光谱学与光谱分析 |
|
|
|
|
|
Automatic Assessment of Facial Nerve Function Based on Infrared Thermal Imaging |
LIU Xu-long1, 2, FU Bin-rui1, 2, XU Li-wen1, LU Ning2, YU Chang-yong2, BAI Lu-yi2 |
1. Department of Biomedical Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China 2. College of Information Science and Engineering, Northeastern University, Shenyang 110819, China |
|
|
Abstract Facial paralysis which is mainly caused by facial nerve dysfunction is a common clinical entity. It seriously devastates a patient’s daily life and interpersonal relationships. A method of automatic assessment of facial nerve function is of critical importance for the diagnosis and treatment of facial paralysis. The contralateral asymmetry of facial temperature distribution is one of the newly symptoms of facial paralysis patients which can be captured by infrared thermography. This paper presents a novel framework for objective measurement of facial paralysis based on the automatic analysis of infrared thermal image. Facial infrared thermal image is automatically divided into eight regional areas based on facial temperature distribution specificity and edge detection, the facial temperature distribution features are extracted automatically, including the asymmetry degree of facial temperature distribution, effective thermal area ratio and temperature difference. The automatic classifier is used to assess facial nerve function based on radial basis function neural network (RBFNN). This method comprehensively utilizes the correlation and specificity of the facial temperature distribution,extracts efficiently the facial temperature contralateral asymmetry of facial paralysis in the infrared thermal imaging. In our experiments, 390 infrared thermal images were collected from subjects with unilateral facial paralysis. The results show: the average classification accuracy rate of our proposed method was 94.10%. It has achieved a better classification rate which is above 9.31% than K nearest neighbor (kNN) classifier and 4.87% above Support vector machine (SVM). This experiment results is superior to traditional House-Brackmann facial neural function assessment method. The classification accuracy of facial nerve function with the method is full compliance with the clinical application standard. A complete set of automated techniques for the computerized assessment of thermal images has been developed to assess thermal dysfunction caused by facial paralysis, and the clinical diagnosis and treatment of facial paralysis also will benefit by this method.
|
Received: 2014-11-16
Accepted: 2015-03-15
|
|
Corresponding Authors:
LIU Xu-long
E-mail: liuxulong@neuq.edu.cn
|
|
[1] Holland N J, Weiner G M. BMJ, 2004, 329(7465): 553. [2] Chan J Y K, Byrne P J. Facial Plastic Surgery, 2011, 27(4): 346. [3] Lamina S, Hanif S. African Health Sciences, 2013, 12(4): 514. [4] Henstrom D K, Skilbeck C J, Weinberg J, et al. The Laryngoscope, 2011, 121(1): 47. [5] Lee H Y, Park M S, Byun J Y, et al. Clinical and Experimental Otorhinolaryngology, 2013, 6(3): 135. [6] Wachtman G S, Cohn J F, VanSwearingen J M, et al. Plastic and Reconstructive Surgery, 2001, 107(5): 1124. [7] Mitre E I, Lazarini P R, Dolci J E L. American Journal of Otolaryngology, 2008, 29(1): 51. [8] He S, Soraghan J J, O’Reilly B F. EURASIP J Image Video Process, 2007, 2007(4): 81282. [9] He S, Soraghan J J, O’Reilly B F, et al. IEEE Trans. Biomed. Eng., 2009, 56(7): 1864. [10] GAO Yu-hong, XUE Yi-long, LUO Yun, et al(高宇红, 薛毅珑, 罗 芸, 等). Chinese Journal of Laser Medicine & Surgery(中国激光医学杂志), 2008, 17(1): 50. [11] Zhang D. The American Journal of Chinese Medicine, 2007, 35(6): 967. [12] LIU Xu-long, HONG Wen-xue, ZHANG Tao, et al(刘旭龙, 洪文学, 张 涛, 等). Journal of Biomedical Engineering(生物医学工程学杂志), 2013, 30(1): 34. [13] Nosaka R, Fukui K. Pattern Recognition, 2014, 47(7): 2428. [14] Luqman H, Mahmoud S A, Awaida S. Pattern Recognition, 2014, 47(6): 2231. [15] O’Reilly B F, Soraghan J J, McGrenary S, et al. Otology & Neurotology, 2010, 31(3): 486. |
