Peak Detection Algorithm of Optical Fiber SPR Signal Based on the Gaussian Fitting
ZHOU Peng1, 3, ZHANG Wen-bin1, WANG Jun-xing1, SUN Cui-ying1, LIU Jin1, 4, SU Rong-xin2, WANG Xue-min1, 3
1. School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China 2. School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China 3. Tianjin Key Laboratory of Biomedical Detection Technology and Instrumentation,Tianjin University,Tianjin 300072,China 4. State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072,China
Abstract:The spectrum of optical fiber surface plasmon resonance (SPR) shows the characteristics of wider full width at half-maximum (FWHM) and smaller peak value. The traditional peak detection algorithm cannot calculate the resonance wavelength of this kind of spectrum accurately. Therefore, efficient methods to calculate the resonance wavelength are required. This paper presents a method to process the SPR signal based on the Gaussian fitting. Combined with the trust region algorithm to determine the Gaussian fitting function, and then the resonance wavelength be calculated by line search method. Data processing of standard spectrum of glycerin with different concentration proves that this algorithm can adapt to optical fiber SPR spectrum characteristics, and calculate resonance wavelength accurately. The experiment measures the SPR signals of sucrose under different concentrations through the self-building SPR measure system. By using the proposed method, the weighted centroid method and the tracking centroid method to calculate the resonance wavelength, the result shows that the Gaussian fitting method can effectively improve resolution and have a short operation time which is conducive to engineering application.
Key words:Spectrum of SPR;The Gaussian fitting;Trust region algorithm;Peak detection
周 鹏1, 3,张文斌1,王军星1,孙翠迎1,刘 瑾1, 4,苏荣欣2,王学民1, 3. 基于高斯拟合的光纤型SPR信号的峰值检测算法[J]. 光谱学与光谱分析, 2016, 36(06): 1949-1953.
ZHOU Peng1, 3, ZHANG Wen-bin1, WANG Jun-xing1, SUN Cui-ying1, LIU Jin1, 4, SU Rong-xin2, WANG Xue-min1, 3. Peak Detection Algorithm of Optical Fiber SPR Signal Based on the Gaussian Fitting. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(06): 1949-1953.
[1] He P, Liu L, Qiao W, et al. Chemical Communications, 2014, 50(12): 1481. [2] Zeng S, Baillargeat D, Ho H P, et al. Chemical Society Reviews, 2014, 43(10): 3426. [3] Meneely J P, Elliott C T. World Mycotoxin Journal, 2014, 7(4): 491. [4] Raz S R, Leontaridou M, Bremer M G E G, et al. Analytical and Bioanalytical Chemistry, 2012, 403(10): 2843. [5] Shevchenko Y, Camci-Unal G, Cuttica D F, et al. Biosensors and Bioelectronics, 2014, 56: 359. [6] Bhatia P, Gupta B D. Applied Optics, 2011, 50(14): 2032. [7] Slavk R, Homola J, Brynda E. Biosensors and Bioelectronics, 2002, 17(6): 591. [8] Johansen K, Stlberg R, Lundstrm I, et al. Measurement Science and Technology, 2000, 11(11): 1630. [9] Nenninger G G, Piliarik M, Homola J. Measurement Science and Technology, 2002, 13(12): 2038. [10] Zhan S, Wang X, Liu Y. Measurement Science and Technology, 2011, 22(2): 025201. [11] Esmaeilzadeh H, Arzi E, Légaré F, et al. Sensors and Actuators A: Physical, 2015, 229: 8. [12] Willets K A, Van Duyne R P. Annu. Rev. Phys. Chem., 2007, 58: 267. [13] Srivastava S K, Verma R, Gupta B D. Sensors and Actuators B: Chemical, 2011, 153(1): 194. [14] Wang L, Xu L, Feng S, et al. Computers in Biology and Medicine, 2013, 43(11): 1661. [15] Nocedal J, Wright S. Numerical Optimization. Springer Science & Business Media, 2006. [16] XU Li-zhong, DING Xiao-feng, WANG Xin, et al (徐立中, 丁晓峰, 王 鑫, 等). Acta Electronica Sinica(电子学报), 2011, 39(3A): 24. [17] PENG Lei, LIU Li, LONG Teng, et al(彭 磊, 刘 莉, 龙 腾, 等). Chinese Journal of Mechanical Engineering(机械学报), 2011, 47(7): 164. [18] CHEN Shu-wang, WANG Jun-xing, SHENG Wei-nan, et al(陈书旺, 王军星, 盛伟楠, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2015, 35(4): 1124.