Measurement of Relative Spectral Responsivity of Photodetector by LED-Based Spectrum-Tunable Source
LIU Hong-xing1,2 , REN Jian-wei1, WAN Zhi1, LIU Ze-xun1, LI Bao-yong1, YE Zhao1,2
1. Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China 2. Graduate University of Chinese Academy of Sciences, Beijing 100049, China
Abstract:A method of determining relative spectral responsivity of photodetector by LED-based spectrum-tunable integrating sphere source is put forward, and the measuring principle and algorithm are exhaustively described. In the course of calculation, the radiant transmission integral equation was changed into summation formula, and the degree of approximation between integral value and summation value is related to the selected wavelength interval. The differences between integral value and summation value in different wavelength intervals of Si photodiode and CCD were simulated and analyzed. The simulated results demonstrated that the relative differences between signal integral value and signal summation value of Si photodiode and CCD were below 0.2% in 10 nm interval, so 10 nm interval was an ideal choice. In the end, the factors affecting measurement accuracy were discussed and the solution suggestions were given. This method is easy in structure, and it avoids the measurement transmission errors of some instruments, such as monochromator.
[1] Palamer J M, Grant B G. The Art of Radiometry. Bellingham: SPIE Press. 2010. 127. [2] JIN Qi-wei, HU Wei-jie(金其伟,胡威捷). Radiometry, Photometry, Colorimetry Theory and Measurement(辐射度,光度与色度及其测量). Beijing: Beijing Institute of Technology Press(北京:北京理工大学出版社),2009. 74. [3] GB/T 26209—2010/CIE 64—1984. 2011. [4] Wall C F, Hanson A R, Taylor J A F. Proceedings of SPIE, 2001, 4295: 259. [5] YE Zhao, REN Jian-wei, LI Xian-sheng, et al(叶 钊,任建伟,李宪圣,等). Optics and Precision Engineering(光学精密工程), 2012, 20(1): 64. [6] DING Tian-ping, GUO Wei-ling, CUI Bi-feng, et al(丁天平,郭伟玲,崔碧峰,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2011, 31(6): 1450. [7] JIN Peng, YU Chun-yu, ZHOU Qi-feng, et al(金 鹏,喻春雨,周奇峰,等). Optics and Precision Engineering(光学精密工程), 2011, 19(1): 51. [8] WANG Yao, LIU Hua, JING Lei, et al(王 尧,刘 华,荆 雷,等). Optics and Precision Engineering(光学精密工程), 2012, 20(7): 1463. [9] Brown S W, Santana C, Eppeldauer G P. Res. Natl. Inst. Stand. Technol.,2002, 107(4): 363. [10] Fryc I, Brown S W, Eppeldauer G P,et al. Opt. Eng., 2005, 44(11): 111309. [11] CHEN Feng, YUAN Yin-lin, ZHENG Xiao-bing, et al(陈 风,袁银鳞,郑小兵,等). Optics and Precision Engineering(光学精密工程), 2008, 16(11): 2060. [12] LIU Hong-xing, REN Jian-wei, LI Bao-yong, et al(刘洪兴,任建伟,李葆勇,等). Chinese Journal of Luminescence(发光学报), 2011, 32(10): 1074. [13] LIU Hong-xing, SUN Jing-xu, LIU Ze-xun, et al(刘洪兴,孙景旭,刘则洵,等). Optics and Precision Engineering(光学精密工程), 2012, 20(7): 1447.