[1] |
ZHANG Ning-chao1, YE Xin1, LI Duo1, XIE Meng-qi1, WANG Peng1, LIU Fu-sheng2, CHAO Hong-xiao3*. Application of Combinatorial Optimization in Shock Temperature
Inversion[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3666-3673. |
[2] |
LIANG Ya-quan1, PENG Wu-di1, LIU Qi1, LIU Qiang2, CHEN Li1, CHEN Zhi-li1*. Analysis of Acetonitrile Pool Fire Combustion Field and Quantitative
Inversion Study of Its Characteristic Product Concentrations[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3690-3699. |
[3] |
LI Xiao-dian1, TANG Nian1, ZHANG Man-jun1, SUN Dong-wei1, HE Shu-kai2, WANG Xian-zhong2, 3, ZENG Xiao-zhe2*, WANG Xing-hui2, LIU Xi-ya2. Infrared Spectral Characteristics and Mixing Ratio Detection Method of a New Environmentally Friendly Insulating Gas C5-PFK[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3794-3801. |
[4] |
CHEN Heng-jie, FANG Wang, ZHANG Jia-wei. Accurate Semi-Empirical Potential Energy Function, Ro-Vibrational Spectrum and the Effect of Temperature and Pressure for 12C16O[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3380-3388. |
[5] |
YU Hao-zhang, WANG Fei-fan, ZHAO Jian-xun, WANG Sui-kai, HE Shou-jie*, LI Qing. Optical Characteristics of Trichel Pulse Discharge With Needle Plate
Electrode[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(10): 3041-3046. |
[6] |
CHENG Hong1, YAN Ding-ce1*, WU Li-qing2, XU Jun3. Spectral Magnitude Uncertainty in Measurement of Protein Circular
Dichroism Spectra—An Empirical Study on Cytochrome C[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(10): 3105-3110. |
[7] |
TIAN Fu-chao1, CHEN Lei2*, PEI Huan2, BAI Jie-qi1, ZENG Wen2. Diagnosis of Emission Spectroscopy of Helium, Methane and Air Plasma Jets at Atmospheric Pressure[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2694-2698. |
[8] |
ZENG Si-xian1, REN Xin1, HE Hao-xuan1, NIE Wei1, 2*. Influence Analysis of Spectral Line-Shape Models on Spectral Diagnoses Under High-Temperature Conditions[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2715-2721. |
[9] |
LI Chang-ming1, CHEN An-min2*, GAO Xun3*, JIN Ming-xing2. Spatially Resolved Laser-Induced Plasma Spectroscopy Under Different Sample Temperatures[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(07): 2032-2036. |
[10] |
LIANG Wen-ke, WEI Guang-fen, WANG Ming-hao. Research on Methane Detection Error Caused by Lorentzian Profile Approximation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1683-1689. |
[11] |
WANG Pei-qi, CHENG Xiao-fang*, ZHANG De-bin. Radiation Thermometry Method Based on Intersection Capture of Spectral Distribution Curves[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1676-1682. |
[12] |
LIU Si-ran1, GONG Xin1, YAN Bi-chen2. Determining the Firing Temperature of Ancient Ceramics With FTIR Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1495-1500. |
[13] |
ZHANG Li-fang1, YANG Yan-xia1, ZHAO Guan-jia1, MA Su-xia1, GUO Xue-mao2. Comparison of Numerical Iterative Algorithms for Two-Dimensional Absorption Spectral Reconstruction[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1367-1375. |
[14] |
LIU Rong1, 2, WANG Miao-miao1, 2 , SUN Ze-yu1, 2, CHEN Wen-liang1, 2, LI Chen-xi2*, XU Ke-xin1, 2. Research on Temperature Disturbance of Glucose Solution With
Two-Trace Two-Dimensional Correlation Spectrum Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1051-1055. |
[15] |
CHEN Feng-yi, ZHANG Yu-gui*, WANG Wei-gang, XU Peng-mei. Research on Asteroid Surface Temperature Inversion Method Based on Wide Wavelength Band Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1162-1167. |
|
|
|
|