Abstract:In order to improve the precision and sensitivity of laser-induced breakdown spectroscopy device on detecting heavy metal, parameter optimization should be done. After selecting the initial delay time parameter in detecting navel orange experiment of laser-induced breakdown spectroscopy device, a cell range from 1.10 to 1.30 μs of delay time containing the initial parameter was extracted and experiment on it was conducted. There are more than one peak in the curve of element line intensity and signal-to-background ratio vs the delay time in the cell range, and the peak values are higher than the initial one. Confidence interval of the delay time calculated indirectly by interval estimation in Statistics is (1.13, 1.25]. The relative standard deviation decreases from 0.103 269 548 to 0.025 322 279 5 when the delay time adjusted from 1.20 to 1.14 μs in the confidence interval. It is suggested that parameters range of LIBS experimental device can be adjusted freely in the range while detecting measured elements so as to improve the precision and sensitivity.
Key words:Gannan navel;LIBS;heavy metal;Parameter range
林永增,姚明印*,刘木华,彭秋梅,张 旭,陈添兵,徐 媛 . LIBS装置检测赣南脐橙中Cu元素时的参数范围分析[J]. 光谱学与光谱分析, 2012, 32(11): 2925-2928.
LIN Yong-zeng, YAO Ming-yin*, LIU Mu-hua, PENG Qiu-mei, ZHANG Xu, CHEN Tian-bing, XU Yuan. Determination of Parameter Range in Detecting Cu of Gannan Navel Orange by LIBS Setup. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(11): 2925-2928.
[1] LU Cui-ping, LIU Wen-qing, ZHAO Nan-jing, et al(鲁翠萍,刘文清,赵南京,等). Chinese Journal of Lasers(中国激光), 2011, 48: 053002. [2] WANG Chun-long, LIU Jian-guo, ZHAO Nan-jing, et al(王春龙, 刘建国, 赵南京, 等). Chinese Journal of Lasers(中国激光), 2011, 38: 246. [3] JIANG Jie, LI Guan, LI Run-hua, et al(姜 杰, 李 关, 李润华, 等). High Power Laser and Particle Beams(强激光与粒子束), 2011, 23: 2528. [4] Jez Willian Batista Braga, Lilian Cristina Trevizan, Lidiane Cristina Nunes, et al. Spectrochimica Acta Part B,2010, 65: 66. [5] Cleon Barnett, Courtneé Bell, Komal Vig, et al. Anal. Bioanal. Chem., 2011, 10: 1007. [6] DONG Mei-rong, LU Ji-dong, LI Jun, et al(董美蓉,陆继东,李 军, 等). Acta Optica Sinica(光学学报), 2011, 31: 0130002. [7] CONG Zhi-bo, SUN Lan-xiang, XIN Yong, et al(丛智博, 孙兰香, 辛 勇, 等). Metallurgical Analysis, 2011, 31: 9. [8] LI Yong, LU Ji-dong, LIN Zhao-xiang, et al(李 勇,陆继东,林兆祥, 等). Journal of Applied Optics(应用光学),2008, 29: 1002. [9] WANG Chuan-hui, DAI Lin, ZHANG Xian-yi, et al(王传辉,戴 琳,张先燚,等). Chinese Journal of Lasers(中国激光),2006,33: 0258. [10] 美国NIST数据库.http://www.physics nist gov/PhysRef Data/ASD/lines-Form.html. [11] Chen Tianbing, Yao Mingyin, Liu Muhua, et al. Sensor Letters, 2012, 10: 1. [12] LI Peng-yan, XIE Cheng-li, LU Ji-dong, et al(李鹏艳,谢承利,陆继东, 等). Applied Laser(应用激光), 2009, 29: 22. [13] XU Yuan, YAO Ming-yin, LIU Mu-hua, et al(徐 媛,姚明印,刘木华, 等). Acta Optica Sinica(光学学报),2011, 31: 12300021. [14] CUI Zhi-feng, ZHANG Xian-yi, YAO Guan-xin, et al(崔执凤,张先燚,姚关心,等). Acta Physica Sinica(物理学报),2006, 55: 4506. [15] ZENG Wu-yi(曾五一). Statistics(统计学). Beijing: China Financial Publishing House(北京:中国金融出版社),2006.