 Wt.% and 0.0 Wt.% were obtained by the experimental apparatus as the above mentioned. The fitting equation of fuel concentration with fluorescence intensity was acquired. Finally, the oil sample of 7.5 Wt.% diesel oil content was used to verify the accuracy of the method. The fluorescence intensity of verifying oil sample was measured by the experimental apparatus. The ration of fuel to oil was calculated by fitting equation. The results showed that the ration of fuel to oil relative error between the calculated and the actual was 0.5%. The accurate measurement of the dilution of lubricating oil by fuel under the laboratory condition was realized.
龚小龙,田洪祥,孙云岭,何 伟,李 婧,杨 琨. 基于紫外荧光技术的柴油机润滑油被燃油稀释的检测研究[J]. 光谱学与光谱分析, 2017, 37(12): 3758-3762.
GONG Xiao-long, TIAN Hong-xiang, SUN Yun-ling, HE Wei, LI Jing, YANG Kun. Research on Fuel-Dilution Monitoring of Engine Lubricant by UV Fluorescence. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3758-3762.
[1] YANG Qi-ming,YAN Xin-ping, HE Shi-zhong, et al(杨其明,严新平,贺石中,等). Practical Technology of On-site Oil Monitoring Analysis(油液监测分析现场实用技术). Beijing: China Machine Press(北京:机械工业出版社),2006. 1.
[2] JIN Li-li, LI Gui-yun, ZHANG Bing-wu(金理力, 李桂云, 张丙伍). Lubricating Oil(润滑油), 2013,(6): 21.
[3] PANG Jin-shan, HE Shi-zhong, NING Cheng-yun, (庞晋山, 贺石中, 宁成云). Lubrication Engineering(润滑与密封), 2016, 41(12): 98.
[4] GONG Xiao-long, TIAN Hong-xiang, SUN Yun-ling, et al(龚小龙,田洪祥,孙云岭,等). Metrology & Measurement Technique(计量与测试技术), 2016, 43(6): 76.
[5] ASTM Standard D3524—04. Test Method for Diesel Fuel Dilution in Used Diesel Engine Oils by Gas Chromatography.
[6] WANG Ju-xiang, XING Zhi-na, HAN Xiao, et al(王菊香, 邢志娜, 韩 晓,等). Lubrication Engineering(润滑与密封), 2014, 39(8): 77.
[7] ASTM E2412—10. Standard Practice for Condition Monitoring of In-Service Lubricants by Trend Analysis Using Fourier Transform Infrared(FT-IR) Spectrometry.
[8] Macián V, Tormos B, Gómez Y A, et al. Tribology Transactions, 2012. 872.
[9] ZHANG Peng, LIU Hai-feng, YUE Zong-yu, et al(张 鹏,刘海峰,岳宗宇,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2015, 35(6): 1592.
[10] WANG Shu-tao, CUI Yan-yan(王书涛,崔彦彦). Infrared and Laser Engineering(红外与激光工程),2012, 41(3): 780.
[11] ZHAO Guang-li, FENG Wei-wei, FU Long-wen, et al(赵广立,冯魏巍,付龙文,等). Marine Science Bulletin(海洋通报),2014, 33(1): 77.
[12] XU Jin-gou, WANG Zun-ben(许金钩,王尊本). Fluorimetry(荧光分析法). Beijing: Science Press(科学出版社),2006. 4.