Abstract:The X-ray fluorescence well logging technology is a significant method that can make quantitative analysis orsemi-quantitative analysis on the wellface. This method is very important to mineral exploration. The spectrum shifting is often observed in the X-rayfluorescence well logging because the temperature in the well changes acutely. The hardware is used to release the spectrum shifting and the software method is used to rescale the tiny spectrum shifting. There are too manyspectra to be rescaled in a well logging task by manually. In this paper, an auto method to rescale spectrum shifting, via the expert system model which is based on the special process to rescale spectrum shifting in manual, is presented. The symmetric zero-area conversion method, which is not sensitive to the changes of the baseline, is used to research the peaks. And then, the characteristic peaks will be identified by the standard errors, automatically. The prior knowledge (the last energy scale) and the gauss probability density function are used to analyze the peaks qualitatively and confirm the energy of characteristic peaks. Then the least square method is applied energy calibration. The singular deviation point, away from the calibrationline, will be rejected and the energy ratio will be obtained again. This method is applied for rescaling spectrum shifting in 322 spectra and obtains a satisfactory achievement.
Key words:Rescaling spectrum shifting;X-ray fluorescence well logging;Expert system
张庆贤1,赵剑锟1,谷 懿1,葛良全1*,章小跃2,张 建1,王海东1,张 乐1 . X射线荧光测井谱漂校正技术研究 [J]. 光谱学与光谱分析, 2017, 37(03): 924-928.
ZHANG Qing-xian1, ZHAO Jian-kun1, GU Yi1, GE Liang-quan1*, ZHANG Xiao-yue2, ZHANG Jian1, WANG Hai-dong1, ZHANG Le1 . The Study of the Rescale Method of the Spectrum Shifting in X-Ray Fluorescence Well Logging. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(03): 924-928.
[1] X-RAY Detector. http://moxtek.com/xray-product/si-pin-x-ray-detectors/. 2016. 1. [2] CHEN Jian-zhen, GUO Lan-ying, LING Qiu, et al(陈坚祯, 郭兰英, 凌 球,等). Atomic Energy Science and Technology(原子能科学技术), 2005, 39(3): 266. [3] YANG De-xiang, LUO Yao-yao, GE Liang-quan, et al(杨德祥,罗耀耀,葛良全,等). Nuclear Electronics & Detection Technology(核电子学与探测技术), 2011, 31(6): 699. [4] GU Min, GE Liang-quan, YANG Feng(顾 民, 葛良全, 杨 峰). Nuclear Electronics & Detection Technology(核电子学与探测技术), 2010, 30(2): 293. [5] ZENG Guo-qiang, GE Liang-quan, XIONG Sheng-qing, et al(曾国强, 葛良全, 熊盛青,等). Nuclear Electronics & Detection Technology(核电子学与探测技术), 2010, 30(5): 699. [6] MAO Ben-jiang, ZHOU Rong-sheng, JIA Wen-peng(毛本将, 周蓉生, 贾文彭). Nuclear Techniques(核技术), 1995, 18(6): 364. [7] UO Yao-yao(罗耀耀). The Research on Stabilization for Airborne Gamma-ray Spectrometry System(航空伽马能谱稳谱技术研究). Chengdu: Chengdu University of Technology(成都: 成都理工大学),2005. [8] Pausch G, Stein J, Teofilov N. IEEE Transactions on Nuclear Science,2005, 52(5): 1849. [9] Samatov Z K, Stakhin A A, Fominykh V I. Instruments and Experimental Techniques,2007, 50(6): 772. [10] LI Xiao-li, GE Liang-quan, YANG Jia, et al(李晓丽,葛良全,杨 佳,等). Nuclear Electronics & Detection Technology(核电子学与探测技术), 2015, 35(5): 202. [11] LIN Yan-chang(林延畅). The Research on Multi-Element High-Sensitivity in-situ XRF Deteating System(高灵敏度多元素现场X荧光探测系统的研制). Chengdu: Chengdu University of Technology(成都: 成都理工大学),2006. [12] Jackson Peter. Introduction To Expert Systems (3ed). Addison Wesley, 1998. [13] PANG Ju-feng(庞巨丰). γ Spectrum Data Analysis(γ能谱数据分析). Xi’an: Shaanxi Science and Technology Press(西安: 陕西科学技术出版社), 1990. [14] Glenn F Knoll. RadiationDetection and Measurement(Fourth Edition). Weiley, 2010. [15] ZENG Guo-qiang, GE Liang-quan, LUO Yao-yao, et al(曾国强,葛良全,罗耀耀,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2013, 33(9): 2583.