Using Raman Spectroscopy for Determination Methanol Quantity in Illegal Alcoholic Beverages
Cem ZEREN1, Güneş AÇIKGÖZ2*, Süleyman KAHRAMAN3
1. Department of Forensic Medicine, Faculty of Medicine, Mustafa Kemal University, Hatay, Turkey
2. Hatay Vocational Health School of Health Services, Mustafa Kemal University, Hatay, Turkey
3. Department of Metallurgy and Material Engineering Faculty of Technology, Mustafa Kemal University, Hatay, Turkey
Using Raman Spectroscopy for Determination Methanol Quantity in Illegal Alcoholic Beverages
Cem ZEREN1, Güneş AÇIKGÖZ2*, Süleyman KAHRAMAN3
1. Department of Forensic Medicine, Faculty of Medicine, Mustafa Kemal University, Hatay, Turkey
2. Hatay Vocational Health School of Health Services, Mustafa Kemal University, Hatay, Turkey
3. Department of Metallurgy and Material Engineering Faculty of Technology, Mustafa Kemal University, Hatay, Turkey
摘要: Illegal production of alcoholic beverages is a common problem in most countries. The consumption of these counterfeit alcoholic products in Turkey has increasingly been one of the major health concerns. In this study, a comparison between GC-MS and Raman spectroscopy techniques was made to determine the amount of methanol in BogmaRaki which is a counterfeit alcoholic beverage produced and consumed in Hatay region. Different ratios of methanol/ethanol concentrations were prepared to obtain a calibration curve. This curve was used to measure the amount of methanol in the actual product samples using both GC-MS and Raman spectroscopy techniques. Results obtained from both techniques were compared using Paired sample t-tests. The Limit of Detection and the Limit of Quantification values were determined as 0.03 (%v/v) and 0.11 (%v/v), respectively. Both techniques demonstrated a similar sensitivity in the determination of methanol concentration in these counterfeit products (p>0.05). Raman Spectroscopy, however, has an advantage of being easy to use, inexpensive, rapid and non-destructive analytical technique with little or no sample preparation.
Abstract:Illegal production of alcoholic beverages is a common problem in most countries. The consumption of these counterfeit alcoholic products in Turkey has increasingly been one of the major health concerns. In this study, a comparison between GC-MS and Raman spectroscopy techniques was made to determine the amount of methanol in BogmaRaki which is a counterfeit alcoholic beverage produced and consumed in Hatay region. Different ratios of methanol/ethanol concentrations were prepared to obtain a calibration curve. This curve was used to measure the amount of methanol in the actual product samples using both GC-MS and Raman spectroscopy techniques. Results obtained from both techniques were compared using Paired sample t-tests. The Limit of Detection and the Limit of Quantification values were determined as 0.03 (%v/v) and 0.11 (%v/v), respectively. Both techniques demonstrated a similar sensitivity in the determination of methanol concentration in these counterfeit products (p>0.05). Raman Spectroscopy, however, has an advantage of being easy to use, inexpensive, rapid and non-destructive analytical technique with little or no sample preparation.
基金资助: There isn’t fund project and this issue was presented as a poster at the 7th European Academy of Forensic Science Conference, Prague, 2015
通讯作者:
Güneş AÇIKGÖZ
E-mail: gunesani@hotmail.com
引用本文:
Cem ZEREN, Güneş AÇIKGÖZ, Süleyman KAHRAMAN. Using Raman Spectroscopy for Determination Methanol Quantity in Illegal Alcoholic Beverages[J]. 光谱学与光谱分析, 2017, 37(09): 2979-2983.
Cem ZEREN, Güneş AÇIKGÖZ, Süleyman KAHRAMAN. Using Raman Spectroscopy for Determination Methanol Quantity in Illegal Alcoholic Beverages. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(09): 2979-2983.
[1] Rehm J, Mathers C, Popova S. Lancet,2009,373: 2223.
[2] Zeren C, Keten A, elik S, et al. J. Forensic. Leg. Med., 2013, 20(6): 706.
[3] The World Health Organization Global Status Report on Alcohol in 2014 (WHO, 2014).
[4] Lachenmeier D W, Kanteres F,Rehm J. Alcohol Clin. Exp. Res., 2014, 38(9): 2460.
[5] Rehm J, Kanteres F, Lachenmeier D W. Drug Alcohol Rev.,2010,29(4): 426.
[6] Zeren C, Aydin Z, Yonden Z, et al. Journal of Food Technology, 2012, 10(3): 87.
[7] Blakeney M. The Protection of Geographical Indications: Law and Practice. United Kingdom: Edward Elgar Publishing, 2014. 259.
[8] Türk Gda Kodeksi Distile Alkollü kiler Teblii (Tebli No: 2005/11). http://www.resmigazete.gov.tr/eskiler/2005/03/20050316-3.htm.
[9] Ashok P C, Praveen B B. Dholakia K Journal of Raman Spectroscopy,2013. doi: 10.1002/jrs.4301.
[10] Li Z, Deen M J, Kumar S, et al. Sensors,2014, 14: 17275,doi:10.3390/s140917275.
[11] Sikirzhytski V, Virkler K,Lednev I K. Sensors,2010, 10: 2869.
[12] Sikirzhytski V, Sikirzhytskaya A, Lednev I K. Applied Spectroscopy,doi: 10.1366/11-06455.
[13] Chalmers J M, Edwards H G M, Hargreaves M D. Vibrational Spectroscopy Techniques: Basics and Instrumentation-Infrared and Raman Spectroscopy in Forensic Science, John Wiley & Sons, Ltd, Chichester, UK,2012.
[14] Arslan M M, Zeren C, Aydin Z, et al. Journal of Forensic and Legal Medicine,2015, 33: 56.
[15] Shrivastava A, Gupta V B. Methods for the Determination of limit of detection and Limit of quantitation of the analytical methods. Chron Young Sci 2011 [cited 2015 May 8]; 2:21-5. Available from: http://www.cysonline.org/text.asp?2011/2/1/21/79345.
[16] Vaskova H. Quantitative Evaluation of Methanol Content in Beverages Based on Raman Spectral Data. Mathematics and Computers in Biology and Biomedical Informatics. ISBN: 978-960-474-333-9.
[17] Boyaci I H, Genis H E, Guven B, et al. J. Raman Spectrosc., 2012, 43: 1171.
[18] Picard A, Daniel I, Montagnac G, et al. Extremophiles, 2007, 11: 445.
[19] Fleger Y, Nagli L, Gaft M, et al. Journal of Luminescence, 2009, 129: 979.
[20] Lachenmeier D W, Sarsh B,Rehm J. Alcohol, 2009, 44(1): 93.