Optimization Study of Non-Contact Color Measurement Parameters
WAN Xiao-xia1, FU Ma1, HUANG Xin-guo2, XIE Wei1, LI Jun-feng1, LIU Qiang1
1. School of Printing and Packaging, Wuhan University, Wuhan 430079, China 2. College of Packaging and Material,Hunan University of Technology,Zhuzhou 412008,China
Abstract:Spectral data or chrominance data acquired with color measurement device is able to objectively characterize the true color information of the object. As to the measuring target that without direct contact with the measuring instrument, it needs to adopt the non-contact color measurement method to obtain the color information.The spectral irradiance theoretical analysis shows that the changes of the color illumination distance, measuring distance and exposure time have greater impact on the measurement results. However, there is no in-depth study on the influence of the changes of measuring parameters for the measured results. In order to get the most accurate measurement results in the process of non-contact color measurement, parameter optimization study based on orthogonal experiment was proposed. Experiment with different combinations of parameters was conducted to obtain the color information of ColorChecker via PR705 spectroradiometer with range analysis and variance analysis method.Experimental results show that the minimum color difference of measured value and the standard value is 0.878 8ΔE, and the maximum color difference is 1.543 1ΔE. Data results show that the proposed method can effectively select the best combination of parameters, and to analyze the impact of various parameters on the result.
万晓霞1,付 马1,黄新国2,谢 伟1,李俊锋1,刘 强1 . 非接触式颜色测量参数的最优化研究 [J]. 光谱学与光谱分析, 2016, 36(09): 2889-2893.
WAN Xiao-xia1, FU Ma1, HUANG Xin-guo2, XIE Wei1, LI Jun-feng1, LIU Qiang1 . Optimization Study of Non-Contact Color Measurement Parameters . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(09): 2889-2893.
[1] Wyble D R, Rich D C. Color Research and Application, 2007, 32(3): 166. [2] Chorro Elísabet, Perales Esther, Navarro Victor, et al. Reproducibility Comparison Between Two Multi-Gonio-Spectrophotometers, in AIC 2009, Proceedings, 2009. [3] Berns R S, Zhao Y H, Taplin L A, et al. The Use of Spectral Imaging as an Analytical Tool for Art Conservation, Presented at the American Institute of Conservation Annual Meeting, 2009. [4] Cozzolino D, Cynkar W U, Dambergs R G, et al. Communications in Soil Science and Plant Analysis, 2013, 44: 1610. [5] GUO Yan, JI Wen-jun, WU Hong-hai, et al(郭 燕,纪文君,吴宏海,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2013, 33(4):1135. [6] Wee A G, Beatty M W, Gozalo-Diaz D J, et al. J. Prosthetic Dent, 2013, 22: 83. [7] Hasegawa Akira, Motonomi Akio, Ikeda Ikuo. Color Research and Application, 2000, 25(1):43. [8] Akira Hasegawa,Ikeda I, Kawaguchi S. Journal of Prosthetic Dentistry, 2000, 83(4): 418. [9] Wee Alvin G, Lindsey Delwin T, Kuo Shanglun. Dental Materials, 2006, 22(6); 553. [10] Gozalo-Diaz David J, Lindsey D T, Johnston W M, et al. J. Prosthetic Dent, 2007, 97(1): 45. [11] JIN Wei-qi, HU Wei-jie(金伟其,胡威捷). The Fundamental and Measurement of Radiometry, Photometry and Colorimetry(辐射度 光度与色度及其测量). Beijing: Beijing Institute of Technology Press(北京:北京理工大学出版社),2009. 7.