Spectroscopic Characteristics of DC Excited Atmospheric Pressure Glow Discharges Generated in a Needle-Plate Electrode Device and a Needle-Water Electrode One
LI Xue-chen, BAO Wen-ting, JIA Peng-ying, ZHAO Huan-huan, DI Cong
Key Laboratory of Photo-electronics Information Materials of Hebei Province, College of Physics Science and Technology, Hebei University, Baoding 071002, China
Abstract:Glow discharge characteristics in two discharge devices, i.e. in a needle-plate electrode geometry and a needle-water electrode one were compared by using spectroscopic method. Results show that the different emission regions were found in both discharges generated by the two devices. From the cathode to the anode, there are a cathode glow region, cathode dark glow, a positive column, and an anode glow region. The anode dark region can be clearly discerned in the glow discharge in the needle-plate electrode device, while it almost cannot be found in the needle-water electrode discharge. Comparing the current-voltage characteristics of the two glow discharges, it was found that the voltage across the electrodes decreases with increasing the discharge current in both discharge devices, while the voltage in the needle-water glow discharge is higher than that of the needle-plate one at the same current value. The current-voltage curves have a negative slope and their current densities lie in the range from 10-5 to 10-4 A?cm-2, which indicates that a normal glow discharge mechanism was involved in the two discharges. Comparing the optical spectra scanning from 300nm to 800nm and emitted from the whole normal glow discharge in the two electrode devices, similar spectral lines from the two discharges can be found on the optical emission spectrum, including the second positive system of nitrogen molecules (337.1nm) and the first negative system of nitrogen molecular ions (391.4nm). However, the intensity ratio of spectral lines is different. The intensity ratio (391.4nm to 337.1nm) and vibrational temperature were investigated at different locations. It was found that the intensity ratio of the needle-water electrode discharge is larger than that of the needle-plate electrode discharge at the same location. Furthermore, the vibrational temperature in the needle-water electrode discharge is higher than that of the needle-plate one at the same location.
Key words:Atmospheric pressure glow discharge;Optical emission spectrum;Vibrational temperature
李雪辰,鲍文婷,贾鹏英,赵欢欢,狄 聪 . 针-板和针-水电极大气压直流辉光放电的光谱特性 [J]. 光谱学与光谱分析, 2014, 34(01): 16-19.
LI Xue-chen, BAO Wen-ting, JIA Peng-ying, ZHAO Huan-huan, DI Cong . Spectroscopic Characteristics of DC Excited Atmospheric Pressure Glow Discharges Generated in a Needle-Plate Electrode Device and a Needle-Water Electrode One. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(01): 16-19.
[1] Raizer Y P. Gas Discharge Physics. Springer-Verlag, Berlin, 1987. [2] Iza F, Kim G J, Lee S M. Plasma Processes Polym.,2008,5:322. [3] Buntat Z, Smith I R,Razali N A M. J. Phys. D: Appl. Phys.,2009,42:235202. [4] Fridman G, Friedman G, Gutsol A. Plasma Process. Polym.,2008,5:503. [5] Kong M G, Kroesen G, Morfill G. New J. Phys.,2009 11:115012. [6] David Staack, Bakhtier Farouk, Alexander Gutsol. Plasma Sources Sci. Technol.,2005,14:700. [7] David Staack, Bakhtier Farouk, Alexander Gutsol. Plasma Sources Sci. Technol.,2008,17:025013. [8] Lu Xinpei, Mounir Laroussi. J. Phys. D: Appl. Phys., 2003, 36: 661-5. [9] Peter Bruggeman, Peter Guns, Joris Degroote. Plasma Sources Sci. Technol.,2008,17:045014. [10] Peter Bruggeman, Liu Jingjing, Joris Degroote. J. Phys. D: Appl. Phys.,2008,41:215201. [11] Verreycken T, Bruggeman P, Leys C. J. Appl. Phys.,2009,105:083312 [12] Gaisin A F. High Temperature, 2005,43(5):684. [13] Michael A Lieberman, Allan J Lichtenberg. Principles of Plasma Discharges and Materials Processing(等离子体放电原理与材料处理). Translated by PU Yi-kang(蒲以康,译). Beijing:People’s Education Press(北京:人民教育出版社), 2007. 413. [14] Jai Hyuk Choi, Tae Il Lee, Inho Han. Plasma Sources Sci. Technol.,2006,15:416. [15] Li Xuechen, Zhao Na, Fang Tongzhen. Plasma Sources Sci. Technol.,2008,17:015017.