Study on the Method of Using ICP-MS to Determine Microelements in the Animal Feed
WANG Pei-long1, SU Xiao-ou1*, GAO Sheng1, WANG Tong1, ZHU Ruo-hua2
1. Institute of Quality Standards and Testing Technology for Agricultural Products, China Agricultural Academy of Science,Beijing 100081, China 2. Department of Chemistry, Capital Normal University, Beijing 100037, China
Abstract:The method for the determination of microelements such as Cu, Zn, Fe, Mn, Cr, Cd, Pb, As and Se in the animal feed by inductively coupled plasma-mass spectrometry was developed. The operation parameters, spectrum interference, matrix effect and memorial effect were studied in detail. Under optimal condition, the detection limits of these nine elements were from 2.03×10-3 to 3.17 μg·L-1, and the linear range was over three orders with a correlation coefficient above 0.999. This method was applied directly to determine microelements in real samples involving the standard wheat powder, formular feed and pre-mix feed. The determination results of microelements in the standard wheat powder accorded with reference results. The recovery of microelements in the formular feed was from 86% to 115%, and the relative standard deviations ≤8.2%(n=6). The results of elements content in the pre-mix feed were identical with those determined by national standard method. This method is simple, sensitive, accurate and can perform simultaneous multi-elements determination compared with conventional method of animal feed determination. The results were satisfactory.
王培龙1,苏晓鸥1*,高 生1,王 彤1,朱若华2 . 应用电感耦合等离子质谱测定饲料中的微量元素的研究[J]. 光谱学与光谱分析, 2007, 27(09): 1841-1844.
WANG Pei-long1, SU Xiao-ou1*, GAO Sheng1, WANG Tong1, ZHU Ruo-hua2. Study on the Method of Using ICP-MS to Determine Microelements in the Animal Feed. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(09): 1841-1844.
[1] Pu Xuli, Jiang Zucheng, Hu Bin. J. Anal. At. Spectrom., 2004, 19: 984. [2] Lü Lin-lin, XU Ye, YI Ping, et al(吕琳琳, 徐 烨, 伊 萍, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2006, 26(3): 548. [3] LIANG Pei, HU Bin, CHEN Hao, et al(梁 沛, 胡 斌, 陈 浩, 等). Chinese Journal of Spectroscopy Laboratory(光谱实验室). 2001, 18(4): 509. [4] TIE Mei, ZANG Shu-liang, ZHANG Wei, et al(铁 梅, 臧树良, 张 崴, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2006, 26(3): 551. [5] He Man, Hu Bin, Zeng Yan, et al. Journal of Alloys and Compounds, 2005, 390: 168. [6] YIN Ming, LI Bing, FU Ting-fa(尹 明, 李 冰, 符廷发). Journal of Analytical Science(分析科学学报), 1995, 11(1): 13. [7] HE Man, HU Bin, JIANG Zu-cheng(何 蔓, 胡 斌, 江祖成). Chemical Journal of Chinese Universities(高等学校化学学报), 2004, 25(12): 2232. [8] SHI Yu-feng, XIE Ming-yong, NIE Shao-ping,et al(施玉峰, 谢明勇, 聂少平, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2007, 27(2): 378. [9] TIAN Dong-mei, DENG Gui-chun, ZANG Shu-liang, et al(田冬梅, 邓桂春, 臧树良, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2006, 26(12): 2330. [10] HU Sheng-hong, WANG Xiu-ji, GE Wen, et al(胡圣虹, 王秀季, 葛 文, 等). Chinese Journal of Analytical Chemistry(分析化学), 2004, 32(9): 1139. [11] HU Sheng-hong, YANG Wei, SHUAI Qin, et al(胡圣虹, 杨 薇, 帅 琴, 等). Chemical Journal of Chinese Universities(高等学校化学学报), 2003, 24(1): 55. [12] XIONG Yi-jie, OUYANG Li, LIU Ya-qiong, et al(熊依杰, 欧阳荔, 刘雅琼, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2006, 26(11): 2120. [13] WANG Xiao-yi, HU W, Witkamp G T, et al(王小逸, HU W, Witkamp G T, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2003, 23(6): 1167. [14] LU Wen-wei, HU Ke. Modern Scientific Instruments(现代科学仪器), 2003,(1): 32. [15] LIU Xiao-li, ZHANG Hui-min, LIU Qi-fang, et al(刘小立, 张慧敏, 柳其芳,等). Journal of Hygiene Research(卫生研究), 2005, 34(2): 181.