Research on Real-Time Trace Gas Detection System Based on QEPAS
MA Yu-fei1, 2, YU Guang1, ZHANG Jing-bo1, LUO Hao1, YU Xin1, YANG Chao-bo1, YANG Zhen1, SUN Rui2, CHEN De-ying1
1. Institute of Opto-electronics, Harbin Institute of Technology, Harbin 150001, China 2. Post-Doctoral Mobile Station of Power Engineering and Engineering Thermophysics, School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
Abstract:Quartz-enhanced photoacoustic spectroscopy (QEPAS) technology was invented lately. Therefore it’s an innovative method for trace gas detection compared with other existed technologies. In this paper, we studied the trace gas detection system based on QEPAS, and the atmospheric H2O was selected as the target analyte. In theory, the principles of laser wavelength modulation and signal harmonic detection were analyzed firstly, and the realizing solutions for the gas concentration retrieving and laser wavelength locking were obtained. Furthermore, the selection principle of absorption line for high sensitivity gas detection was discussed. In experiments, a continuous-wave distributed feedback(DFB) single mode diode laser emitting at 1.39 μm was used as the exciting source for the H2O vapor measurement. Using wavelength modulation spectroscopy and 2nd harmonic detection, the influence of laser wavelength modulation depth on QEPAS signal level was investigated, and the acoustic wave enhancement of the addition of micro-resonator in the acoustic detection module was analyzed as well. After optimization of the QEPAS system, a detection limit of 5.9 ppm for H2O vapor was obtained. We measured the H2O vapor with different concentrations, and the R-Square of 0.98 was achieved after the experimental data was linear fitted, indicated that the QEPAS system had an excellent linear response ability. Finally, continuous monitoring of atmospheric H2O concentration levels for a period of 12 hours was performed when the line locking mode was employed with the help of 3rd harmonic detection. The experimental results showed that this QEPAS scheme had a stable performance and outstanding continuous measuring capacity, and it can be widely used in high sensitivity on-line measurement for other trace gases detection fields.
马欲飞1, 2,于 光1,张静波1,罗 浩1,于 欣1,杨超博1,杨 振1,孙 锐2,陈德应1 . 基于石英增强光声光谱的痕量气体实时检测研究 [J]. 光谱学与光谱分析, 2015, 35(11): 3003-3006.
MA Yu-fei1, 2, YU Guang1, ZHANG Jing-bo1, LUO Hao1, YU Xin1, YANG Chao-bo1, YANG Zhen1, SUN Rui2, CHEN De-ying1. Research on Real-Time Trace Gas Detection System Based on QEPAS . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(11): 3003-3006.
[1] Ravishankara A R, Daniel J S, Portmann R W. Science, 2009, 326: 123. [2] Arslanov D D, Swinkels K, Cristescu S M, et al. Optics Express, 2011, 19: 24078. [3] Rapp D. The Mars Journal, 2006, 2: 72. [4] Ren W, Farooq A, Davidson D F, et al. Applied Physics B, 2012, 107: 849. [5] Khalil M A K, Rasmussen R A. Science, 1984, 224: 54. [6] Logan J A, Prather M J, Wofsy S C, et al. Journal of Geophysical Research-Atmospheres, 1981, 86: 7210. [7] Kosterev A A, Bakhirkin Y A, Curl R F, et al. Optics Letters, 2002, 27: 1902. [8] Dong L, Spagnolo V, Lewicki R, et al. Optics Express, 2012, 19: 24037. [9] Lewicki R, Wysocki G, Kosterev A A, et al. Optics Express, 2007, 15: 7357. [10] Chao X, Jeffries J B, Hanson R K. Applied Physics B, 2012, 106: 987. [11] Dong L, Kosterev A A, Thomazy D, et al. Applied Physics B, 2010, 100: 627. [12] Ma Y F, Lewicki R, Razeghi M, et al. Optics Express, 2013, 21: 1008.