Study on the Characteristics of the Imaging Spectrometer Calibration Using Diffuser Method
ZHANG Chun-lei1,2,XIANG Yang1*
1. State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China 2. Graduate University of Chinese Academy of Sciences, Beijing 100049, China
Abstract:Using a white diffuser to calibrate the imaging spectrometer has been a new technology developed to calibrate the imaging spectrometer recently. It has characteristics of easy realization and higher calibration accuracy. The expression of the collected signal electron number in each spectral channel of the imaging spectrometer detector pixels was deduced with the slit parallel and perpendicular to the meridional plane according to the principal of the calibration of imaging spectrometer using diffuser method in the present paper. The spectral radiometric calibration characteristics of the imaging spectrometer was numerically analyzed under the two special slit directions. The results indicate that the slit direction has significant effect on the spectral radiometric calibration of the imaging spectrometer. The signal electron number of the same spectral channel collected by the different scene pixels is different when the slit parallels to the meridional plane, and when the pixel is closer to the standard lamp, it collects more signal electrons;the signal electron number of the same spectral channel collected by the different scene pixels doesn’t change with the scene pixel position when the slit is perpendicular to the meridional plane.
张春雷1,2,向 阳1* . 漫反射板法定标成像光谱仪特性研究[J]. 光谱学与光谱分析, 2011, 31(01): 282-286.
ZHANG Chun-lei1,2,XIANG Yang1* . Study on the Characteristics of the Imaging Spectrometer Calibration Using Diffuser Method . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(01): 282-286.
[1] CUI Dun-jie(崔敦杰). Remote Sensing Technology and Application(遥感技术与应用),1996,11(3): 56. [2] LI Zhao-zhou, ZHENG Xiao-bing, TANG Ling-li(李照洲,郑晓兵,唐伶俐). Journal of Remote Sensing(遥感学报), 2007,11(4): 581. [3] Chrien T G, Green R O, Eastwood M L. SPIE, 1990, 1298: 37. [4] Zadnika J, Guerina D, Moss R, et al. SPIE, 2001,5425: 182. [5] Barnes R A, Eplee R E, Schmidt M, et al. Applied Optics, 2001, 40(36): 6682. [6] Davis C O, Kappus M, Bowles J, et al. SPIE, 1999, 3753: 160. [7] Davis C O, Bowles J, Leathers R A, et al. Optics Express, 2002, 10(4): 210. [8] Zhou Jiankang, JI Yiqun, Chen Yuheng, et al. SPIE, 2009, 7506: M1. [9] YANG Hua-yuan, CUI Dun-jie, REN Jian-wei(杨华元,崔敦杰, 任建伟). Acta Metrologica Sinica(计量学报),1998, 19(2): 123. [10] Folkman M, Peariman J, Liao L et al. SPIE, 2001, 4151: 40. [11] LI Tong-ji, CHEN Qing-lian(李铜基,陈清莲). Ocean Technology(海洋技术),2001,20(4): 26. [12] Jarecke P, Yokoyama K. SPIE, 2004, 4135: 254.